1、 2011 Standard for Performance Rating of Air Terminals Approved by ANSI on 27 October 2011 ANSI/AHRI Standard 880 (I-P) Price $12.00 (M) $25.00 (NM) Printed in U.S.A. Copyright 2011, by Air-Conditioning, Heating and Refrigeration Institute Registered United States Patent and Trademark Office IMPORTA
2、NT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, as
3、sembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/ guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI do
4、es not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. AHRI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program The certification program includes all Air Terminals as defined in Section 3. Exclusion: This certific
5、ation program does not apply to the rating and testing of retrofit units. Certified Ratings The following certification program ratings are verified by test at the standard rating conditions (Section 7.2): Primary Airflow, cfm Induced or Fan Airflow, cfm Electrical Power Input, watts Minimum Operati
6、ng Pressure, in H2O Radiated Sound Power Level, dB (125 to 4000 Hz octave band) Discharge Sound Power Level, dB (125 to 4000 Hz octave band) USE OF THE SOUND RATINGS Sound power level data generated by use of this standard with air terminals are directly applicable to AHRI Standard 885, a procedure
7、for using published sound ratings in the estimating of sound levels in occupied spaces. Note: For SI ratings, see ANSI/AHRI Standard 881 (SI)-2011. This Standard supersedes AHRI Standard 880-2008 and differs in the following way. Clarification that sound measurements shall be performed in one-third
8、octave band levels and all corrections for background noise and duct end reflection, if applicable, shall be applied to the one-third octave band test data. A Duct End Correction shall be calculated using the actual test duct dimensions, and shall be added to the discharge sound ratings. Foreword Un
9、its tested and rated in accordance with ANSI/AHRI Standard 880 (I-P) are required to be tested in a reverberation room that meets the broadband requirements of AHRI Standard 220. Units certified in accordance with the ANSI/AHRI Standard 880 (I-P) Certification Program are required to be verified by
10、a test in a reverberation room that meets both the broadband and pure tone qualification requirements of AHRI Standard 220. TABLE OF CONTENTS PAGE Section 1. Purpose .1 Section 2. Scope 1 Section 3. Definitions1 Section 4. Symbols5 Section 5. Classifications 6 Section 6. Test Requirements .6 Section
11、 7. Rating Requirements 8 Section 8. Minimum Data Requirements for Published Ratings 11 Section 9. Marking 12 Section 10. Voluntary Conformance 12 TABLES Table 1. Octave Band Center Frequencies .3 Table 2. Symbols5 Table 3. Expression of Airflow Rates 8 Table 4. Minimum Significant Sound Power Level
12、s 8 Table 5. Recommended Inlet Airflow10 Table 6. Discharge/Radiated Sound Power Level Standard Rating Conditions 10 Table 7. Sound Power Level Rating Tolerances 11 FIGURES Figure 1. Air Terminal and Air Outlet Configuration 4 Figure 2. Acoustically Isolated Duct .7 Figure 3. Acoustically Isolated (
13、Lagged) Duct .7 APPENDICES Appendix A. References Normative .13 Appendix B. References Informative .13 ANSI/AHRI STANDARD 880 (I-P)-2011 1 PERFORMANCE RATING OF AIR TERMINALS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish for Air Terminals: definitions; classifications;
14、 test requirements; rating requirements; minimum data requirements for Published Ratings; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2 Rev
15、iew and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to air control devices used in air distribution systems. These devices provide control of air volume with or without temperature control by one or more of the
16、 following means and may or may not include a fan: 2.1.1 Fixed or adjustable directional vanes (i.e. Bypass Air Terminal) 2.1.2 Pressure dependent volume dampers or valves (including air induction nozzles and Dampers) 2.1.3 Pressure compensated volume dampers or valves (including air induction nozzl
17、es and Dampers) 2.1.4 Integral heat exchange 2.1.5 On/off fan control 2.1.6 Variable speed fan control 2.1.7 Integral Diffuser Air Terminals 2.2 Exclusions. This standard does not apply to registers, diffusers and grilles or to products specifically covered by AHRI Standard 410 or AHRI Standard 440.
18、 Section 3. Definitions All terms in this document follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning, and Refrigeration unless otherwise defined in this section. 3.1 Acoustic Test Duct. Duct used to convey the sound of the
19、 unit configuration under test to the reverberation room during a ducted discharge test. A duct end correction (E1) shall be added to the sound data measured in the reverberation room to account for the presence of an open-ended duct termination. 3.2 Acoustically Isolated. The specimen under test sh
20、all have a sound pressure level at least 10 dB higher than any extraneous sound sources, such as sound generated from the air supply or duct walls, to insure that the test specimen is the sole contributor to the sound level being measured. 3.3 Air. 3.3.1 Primary Air. Air supplied to an air terminal
21、inlet under positive static gage pressure, normally from an air handling unit. 3.3.2 Secondary Air. Air drawn into an Air Terminal by means of induction and discharged through the air terminal outlet. 3.3.3 Standard Air. Air weighing 0.075 lb/ft3which approximates dry air at 70F and at a barometric
22、pressure of 29.92 in. Hg. ANSI/AHRI STANDARD 880 (I-P)-2011 2 3.4 Airflow. Unit volume displacement of standard air per unit time, cfm. The various types of airflow are defined as follows: 3.4.1 Induced Airflow. The flow of secondary air into an Air Terminal resulting from a pressure differential wi
23、thin the terminal.3.4.2 Rated Airflow. The flow of air through an Air Terminal at which test or performance data is generated. 3.4.3 Standard Airflow. Airflow corrected for standard air density. Qs= Qa(a/s) 1 3.5 Air Terminal . A device that modulates the volume of air delivered to or removed from a
24、 defined space in response to an external demand (Figure 1). The various types of Air Terminals are: 3.5.1 Bypass Air Terminal. Air Terminal, typically having more than one outlet, that uses a method of volume modulation whereby airflow is varied by distributing that volume required to meet the spac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAHRI880IP2011PERFORMANCERATINGOFAIRTERMINALSPDF

链接地址:http://www.mydoc123.com/p-430626.html