《ASTM D5346-17 Standard Test Method for Determination of the Pour Point of Petroleum Oil Used in Fatliquors and Softening Compounds.pdf》由会员分享,可在线阅读,更多相关《ASTM D5346-17 Standard Test Method for Determination of the Pour Point of Petroleum Oil Used in Fatliquors and Softening Compounds.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5346 17Standard Test Method forDetermination of the Pour Point of Petroleum Oil Used inFatliquors and Softening Compounds1This standard is issued under the fixed designation D5346; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the pourpoint of petroleum oils used in the softe
3、ning and stuffing ofleather, and in the manufacture of fatliquors and other soften-ing and stuffing compounds.This test method was derived fromTest Method D97 and ALCA Method H-18.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstand
4、ard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health and environmental practices and deter-mine the applicability of regulatory limitations prior to
5、use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarrier
6、s to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D97 Test Method for Pour Point of Petroleum ProductsE1 Specification for ASTM Liquid-in-Glass ThermometersE2251 Specification for Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision Liquids2.2 Other Document:ALCA Method H
7、-18 Cloud and Pour Point33. Significance and Use3.1 This test method is intended to determine the pour pointof petroleum oils used in the softening and stuffing of leather,as well as those used in the manufacture of products for suchpurpose. The pour point of petroleum oils is measured for thepurpos
8、e of quality assurance.4. Apparatus (see Fig. 1)4.1 Test Jar, clear cylindrical glass, flat bottom, 30 to33.5-mm inside diameter, and 115 to 125-mm height. Toindicate sample height the jar should be marked with a line 546 3 mm above the inside bottom.4.2 Thermometers, having ranges shown below and c
9、on-forming to the requirements prescribed in Specifications E1 orE2251 for thermometers:Temperature Thermometer NumberThermometer Range ASTM IPHigh cloud and pour 38 to +50C 5C or S5C 1CLow cloud and pour 80 to +20C 6C 2CMelting point +32 to +127C 61C 63C4.2.1 Since separation of liquid column therm
10、ometers occa-sionally occurs and may escape detection, thermometersshould be checked immediately prior to the test and used onlyif they prove accurate within 6 1C (for example ice point).4.3 Cork, to fit the test jar, bored centrally for the testthermometer.4.4 Jacket, metal or glass, watertight, cy
11、lindrical, flatbottom, 115 mm in depth, 42 to 50 mm inside diameter. It mustbe supported firmly in a vertical position in the cooling bath of4.7 so that not more than 25 mm projects out of the coolingmedium.4.5 Disk, cork or felt, 6 mm thick to fit loosely inside thejacket.4.6 Gasket, to fit snugly
12、around the outside of the test jarand loosely inside the jacket. The gasket may be made ofrubber, leather, or other material that is elastic enough to clingto the test jar and hard enough to hold its shape. Its purpose isto prevent the test jar from touching the jacket.4.7 Bath or Baths, maintained
13、at prescribed temperatureswith a firm support to hold the jacket vertical. The requiredbath temperatures may be obtained by refrigeration if1This test method is under the jurisdiction ofASTM Committee D31 on Leatherand is the direct responsibility of Subcommittee D31.08 on Fats and Oils.Current edit
14、ion approved Sept. 1, 2017. Published October 2017. Originallyapproved in 1993. Last previous edition approved in 2009 as D5346 93 (2009).DOI: 10.1520/D5346-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
15、 ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Leather Chemists Assn., Texas Tech University, P.O.Box 45300, Lubbock, TX 79409.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-29
16、59. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical
17、Barriers to Trade (TBT) Committee.1available, otherwise by suitable freezing mixtures. Freezingmixtures commonly used for temperatures down to thoseshown are as follows:For Temperatures DownIce and water 9CCrushed ice and sodium chloride crystals 12CCrushed ice and calcium chloride crystals 27CAceto
18、ne or petroleum naphtha (see Section 5) chilledin a covered metal beaker with an ice-salt mixtureto 12C then with enough solid carbon dioxide togive the desired temperature.57CNOTE 1There are automatic pour point testers available and in usewhich may be advantageous in the saving of test time, permi
19、t the use ofsmaller samples, and have other factors which may merit their use. Ifautomatic testers are used, the user must ensure that all of the manufac-turers instructions for calibration, adjustment and operation of theinstrument are followed. It must be reported that the pour point wasdetermined
20、 by an automatic instrument. Precision of automatic pour pointtesters has not been determined. In any case of dispute, the pour point asdetermined by the manual method described herein shall be considered thereference test.5. Reagents and Materials5.1 The following solvents of technical grade are ap
21、propri-ate for low-temperature bath media.5.1.1 Acetone. (WarningExtremely flammable.)5.1.2 Alcohol, Ethanol. (WarningFlammable.)5.1.3 Alcohol, Methanol. (WarningFlammable. Vaporharmful.)5.1.4 Petroleum Naphtha. (WarningCombustible. Vaporharmful.)5.1.5 Solid Carbon Dioxide. (WarningExtremelycold 78.
22、5C.)6. Procedure6.1 Pour the oil into the test jar to the level mark. Whennecessary, heat the oil in a water bath until it is just sufficientlyfluid to pour into the test jar.NOTE 2When it is known that a sample has been heated to atemperature higher than 45C during the preceding 24 h or when thethe
23、rmal history of the sample is not known, keep the sample at roomtemperature for 24 h before testing it.6.2 Close the test jar with the cork carrying the high-pourthermometer (4.2). In the case of pour points above 36C, usea higher range thermometer such as IP 3C or ASTM 61C.Adjust the position of th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D5346-17 Standard Test Method for Determination of the Pour Point Petroleum Oil Used in Fatliquors D5346

链接地址:http://www.mydoc123.com/p-349544.html