ANSI UL 60730-2-12-2017 UL Standard for Safety Automatic Electrical Controls C Part 2-12 Particular Requirements for Electrically Operated Door Locks (Third Edition).pdf
《ANSI UL 60730-2-12-2017 UL Standard for Safety Automatic Electrical Controls C Part 2-12 Particular Requirements for Electrically Operated Door Locks (Third Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 60730-2-12-2017 UL Standard for Safety Automatic Electrical Controls C Part 2-12 Particular Requirements for Electrically Operated Door Locks (Third Edition).pdf(37页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60730-2-12 Automatic Electrical Controls Part 2-12: Particular Requirements for Electrically Operated Door Locks STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODU
2、CTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Automatic Electrical Controls Part 2-12: Particular Requirements for Electrically Operated Door Locks, UL 60730-2-12 T
3、hird Edition, Dated May 11, 2017 Summary of Topics UL 60730-2-12 is an adoption of the third edition of IEC 60730-2-12 with national differences. This new edition dated May 11, 2017 was issued to reect the latest approval date as an American National Standard that was proposed February 10, 2017. The
4、 requirements are substantially in accordance with Proposal(s) on this subject dated February 10, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherw
5、ise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, i
6、ndirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for
7、 any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable
8、 attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MAY 11, 2017 UL 60730-2-12 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 11, 2017
9、 UL 60730-2-12 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL May 11, 2017 1 UL 60730-2-12 Standard for Automatic Electrical Controls Part 2-12: Particular Requirements for Electrically Operated Door Locks Prior to t
10、he second edition of UL 60730-2-12, the requirements for the products covered by this Standard were included in UL 60730-2-12A. First Edition February, 2002 Second Edition June, 2014 Third Edition May 11, 2017 This ANSI/UL Standard for Safety consists of the Third Edition. The most recent designatio
11、n of ANSI/UL 60730-2-12 as an American National Standard (ANSI) occurred on May 11, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page or Preface. The National Difference Page and IEC Foreword are also excluded from the ANSI approval of IEC-based standa
12、rds. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed
13、 nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 60730-2-12-2017UL COPYRIGHTED MATERIAL
14、NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 11, 2017 UL 60730-2-12 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface (UL) 6 NATIONAL DIFFERENCES . 7 FOREWORD 8 1
15、 Scope and normative references .11 1.1 Scope 11 2 Terms and denitions 12 2.2 Denitions of types of control according to purpose 12 2.3 Denitions relating to the function of controls .13 3 General requirements 13 4 General notes on tests .13 4.1 Conditions of test 13 5 Rating 13 6 Classication 13 6.
16、3 According to their purpose 14 6.4 According to features of automatic action .14 7 Information 14 7.2 Methods of providing information 14 8 Protection against electric shock .15 9 Provision for protective earthing .15 10 Terminals and terminations 15 11 Constructional requirements 15 12 Moisture an
17、d dust resistance .15 13 Electric strength and insulation resistance .15 14 Heating 15 15 Manufacturing deviation and drift .15 16 Environmental stress 16 17 Endurance .16 17.3 Thermal conditions for the tests 16 17.4 Manual and mechanical conditions for the tests 17 17.7 Overvoltage (or, in Canada
18、and the USA, overload) test of automatic action at accelerated rate 17 17.8 Test of automatic action at accelerated rate .18 17.9 Test of automatic action at slow rate 18 17.10 Overvoltage (or overload test in Canada USA and 17.10 all countries that use the overload test) of manual action at acceler
19、ated speed 18 17.11 Test of manual action at slow speed .18 17.12 Test of manual action at high speed .19 17.13 Test of manual action at accelerated speed 19 18 Mechanical strength .19 18.101 Locking tests 19 19 Threaded parts and connections 20 20 Creepage distances, clearances and distances throug
20、h solid insulation .20 21 Resistance to heat, re and tracking 20 22 Resistance to corrosion 20 23 Electromagnetic compatibility (EMC) requirements Emission .20 24 Components .20 25 Normal operation .20 MAY 11, 2017 UL 60730-2-12 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DIS
21、TRIBUTION WITHOUT PERMISSION FROM UL 26 Electromagnetic compatibility (EMC) requirements Immunity .20 27 Abnormal operation .20 27.5 Not applicable. .21 27.101 Test with disconnected phase on three phase electrically operated door locks with motors 21 27.102 Running overload test 21 28 Guidance on t
22、he use of electronic disconnection .22 Annexes Annex H (normative) Requirements for electronic controls H.2 Terms and denitions 24 H.6 Classication 24 H.6.18 According to classes of control functions 24 H.7 Information 24 H.11 Constructional requirements 25 H.11.12 Controls using software 25 H.26 El
23、ectromagnetic compatibility (EMC) requirements Immunity .25 H.26.6 Test of inuence of voltage unbalance 26 H.26.7 Test of the inuence of d.c. in a.c. networks .26 H.26.8 Surge immunity test 26 H.26.9 Electrical fast transient/burst test .26 H.26.10 Ring wave immunity test .27 H.26.12 Radio-frequency
24、 electromagnetic eld immunity .27 H.26.13 Test of inuence of supply frequency variations .28 H.26.14 Power frequency magnetic eld immunity test 28 H.26.15 Evaluation of compliance .28 H.27 Abnormal operation .28 MAY 11, 2017 UL 60730-2-12 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCT
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL607302122017ULSTANDARDFORSAFETYAUTOMATICELECTRICALCONTROLSCPART212PARTICULARREQUIREMENTSFORELECTRICALLYOPERATEDDOORLOCKSTHIRDEDITIONPDF

链接地址:http://www.mydoc123.com/p-439352.html