1、AMSC N/A FSC 6680 INCH-POUND MIL-PRF-25439C 24 September 2013 SUPERSEDING MIL-PRF-25439B 1 July 1997 PERFORMANCE SPECIFICATION TRANSMITTER RATE OF FLOW, IN-FLIGHT REFUELING, 0-10,000 PPM, TYPE MB-3 Comments, suggestions, or questions on this document should be addressed to Oklahoma City Air Logistic
2、s Center/ENSDAA, 3001 Staff Drive, Suite 1AB81A, Tinker AFB, OK 73145 or emailed to af71tinker.af.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo repr
3、oduction or networking permitted without license from IHS-,-,-MIL-PRF-25439C 2 This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of in-flight refueling rate of flow and fuel transmitter, designa
4、ted Type MB-3. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While e
5、very effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of the documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications and stand
6、ards and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-5624 - Turbi
7、ne Fuel, Aviation, Grades JP-4 and JP-5 MIL-PRF-38120 - Indicator, Rate of Flow and Transfer EFU-20/A DEPARTMENT OF DEFENSE STANDARDS MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment (Copies of these documents are available online
8、 at http:/quicksearch.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues o
9、f these documents are those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM-B117 - Salt Spray (Fog) Testing Apparatus, Operating ASTM-D910 - Gasolines, Aviation Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25439C 3 (ASTM doc
10、uments may be obtained online at http:/www.astm.org/ or from American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) SAE INTERNATIONAL SAE-ARP8615 - Fuel System Components: General Specification for SAE-AS31061 - Connector, Plug, Electric, Straight, Sold
11、er Contacts AN Type SAE-AS31081 - Connectors, Plug, Electric, Solder Contact, 90 Degree, AN Type (SAE documents may be obtained online at http:/www.sae.org/ or from SAE International Headquarters, 400 Commonwealth Drive, Warrendale, PA 15096-0001 USA.) 2.4 Order of precedence. Unless otherwise noted
12、 herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIR
13、EMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.1 and 4.3. 3.2 Function. The transmitter shall be designed to provide an electrical output signal for a fuel flow range of 0 to 10,000 pounds per minute (ppm). The signal
14、shall be suitable for remote indication and for use in operating an EFU-20/A indicator conforming to MIL-PRF-38120. 3.3 Design and Construction. 3.3.1 Output signal. The electrical signal shall be single phase, 400 Hertz, AC voltage. The magnitude of the voltage shall be 1 V per 1,00 ppm fuel flow.
15、The electrical output signal shall have a carrier frequency identical to the input power frequency. The output voltage signal shall be at a leading phase angle of 15 with respect to the input voltage. 3.3.2 Excess flow. The transmitter shall not be damaged by fuel flow rates in excess of the rated v
16、alue provided the pressure rating of the transmitter is not exceeded. 3.3.3 Fuel variations. The transmitter shall be designed to operate satisfactorily when using fuel having any of the variations in standard characteristics specified in MIL-DTL-5624 and ASTM-D910. 3.3.4 Operating pressure. The tra
17、nsmitter shall be designed for a normal operating pressure of 120 psi, a proof pressure of 240 psi, and a burst pressure of 480 psi. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25439C 4 3.3.5 Electrical power. The electrical power for the
18、 output signal circuit shall be 115 V AC, 400 Hertz. There shall be no voltage phase angle difference between this power and the power to the rest of the system. The wave form of the supply voltage may be nonsinusoidal with a crest factor of 1.414 10% and with harmonics having respective amplitudes
19、that are less than 5% of the fundamental. 3.3.6 External wiring. The in-flight refueling system interconnecting wiring diagram shall conform to Figure 1. 3.3.7 Density correction. The transmitter shall measure the fuel flow rate on a gravimetric basis without a separate and distinct density correcti
20、ng means. 3.3.8 Fuel line connections. The transmitter shall be designed for mounting by means of the fuel line connections or by straps. The fuel line connections shall be as specified by the procuring activity and shall be furnished with a suitable plugs or caps to prevent contamination by foreign
21、 material during storage and shipment. The fuel system tubing adjacent to the transmitter shall be in accordance with requirements of the procuring activity. 3.3.9 Damping. The transmitter shall be suitably damped. 3.3.10 Dimensions. The dimensions of the transmitter shall conform to Figure 2. 3.3.1
22、1 Flow direction. The direction of fuel flow through the transmitter shall be permanently and legibly marked on each side by an arrow as shown on Figure 2. 3.3.12 Weight. The weight of the transmitter shall not exceed 18.0 pounds. Provided by IHSNot for ResaleNo reproduction or networking permitted
23、without license from IHS-,-,-MIL-PRF-25439C 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-25439C 6 Notes: 1. Dimensions are in inches. FIGURE 2. Transmitter. Provided by IHSNot for ResaleNo reproduction or networking permitted without lic
24、ense from IHS-,-,-MIL-PRF-25439C 7 3.4 Performance. The transmitter shall be capable of meeting the requirements specified herein when subjected to the following conditions: a. Temperature - Temperatures within the range of -54 to +71C. b. Humidity - Relative humidity up to 100%. c. Salt spray - Exp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF25439C2013TRANSMITTERRATEOFFLOWINFLIGHTREFUELING010000PPMTYPEMB3PDF

链接地址:http://www.mydoc123.com/p-428174.html