1、Designation: A 435/A 435M 90 (Reapproved 2007)Standard Specification forStraight-Beam Ultrasonic Examination of Steel Plates1This standard is issued under the fixed designation A 435/A 435M; the number immediately following the designation indicates the yearof original adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification2covers the procedure and acceptancestandards for straight-beam, pulse-echo, ul
3、trasonic examina-tion of rolled fully killed carbon and alloy steel plates,12 in.12.5 mm and over in thickness. It was developed to assuredelivery of steel plates free of gross internal discontinuitiessuch as pipe, ruptures, or laminations and is to be usedwhenever the inquiry, contract, order, or s
4、pecification statesthat the plates are to be subjected to ultrasonic examination.1.2 Individuals performing examinations in accordance withthis specification shall be qualified and certified in accordancewith the requirements of the latest edition of ASNT SNT-TC-1A or an equivalent accepted standard
5、. An equivalentstandard is one which covers the qualification and certificationof ultrasonic nondestructive examination candidates and whichis acceptable to the purchaser.1.3 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI uni
6、ts are shown in brackets. The values stated in eachsystem are not exact equivalents, therefore, each system mustbe used independently of the other. Combining values from thetwo systems may result in nonconformance with the specifi-cation.2. Referenced Documents2.1 ASNT Documents:3ASNT SNT-TC-1A Reco
7、mmended Practice for PersonnelQualification and Certification in Nondestructive Testing3. Apparatus3.1 The manufacturer shall furnish suitable ultrasonicequipment and qualified personnel necessary for performingthe test. The equipment shall be of the pulse-echo straight beamtype. The transducer is n
8、ormally 1 to 118 in. 25 to 30 mm indiameter or 1 in. 25 mm square; however, any transducerhaving a minimum active area of 0.7 in.2450 mm2 may beused. The test shall be performed by one of the followingmethods: direct contact, immersion, or liquid column coupling.3.2 Other search units may be used fo
9、r evaluating andpinpointing indications.4. Test Conditions4.1 Conduct the examination in an area free of operationsthat interfere with proper functioning of the equipment.4.2 Clean and smooth the plate surface sufficiently tomaintain a reference back reflection from the opposite side ofthe plate at
10、least 50 % of the full scale during scanning.4.3 The surface of plates inspected by this method may beexpected to contain a residue of oil or rust or both. Anyspecified identification which is removed when grinding toachieve proper surface smoothness shall be restored.5. Procedure5.1 Ultrasonic exam
11、ination shall be made on either majorsurface of the plate. Acceptance of defects in close proximitymay require inspection from the second major surface. Platesordered in the quenched and tempered condition shall be testedfollowing heat treatment.5.2 A nominal test frequency of 214 MHz is recommended
12、.Thickness, grain size, or microstructure of the material andnature of the equipment or method may require a higher orlower test frequency. However, frequencies less than 1 MHzmay be used only on agreement with the purchaser. A clear,easily interpreted trace pattern should be produced during theexam
13、ination.5.3 Conduct the examination with a test frequency andinstrument adjustment that will produce a minimum 50 to amaximum 75 % of full scale reference back reflection from theopposite side of a sound area of the plate. While calibrating theinstrument, sweep the crystal along the plate surface fo
14、r adistance of at least 1T or 6 in. 150 mm, whichever is thegreater, and note the position of the back reflection. A shift inlocation of the back reflection during calibration shall be causefor recalibration of the instrument.1This specification is under the jurisdiction of ASTM Committee A01 on Ste
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA435A435M19902007STANDARDSPECIFICATIONFORSTRAIGHTBEAMULTRASONICEXAMINATIONOFSTEELPLATES 钢板 直射 纵向

链接地址:http://www.mydoc123.com/p-458343.html