《ASTM A697 A697M-2013 Standard Test Method for Alternating Current Magnetic Properties of Laminated Core Specimen Using Voltmeter-Ammeter-Wattmeter Methods《伏特计-安培计-瓦特计测定叠层铁芯样品交流电磁特性.pdf》由会员分享,可在线阅读,更多相关《ASTM A697 A697M-2013 Standard Test Method for Alternating Current Magnetic Properties of Laminated Core Specimen Using Voltmeter-Ammeter-Wattmeter Methods《伏特计-安培计-瓦特计测定叠层铁芯样品交流电磁特性.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A697/A697M 03 (Reapproved 2008)A697/A697M 13Standard Test Method forAlternating Current Magnetic Properties of Laminated CoreSpecimen Using Voltmeter-Ammeter-Wattmeter Methods1This standard is issued under the fixed designation A697/A697M; the number immediately following the designatio
2、n indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determin
3、ation of several ac magnetic properties of laminated cores made from flat-rolledmagnetic materials.1.2 This test method covers test equipment and procedures for the determination of impedance permeability and exciting powerfrom voltage and current measurements, and core loss from wattmeter measureme
4、nts. These tests are made under conditions ofsinusoidal flux.1.3 This test method covers tests for two general categories (1 and 2) of cores based on size and application.1.4 Tests are provided for power and control size cores (Category 1) operating at inductions of 10 to 15 kG 1.0 to 1.5 T andat fr
5、equencies of 50, 60, and 400 Hz.1.5 Procedures and tests are provided for coupling and matching type transformer cores (Category 2) over the range ofinductions from 100 G 0.01 T or lower to 10 kG 1.0 T and above at 50 to 60 Hz or above when covered by suitable procurementspecifications.1.6 This test
6、 method also covers tests for core loss and ac impedance permeability under incremental test conditions (acmagnetization superimposed on dc magnetization) for the above core types and at inductions up to those that cause the ac excitingcurrent to become excessively distorted or reach values that exc
7、eed the limits of the individual test equipment components.1.7 This test method shall be used in conjunction with Practice A34/A34M and Terminology A340. It depends upon thesedesignated documents and a related reference test manual for detailed information which will not be repeated in this test met
8、hod.1.8 The values and equations stated in customary (cgs-emu and inch-pound) or SI units are to be regarded separately asstandard. Within this standard, SI units are shown in brackets. The values stated in each system may not be exact equivalents;therefore, each system shall be used independently o
9、f the other. Combining values from the two systems may result innonconformance with this standard.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health
10、 practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A34/A34M Practice for Sampling and Procurement Testing of Magnetic MaterialsA340 Terminology of Symbols and Definitions Relating to Magnetic Testing3. Terminology3.1 The terms
11、and symbols listed below apply only to this test method. The official list of symbols and definitions may be foundin Terminology A340.3.2 Symbols:1 This test method is under the jurisdiction of ASTM Committee A06 on Magnetic Properties and is the direct responsibility of Subcommittee A06.01 on Test
12、Methods.Current edition approved Nov. 1, 2008Nov. 1, 2013. Published December 2008November 2013. Originally approved in 1974. Last previous edition approved in 20032008as A697/A697M 03.A697/A697M 03 (2008). DOI: 10.1520/A0697_A0697M-03R08. 10.1520/A0697_A0697M-13.2 For referencedASTM standards, visi
13、t theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. ForAnnual Book ofASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard
14、an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is
15、to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1As = E lamination surface area, one side only,Ass = EI lamination surface area, one side only,h = lamination stack height,Adc = dc ammeter,Idc = dc
16、 current,N1 = primary turns,N2 = secondary turns,N3 = tertiary turns,R1 = ammeter shunt resistance,Vf = flux voltmeter,w = lamination center leg width,W = wattmeter, andZ = choke coil impedance.4. Summary of Test Method4.1 For Category 1 cores, the recommended tests are made at a frequency of 60 Hz
17、and at a test induction within the range from10 through 15 kG 1.0 to 1.5 T.4.2 For Category 2 cores, the recommended tests are made at a frequency of 50 or 60 Hz and at inductions of 40, 100 or 200,2000, 5000, 6000, 7000, and 10 000 G 0.004, 0.01 or 0.02, 0.2, 0.5, 0.6, 0.7, and 1.0 T. Any or all ma
18、y be required dependingon the type of core material.5. Significance and Use5.1 This test method was developed for evaluating the ac magnetic properties of laminated cores made from flat-rolled magneticmaterials.5.2 The reproducibility and repeatability of this test method are such that this test met
19、hod is suitable for design, specificationacceptance, service evaluation, and research and development.6. Apparatus6.1 The apparatus for testing under this test method shall consist of as many of the following components, described in 6.2through 6.12, as required to perform the desired test measureme
20、nts.6.2 Test CoilsIn general, test coils are designed to surround a square center leg stack (lamination stack height equal to centerleg width). They consist of two or more windings with the secondary wound on the coil form first. Three groups of standard testcoils are described in 6.2.1 through 6.2.
21、3. Each of these has been designed to provide specific features during test. Because of turns,coil resistance, and magnitude of induced voltage, each has a particular field of application.6.2.1 The coils listed in Table 1, for testing Category 1 cores, have been designed to have equal primary and se
22、condary turnsand provide an induced voltage of 115 V when operating at a peak flux density of 15 kG 1.5 T at 60 Hz.6.2.2 The coils listed in Table 2, for testing Category 2 cores, have been designed to have characteristics that provide a directreadout capability for incremental permeability. The tes
23、t coil is designed so that the primary winding 22.N15100=2 pi l1, thesecondary winding N2 = 20 l1, and the tertiary winding N3 is designed so that the N 355=2 pi l1 (and N1/N3 = 20).6.2.3 The coils listed in Table 3 have been designed for testing Category 1 cores at a frequency of 400 Hz.6.3 Flux Vo
24、ltmeterThe flux voltmeter shall be a true average responsive voltmeter calibrated to read =2 pi/4 times the fullwave rectified average voltage so that its indications will be identical to those of a true rms voltmeter on a pure sinusoidal voltage.To produce the estimated precision of tests under thi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA697A697M2013STANDARDTESTMETHODFORALTERNATINGCURRENTMAGNETICPROPERTIESOFLAMINATEDCORESPECIMENUSINGVOLTMETERAMMETERWATTMETERMETHODS

链接地址:http://www.mydoc123.com/p-459197.html