ANSI American Society of Sanitary Engineering 1063-2016 Performance Requirements for Air Valve and Vent Inflow Preventer.pdf
《ANSI American Society of Sanitary Engineering 1063-2016 Performance Requirements for Air Valve and Vent Inflow Preventer.pdf》由会员分享,可在线阅读,更多相关《ANSI American Society of Sanitary Engineering 1063-2016 Performance Requirements for Air Valve and Vent Inflow Preventer.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Performance Requirements for Air Valve and Vent Inflow Preventer ASSE InternationalASSE Standard #1063-2016ASSE Board Approved: September 2016ANSI Approved: August 2016 ICS Code: 23 040 99An American National StandardAir Valve and Vent Inflow Preventer iASSE Standard #1063-2016ASSE InternationalMoke
2、na, IllinoisCopyright 2016, 2008Neither this standard, nor any portion thereof, may be reproduced without the written consent of the ASSE International.No product may be said to be listed by ASSE unless the manufacturer has applied to ASSE International, has had its product tested according to the a
3、pplicable standards, and when the product has passed the test, displays the ASSE Seal on the product.Instructions for receiving the authorization to display the seal are available from the ASSE International office. Organizations wishing to adopt or list any ASSE standard should print the ASSE stand
4、ard number on the cover page first in equal or larger type to that of the adopting or listing organization. General Informationii Air Valve and Vent Inflow Preventer ASSE Standard #1063-2016Air Valve and Vent Inflow Preventer iiiASSE Standard #1063-2016This foreword shall not be considered a part of
5、 the standard; however, it is offered to provide background information.ASSE International standards are developed in the interest of consumer safety.Water distribution systems are equipped with air valves and air vents at multiple locations to release and admit air into pipelines and reservoirs to
6、allow filling and draining, control surges, and maintain flow efficiency. If the valve or reservoir outlets become flooded or are the target of malicious tampering, the air entry point may be compromised and allow the entry of floodwater, or the intentional introduction of a contaminant to the water
7、 system. The air valve and vent inflow preventer is directly connected to air valve outlets and reservoir vent pipes. This assembly is normally open to allow unrestricted airflow in and out of pipelines and reservoirs during normal conditions. When a flood occurs, a float-operated closure member aut
8、omatically closes to prevent the entry of contaminated fluids. A redundant, float-operated closure member automatically closes if the first one fails. The assembly is mounted in, or near, air valve vaults or reservoir vents. Air valves are sometimes required to relieve a vacuum in a pipeline system
9、to protect the appurtenant equipment. During flooded conditions, the inflow preventer will be closed and will not provide vacuum protection. Similarly, a submerged air valve without an inflow preventer will also not provide vacuum protection. If vacuum protection is required to protect the associate
10、d pipe from collapse, a pipe riser with a screened outlet that extends above the maximum expected flood level should be considered.Recognition is made of the time volunteered by members of this working group and of the support of manufacturers, who also participated in meetings for this standard.Thi
11、s standard does not imply ASSE Internationals endorsement of a product that conforms to these requirements. Compliance with this standard does not imply acceptance by any code body.This standard was promulgated in accordance with procedures developed by the American National Standards Institute (ANS
12、I).Forewordiv Air Valve and Vent Inflow Preventer ASSE Standard #1063-2016Edward J. Lyczko, ChairpersonCleveland Clinic Retiree Cleveland, OHWilliam Briggs Jr.MGJ AssociatesNew York, NYTerry BurgerNSF InternationalYpsilanti, MIWilliam ChapinProfessional Code Consulting, LLCCullman, ALMark FishZurn I
13、ndustries, LLCCary, NCRon GeorgePlumb-Tech Design & Consulting Services, LLCNewport, MIDaniel GleibermanSloan Los Angeles, CAJohn F. Higdon P.E.Apollo Valves / Conbraco Industries, Inc.Matthews, NCGary HowardIllinois Plumbing Inspector RetireeLaGrange, IL2016 Product Standards CommitteeConrad Jahrli
14、ng (non-voting)ASSE InternationalChicago, ILChuck LottPrecision Plumbing ProductsPortland, ORPeter MarzecUnited Association of Plumbers and PipefittersPearl River, NYThomas PitcherelloState of New JerseyBordentown, NJDaniel RademacherPlumbing Code and Design ConsultingButte, MTShabbir Rawalpindiwala
15、Kohler CompanyKohler, WIBilly SmithAmerican Society of Plumbing Engineers (ASPE)Montgomery, ALTsan-Liang Su, PhDStevens Institute of TechnologyHoboken, NJAir Valve and Vent Inflow Preventer vASSE Standard #1063-2016John Ballun, ChairpersonVal-Matic Valve and Mfg. Corp.Elmhurst, ILDawn FlancherAmeric
16、an Water Works Association (AWWA)Denver, CO1063 Working Group Conrad Jahrling (non-voting)ASSE InternationalChicago, ILKenneth J. KerrKerr MarketingBrunswick, OHvi Air Valve and Vent Inflow Preventer ASSE Standard #1063-2016Table of ContentsSection I . 11.0 General . 11.1 Application 11.2 Scope . 11
17、.3 Limitation on Design . 1Table 1 2Table 2 21.4 Reference Standards . 3Section II . 42.0 Test Specimens 42.1 Samples Submitted 42.2 Samples Tested 42.3 Drawings 42.4 Rejection 4Section III 53.0 Performance Requirements and Compliance Testing 53.1 Hydrostatic Testing of Complete Assembly 5Figure 1 5
18、3.2 Water Tightness Test of Float-Operated Checks 6Figure 2 63.3 Allowable Pressure Loss at Rated Air Flow . 6Figure 3 73.4 Reverse Flow Test 7Figure 4 8Section IV 94.0 Detailed Requirements . 94.1 Materials . 94.2 Documentation . 94.3 Markings . 10Section V 115.0 Definitions 11Appendix 12A1.0 Recom
19、mended Installation Guidelines . 12A1.1 General . 12A1.2 Orientation 12A1.1 Clearances . 12Figure 5 13Air Valve and Vent Inflow Preventer 1ASSE Standard #1063-2016Performance Requirements for Air Valve and Vent Inflow PreventerSection I1.0 General 1.1 ApplicationThe purpose of air valve and vent inf
20、low preventer assemblies (herein after referred to as the “assembly”) is to allow the release and admission of high volumes of air through air valves and air vents in potable water distribution systems, but prevent the entry of contaminated water when the air valve outlet becomes submerged from floo
21、ding or is the target of malicious tampering. 1.2 Scope1.2.1 DescriptionThis assembly shall consist of a primary and secondary chamber. Each chamber shall contain an independent float-operated closure member. The primary chamber is the lower chamber. The secondary or upper chamber is redundant and w
22、ill close in the event that the primary chamber fails to close. Other configurations achieving the performance requirements of this standard are acceptable.1.2.2 Size Range and ConnectionsSizes 1 to 4 NPS (25 to 100 mm) shall be furnished with an NPTF threaded connection. Sizes 6 to 16 NPS (150 to 4
23、00 mm) shall be furnished with a flanged connection.1.2.3 Pressure RangeThe assembly shall be designed and constructed for an operating pressure range of 9.7 psia (66.9 kPaabsolute) to 25.0 psi (172.4 kPa).1.2.4 Temperature RangeThe assembly shall function at temperatures from 32.0 F to 150.0 F (0 C
24、 to 65.6 C).1.3 Limitations on Design1.3.1 Flow DesignFlow ways through the entire assembly passage-way shall be as follows:a) The least cross-sectional area of the air flow ways, including the seat areas, shall not be less than the inside cross-sectional area of the same NPS.b) The manufacturer sha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAMERICANSOCIETYOFSANITARYENGINEERING10632016PERFORMANCEREQUIREMENTSFORAIRVALVEANDVENTINFLOWPREVENTERPDF

链接地址:http://www.mydoc123.com/p-430871.html