BS PD CLC TS 50131-2-11-2017 Alarm systems Intrusion and hold-up systems Intrusion detectors ALDDR《警报系统 入侵和滞留报警系统 入侵探测器 ALDDR》.pdf
《BS PD CLC TS 50131-2-11-2017 Alarm systems Intrusion and hold-up systems Intrusion detectors ALDDR《警报系统 入侵和滞留报警系统 入侵探测器 ALDDR》.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TS 50131-2-11-2017 Alarm systems Intrusion and hold-up systems Intrusion detectors ALDDR《警报系统 入侵和滞留报警系统 入侵探测器 ALDDR》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、Alarm systems Intrusion and hold-up systems Part 2-11: Intrusion detectors ALDDR PD CLC/TS 50131-2-11:2017 BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National foreword This Published Document is the UK implementation of CLC/TS 50131-2-11:2017. The UK participat
2、ion in its preparation was entrusted by Technical Committee GW/1, Electronic security systems, to Subcommittee GW/1/1, Alarm components. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary p
3、rovisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017. Published by BSI Standards Limited 2017 ISBN 978 0 580 86348 6 ICS 13.320 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was
4、published under the authority of the Standards Policy and Strategy Committee on 28 February 2017. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD CLC/TS 50131-2-11:2017 TECHNICAL SPECIFICATION SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CLC/TS 50131-2-11 J
5、anuary 2017 ICS 13.320 English Version Alarm systems - Intrusion and hold-up systems - Part 2-11: Intrusion detectors - ALDDR Systmes dalarme - Systmes dalarme contre lintrusion et les hold-up - Partie 2-11: Dtecteurs faisceaux laser - ALDDR Alarmanlagen - Einbruch- und berfallmeldeanlagen - Teil 2-
6、11: Einbruchmelder - ALDDR This Technical Specification was approved by CENELEC on 2016-11-28. CENELEC members are required to announce the existence of this TS in the same way as for an EN and to make the TS available promptly at national level in an appropriate form. It is permissible to keep conf
7、licting national standards in force. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, L
8、ithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechni
9、sche Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TS 50131-2-11:2017 E PD CLC/TS 50131-2-11:2017CLC/TS 50131-2-11:2017 (E) 2 Contents Page European fo
10、reword 4 Introduction 5 1 Scope 6 2 Normative references 6 3 Terms, definitions and abbreviations 6 3.1 Terms and definitions 6 3.2 Abbreviations 7 4 Functional requirements . 7 4.1 Event processing 7 4.2 Detection . 9 4.3 Operational requirements 10 4.4 Immunity to incorrect operation . 10 4.5 Tamp
11、er security 11 4.6 Environmental classification and conditions 12 5 Marking, identification and documentation 13 5.1 Marking and/or identification 13 5.2 Documentation 13 6 Testing 13 6.1 General test conditions 14 6.2 Basic detection test 14 6.3 Performance testing . 15 6.4 ALDDR switch-on behaviou
12、r . 17 6.5 Self-tests 18 6.6 Immunity to incorrect operation . 18 6.7 Tamper security 19 6.8 Electrical tests 21 6.9 Environmental classification and conditions 22 6.10 Marking, identification and documentation . 23 Annex A (informative) Free fall of mechanical cylinder object for interruption time
13、testing . 24 Annex B (informative) Immunity to visible and near infrared radiation . 26 Annex C (normative) Dimensions and requirements of the standardized interference test magnet 27 Annex D (informative) General testing matrix . 31 Annex E (informative) Example list of small tools 33 PD CLC/TS 501
14、31-2-11:2017CLC/TS 50131-2-11:2017 (E) 3 Annex F (informative) Equipment for walk test velocity control . 34 Annex G (informative) Walk test diagrams 35 Annex H (informative) Definition of the diffuse reflection material 39 Annex I (normative) List of masking materials . 40 Annex J (informative) Def
15、inition of object against false detection . 41 PD CLC/TS 50131-2-11:2017CLC/TS 50131-2-11:2017 (E) 4 European Foreword This document (CLC/TS 50131-2-11:2017) has been prepared by the CLC/TC 79 “Alarm systems”. Attention is drawn to the possibility that some of the elements of this document may be th
16、e subject of patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights. PD CLC/TS 50131-2-11:2017CLC/TS 50131-2-11:2017 (E) 5 Introduction This Technical Specification deals with Active Laser Detector Responsive to Diffuse Reflection (to be referred to as ALD
17、DR) installed inside buildings, used as part of intrusion alarm systems. It includes four security grades and four environmental classes. The purpose of an ALDDR is to detect an intruder inside a predefined area and to provide the necessary range of signals or messages to be used by the rest of the
18、intrusion alarm system. The number and scope of these signals or messages will be more comprehensive for systems that are specified at the higher grades. This Technical Specification is only concerned with the requirements and tests for the ALDDR. Other types of detectors are covered by other docume
19、nts identified as in EN 50131-2 series. PD CLC/TS 50131-2-11:2017CLC/TS 50131-2-11:2017 (E) 6 1 Scope This Technical Specification is for ALDDR inside buildings and provides four security grades 1 to 4 (see EN 50131-1), specific or non-specific wire or wire-free ALDDR, and uses environmental classes
20、 I to IV (see EN 50130-5). An ALDDR fulfils all the requirements of the specified grade. The ALDDR detects an intruder inside a predefined area. This standard covers ALDDR using both pulsed and continuous wave laser operation technologies according to LIDAR principle (Light Detection And Ranging). O
21、ther technologies i.e. doppler based laser operation or use of additional retro-reflective objects or video based technologies are not covered by this standard. Functions additional to the mandatory functions specified in this standard may be included in the ALDDR, providing they do not adversely in
22、fluence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections. This Technical Specification does not deal with requirements for compliance with regulatory directives, such as EMC-directive, low-voltage directive, etc., except that it
23、 specifies the equipment operating conditions for EMC- susceptibility testing as required by EN 50130-4. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTS501312112017ALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSINTRUSIONDETECTORSALDDR 警报 系统 入侵 滞留 报警 探测器

链接地址:http://www.mydoc123.com/p-397607.html