《ANSI ASA S3.55 PART 1-2014 American National Standard Electroacoustics C Simulators of Human Head and Ear C Part 1 Ear Simulator for the Measurement of Supra-aural and Circumaural .pdf》由会员分享,可在线阅读,更多相关《ANSI ASA S3.55 PART 1-2014 American National Standard Electroacoustics C Simulators of Human Head and Ear C Part 1 Ear Simulator for the Measurement of Supra-aural and Circumaural .pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/ASA S3.55-2014/Part 1 / IEC 60318-1:2009 AMERICAN NATIONAL STANDARD Electroacoustics Simulators of Human Head and Ear Part 1: Ear Simulator for the Measurement of Supra-Aural and Circumaural Earphones (a nationally adopted international standard) Secretariat: Acoustical Society of America Appro
2、ved on January 21, 2014 by: American National Standards Institute, Inc. Abstract ANSI/ASA S3.55-2014 / IEC 60318-1:2009 specifies an ear simulator for the measurement of supra-aural and circumaural earphones (used for example in audiometry and telephonometry) applied to the ear without acoustical le
3、akage, in the frequency range from 20 Hz to 10 kHz. The same device can be used as an acoustic coupler at additional frequencies up to 16 kHz. AMERICAN NATIONAL STANDARDS ON BIOACOUSTICS The Acoustical Society of America (ASA) provides the Secretariat for Accredited Standards Committees S1 on Acoust
4、ics, S2 on Mechanical Vibration and Shock, S3 on Bioacoustics, S3/SC 1 on Animal Bioacoustics, and S12 on Noise. These committees have wide representation from the technical community (manufacturers, consumers, trade associations, organizations with a general interest, and government representatives
5、). The standards are published by the Acoustical Society of America as American National Standards after approval by their respective Standards Committees and the American National Standards Institute (ANSI). These standards are developed and published as a public service to provide standards useful
6、 to the public, industry, and consumers, and to Federal, State, and local governments. Each of the Accredited Standards Committees (operating in accordance with procedures approved by ANSI) is responsible for developing, voting upon, and maintaining or revising its own Standards. The ASA Standards S
7、ecretariat administers Committee organization and activity and provides liaison between the Accredited Standards Committees and ANSI. After the Standards have been produced and adopted by the Accredited Standards Committees, and approved as American National Standards by ANSI, the ASA Standards Secr
8、etariat arranges for their publication and distribution. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by d
9、irectly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered and that a concerted effort be made towards their resolution. The use of an American National Standar
10、d is completely voluntary. Their existence does not in any respect preclude anyone, whether he or she has approved the Standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the Standards. NOTICE: This American National Standard may
11、 be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this Standard. Acoustical Society of America ASA Secretariat 35 Pinelawn Road, Suite 114E Melville, New York 11747-3177 Telepho
12、ne: 1 (631) 390-0215 Fax: 1 (631) 390-0217 E-mail: asastdsaip.org 2014 by Acoustical Society of America. This standard may not be reproduced in whole or in part in any form for sale, promotion, or any commercial purpose, or any purpose not falling within the provisions of the U.S. Copyright Act of 1
13、976, without prior written permission of the publisher. For permission, address a request to the Standards Secretariat of the Acoustical Society of America. These materials are subject to copyright claims of IEC and ASA. No part of this publication may be reproduced in any form, including an electro
14、nic retrieval system, without the prior written permission of the Acoustical Society of America (ASA). All requests pertaining to this standard should be submitted to the Acoustical Society of America. 2014 Acoustical Society of America All rights reserved i Contents 1 Scope . 1 2 Normative referenc
15、es 1 3 Terms and definitions 1 4 Construction . 2 4.1 General . 2 4.2 Tolerances 5 4.3 Static pressure equalization . 5 4.4 Calibrated pressure-type microphone 5 4.5 Material . 6 4.6 Measurement plane 6 4.7 Acoustic transfer impedance 6 5 Coupling of earphone to ear simulator 6 5.1 Supra-aural earph
16、ones . 6 5.2 Circumaural earphones 8 6 Calibration 8 6.1 Reference environmental conditions 8 6.2 Method of calibration 8 7 Maximum permitted expanded uncertainty of measurements . 9 Annex A (informative) Lumped parameter electrical network analogue of the ear simulator . 10 Annex B (informative) Ex
17、ample of one specific design of ear simulator 12 B.1 General . 12 B.2 Adapter for use with circumaural earphones 13 B.3 Configuration using the adapter . 14 Annex C (informative) Measurement method for the determination of the acoustical transfer impedance of the ear simulator . 16 C.1 Measurement m
18、ethod 16 C.2 Measurement uncertainty . 19 Tables Table 1 Specification for the acoustic transfer impedance level 7 Table 2 Values of Umax for basic measurements . 9 2014 Acoustical Society of America All rights reserved ii Table C.1 Typical components of measurement uncertainty in the measurement of
19、 acoustic transfer impedance . 19 Figures Figure 1 Schematic cross-section of the ear simulator configured for supra-aural earphones. 3 Figure 2 Schematic cross-section of the ear simulator configured for circumaural earphones 4 Figure A.1 Analogue electrical network 10 Figure A.2 Level of impedance
20、 modulus of the electrical analogue network . 11 Figure A.3 Phase of the impedance of the electrical analogue network 11 Figure B.1 Example of one specific design of ear simulator 12 Figure B.2 Adapter for use with circumaural earphones 13 Figure B.3 Conical ring . 14 Figure B.4 Configuration when u
21、sing the adapter and the conical ring . 15 Figure C.1 Key elements of measurement system 17 Figure C.2 Transmitter microphone adapter to couple a transmitter microphone to the ear simulator . 18 2014 Acoustical Society of America All rights reserved iii Foreword This Foreword is for information only
22、, and is not a part of the American National Standard ANSI/ASA S3.55-2014/Part 1 / IEC 60318-1:2009 American National Standard Electroacoustics Simulators of Human Head and Ear Part 1: Ear Simulator for the Measurement of Supra-aural and Circumaural Earphones. As such, this Foreword may contain mate
23、rial that has not been subjected to public review or a consensus process. In addition, it does not contain requirements necessary for conformance to the standard. This standard comprises a part of a group of definitions, standards, and specifications for use in bioacoustics. It was developed and app
24、roved by Accredited Standards Committee S3, Bioacoustics, under its approved operating procedures. Those procedures have been accredited by the American National Standards Institute (ANSI). The Scope of Accredited Standards Committee S3 is as follows: Standards, specifications, methods of measuremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASAS355PART12014AMERICANNATIONALSTANDARDELECTROACOUSTICSCSIMULATORSOFHUMANHEADANDEARCPART1EARSIMULATORFORTHEMEASUREMENTOFSUPRAAURALANDCIRCUMAURALPDF

链接地址:http://www.mydoc123.com/p-431218.html