ASSE 1063-2008 Performance Requirements for Air Valve and Vent Inflow Preventer.pdf
《ASSE 1063-2008 Performance Requirements for Air Valve and Vent Inflow Preventer.pdf》由会员分享,可在线阅读,更多相关《ASSE 1063-2008 Performance Requirements for Air Valve and Vent Inflow Preventer.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、Performance Requirements for Air Valve and Vent Inflow Preventer American Society of Sanitary EngineeringASSE Standard #1063-2008ASSE Board Approved: February 20, 2008ANSI Approved: October, 2009An American National StandardAir Valve and Vent Inflow Preventer IASSE Standard #1063 - 2008American Soci
2、ety of Sanitary EngineeringWestlake, OhioCopyright 2008Neither this standard, nor any portion thereof, may be reproduced without the written consent of the American Society of Sanitary Engineering.No product may be said to be ASSE approved unless the manufacturer has applied to the ASSE, has had the
3、 product tested by an official ASSE recognized independent laboratory, according to the applicable ASSE Standard, passed the test, and has been reviewed and approved by the consensus ASSE Seal Control Board. Having completed the aforementioned, the manufacturer may then display the ASSE Seal on the
4、product.Instructions for receiving the authorization to display the Seal are available from the ASSE International Office. Organizations wishing to adopt or list any ASSE Standard should print the ASSE Standard Number on the cover page first and in equal or larger type to that of the adopting or lis
5、ting organization.General InformationII Air Valve and Vent Inflow PreventerASSE Standard #1063 - 2008Air Valve and Vent Inflow Preventer IIIASSE Standard #1063 - 2008This foreword shall not be considered a part of the standard, however, it is offered to provide background information.ASSE Standards
6、are developed in the interest of consumer safety.Water distribution systems are equipped with air valves and air vents at multiple locations to release and admit air into pipelines and reservoirs to allow filling and draining, control surges, and maintain flow efficiency. If the valve or reservoir o
7、utlets become flooded or are the target of malicious tampering, the air entry point may be compromised and allow the entry of floodwater or the intentional introduction of a contaminate to the water system. The Air Valve and Vent Inflow Preventer is directly connected to air valve outlets and reserv
8、oir vent pipes. This device is normally open to allow unrestricted airflow in and out of pipelines and reservoirs during normal conditions. When a flood occurs, a float-operated closure member automatically closes to prevent the entry of contaminated fluids. A redundant, float-operated closure membe
9、r automatically closes if the first one fails. The device is mounted in or near air valve vaults or reservoir vents. Recognition is made of the time volunteered by members of the working group and of the support of the manufacturers who also participated in the meetings for this standard.This standa
10、rd does not imply ASSEs endorsement of a product which conforms to these requirements.Compliance with this standard does not imply acceptance by any code body.This standard was promulgated in accordance with procedures developed by the American National Standards Institute (ANSI).ForewordIV Air Valv
11、e and Vent Inflow PreventerASSE Standard #1063 - 2008Edward LyczkoProduct Standards Committee ChairmanCleveland ClinicCleveland, OhioRand H. AckroydRand EngineeringNewburyport, MassachusettsMichael BeckwithState of Wisconsin Department of CommerceMadison, WisconsinGunnar O. CollinsCollins Backflow S
12、pecialists, Inc.Palatine, IllinoisJudson W. CollinsJULYCO ProfessionalsMannford, OklahomaShannon M. Corcoran ASSE Standards CoordinatorWestlake, OhioA. Richard EmmersonGeneral InterestBuffalo Grove, IllinoisCharles GrossInternational Association of Plumbingand Mechanical OfficialsWalnut, CaliforniaS
13、teven HazzardASSE Staff EngineerWestlake, Ohio2008-2009 Product Standards Committee John F. Higdon, P.E.Apollo Valves/Conbraco Industries, Inc.Pageland, South CarolinaValentine Lehr, P.E.Lehr AssociatesNew York, New YorkChuck LottPrecision Plumbing Products, Inc.Portland, OregonPeter MarzecUnited As
14、sociation ofPlumbers and PipefittersWashington, D.C.Brad NollWilkins, A Division of Zurn Industries, Inc.Paso Robles, CaliforniaThomas C. Pitcherello State of New JerseyBordentown, New JerseyShabbir RawalpindiwalaKohler CompanyKohler, WisconsinTsan-Liang Su, Ph.D.Center for Environmental SystemsStev
15、ens Institute of TechnologyHoboken, New JerseyJoseph C. Zaffuto, P.E.ASSE Staff EngineerWestlake, OhioAir Valve and Vent Inflow Preventer VASSE Standard #1063 - 2008Ahtu AsoKMK Consultants LimitedBrampton, Ontario, CanadaJohn BallumValmatic CorporationElmhurst, IllinoisSteven HazzardASSE Staff Engin
16、eerWestlake, OhioKenneth J. KerrKerr MarketingBrunswick, Ohio Phillip LandonValmatic CorporationElmhurst, Illinois1063 Working GroupVI Air Valve and Vent Inflow PreventerASSE Standard #1063 - 2008Table of ContentsSection I 11.0 General . 11.1 Application 11.2 Scope . 11.3 Limitations on Design . 1Ta
17、ble 1 2Table 2 2Table 3 31.4 Reference Standards 3Section II . 42.0 Test Specimens 42.1 Samples Submitted 42.2 Samples Tested 42.3 Drawings . 42.4 Rejection . 4Section III 53.0 Performance Requirements and Compliance Testing 53.1 Hydrostatic Testing of Complete Device . 5Figure 1 53.2 Water Tightnes
18、s Test of Float-Operated Checks 5Figure 2 63.3 Allowable Pressure Loss at Rated Air Flow 6Figure 3 73.4 Vacuum Flow Test . 7Figure 4 8Section IV . 94.0 Detailed Requirements . 94.1 Materials . 94.2 Documentation . 94.3 Markings . 10Section V 115.0 Definitions . 11Appendix A . 12A1.0 Recommended Inst
19、allation Guidelines 12A1.1 General 12A1.2 Orientation . 12A1.3 Clearances 12Air Valve and Vent Inflow Preventer 1ASSE Standard #1063 - 2008Air Valve and Vent Inflow PreventerSection I1.0 General 1.1 ApplicationThe purpose of Air Valve and Vent Inflow Preventer Assemblies (herein after referred to as
20、 the “assembly”) is to allow the release and admission of high volumes of air through air valves and air vents in water distribution systems but prevent the entry of contaminated water when the air valve outlet becomes submerged from flooding or is the target of malicious tampering.1.2 Scope1.2.1 De
21、scriptionThis assembly shall consist of a primary and a secondary chamber. Each chamber shall contain an independent float-operated closure member. The primary chamber is the lower chamber. The secondary or upper chamber is redundant and will close in the event the primary chamber fails to close. Ot
22、her configurations achieving the perfor-mance requirements of this standard are acceptable.1.2.2 Size Range and ConnectionsSizes 1 to 4 NPS (25 to 100 mm) shall be furnished with an NPTF threaded connection. Sizes 6 to 16 NPS (150 to 400 mm) shall be furnished with a flanged connection.1.2.3 Pressur
23、e RangeThe assembly shall be designed and constructed for an operating pressure range of 9.7 psia (66.9 kPaabsolute) to 25.0 psi (172.4 kPa).1.2.4 Temperature RangeThe assembly shall function at temperatures from 32.0 F to 150.0 F (0 C to 65.6 C).1.3 Limitations on Design1.3.1 Flow Design Flow ways
24、through the entire assembly passage-way shall be as follows:a) The least cross-sectional area of the air flow ways, including the seat areas, shall not be less than the inside cross-sectional area of the same NPS.b) The manufacturer shall furnish a sectional print of the assembly with all of the dim
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASSE10632008PERFORMANCEREQUIREMENTSFORAIRVALVEANDVENTINFLOWPREVENTERPDF

链接地址:http://www.mydoc123.com/p-457124.html