《ASTM F2132 - 01(2008)e1 Standard Specification for Puncture Resistance of Materials Used in Containers for Discarded Medical Needles and Other Sharps (Withdrawn 2017).pdf》由会员分享,可在线阅读,更多相关《ASTM F2132 - 01(2008)e1 Standard Specification for Puncture Resistance of Materials Used in Containers for Discarded Medical Needles and Other Sharps (Withdrawn 2017).pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2132 01 (Reapproved 2008)1Standard Specification forPuncture Resistance of Materials Used in Containers forDiscarded Medical Needles and Other Sharps1This standard is issued under the fixed designation F2132; the number immediately following the designation indicates the year oforigina
2、l adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial changes were made throughout in June 2008.1. Scope1.1 The purpo
3、se of this specification is to provide a testprocedure and performance requirement for the punctureresistance of materials used in the construction of containersfor discarded medical needles and other sharps. This testspecification will establish (1) the average puncture force and(2) a minimum value
4、 of puncture force that container materi-al(s) must withstand when following the test procedure de-scribed in Section 6. This specification shall be applicable toregions of uniform material and thickness, and needle contactareas as defined in 3.1.7 and 3.1.9. Materials meeting theperformance require
5、ments of Section 4 shall be considered“puncture-resistant.” This specification does not evaluate theconstruction of, or provide pass/fail criteria for, a sharpscontainer.1.2 This specification provides a test procedure to determineif all regions of one container meet the material punctureresistance
6、requirements. It does not define the number ofadditional test containers required to achieve a statisticallyvalid sample of a manufacturing lot or process. An appropriatesampling plan shall be determined by the test requester, as thisdepends upon the manufacturing process variability, manufac-turing
7、 lot size, and other factors, such as end-user require-ments.1.3 This specification is intended to evaluate the perfor-mance of materials used in the construction or manufacture ofsharps containers under controlled laboratory conditions, andat normal room temperature (see 6.1). (WarningThis speci-fi
8、cation only characterizes material puncture resistance atnormal room temperatures. Applications of sharps containersoutside the range of 23 6 2C (such as usage in emergencyvehicles) require further material characterization by the prod-uct specifier to determine suitable use.)1.4 The values stated i
9、n inch/pound are to be regarded as thestandard. The SI values given in parentheses are for informa-tion only.1.5 The following hazard caveat pertains only to the testprocedure portion, Section 6, of this specification.1.6 This standard does not purport to address all of thesafety concerns, if any, a
10、ssociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E691 Practice for Conducting an Interlaboratory Study
11、toDetermine the Precision of a Test Method2.2 ISO Standards:ISO 7864 Sterile Hypodermic Needles for Single Use3ISO 594 Luer Fittings32.3 Other Standards:AS 4031:1992 Non-reusable Containers for the Collection ofSharp Medical Items Used in Health Care Areas4BSI 7320:1990 Specification for Sharps Cont
12、ainers5CSA Z316.6-95 Evaluation of Single Use Medical SharpsContainers for Biohazardous and Cytotoxic Waste6DHHS (NIOSH) Publication No. 97-111 Selecting,Evaluating, and Using Sharps Disposal Containers71This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materi
13、als and Devices and is the direct responsibility ofSubcommittee F04.33 on Medical/Surgical Instruments.Current edition approved Feb. 1, 2008. Published March 2008. Originallyapproved in 2001. Last previous edition approved in 2001 as F2132 01. DOI:10.1520/F2132-01R08E01.2For referenced ASTM standard
14、s, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, Ne
15、w York, NY 10036, http:/www.ansi.org.4Available from Standards Australia International Ltd., 286 Sussex St., Sydney,Australia NSW 2000.5Available from British Standards Institute (BSI), 389 Chiswick High Rd.,London W4 4AL, U.K., http:/www.bsi-.6Available from Canadian Standards Association, Andre Wi
16、saksana, 178Rexdale Blvd., Etobicoke, ON Canada M9W 1R3.7Available from Publications Dissemination, EID National Institute for Occu-pational Safety and Health, 4676 Columbus Pkwy., Cincinnati, OH 45226-1998.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428
17、-2959. United StatesNOTICE: This standard has either been superseded and replaced by a new version or withdrawn.Contact ASTM International (www.astm.org) for the latest information13. Terminology3.1 Definitions:3.1.1 containera product used for the containment ofdiscarded medical needles and other s
18、harps.3.1.2 materialthe substance(s) used in the construction ofa sharps container.3.1.3 puncture forcethe minimum force applied to therepresentative sharp object that causes its tip to penetrate (exit)the opposite side of the test specimen from the side that itentered when tested in accordance with
19、 the test procedureportion, Section 6, of this specification.3.1.4 puncture resistanta region of uniform material andthickness is defined as puncture resistant if it meets Section 4of this specification when tested in accordance with Section 6of this specification.3.1.5 test specimena sample of mate
20、rial being evaluatedfor puncture resistance that is taken from the actual container(direct method) or a representative example of the material andthickness having the same characteristics as the actual con-tainer (indirect method). Refer to Section 5.3.1.6 puncture test specimena test specimen that
21、has beenpunctured using the puncture test described in 6.3, and subse-quently evaluated using the direct or indirect methods de-scribed in 7.1 and 7.2 of this specification.3.1.7 region of uniform material and thicknesssharps-contact areas of the container, in aggregate, that are made of thesame hom
22、ogeneous, composite, or laminated material, and, asa consequence of fabrication or design or both, are expected tohave the same material and thickness as other areas of thecontainer. For example, in molded containers, the cornerscould be expected to be of different thickness than the sides andbottom
23、, resulting in different regions of uniform material andthickness. Labels, tabs, membranes, or thin films coveringopenings in the container are considered separate regions ofuniform material and thickness.3.1.8 sharpsitems used in medical treatment, diagnoses,or research that may cause puncture woun
24、ds, cuts, or tears inskin or mucous membranes, including, but not limited to:hypodermic, surgical, suture, and IV needles; Pasteur pipets,lancets, razors, scalpels, and other blades and sharp objects.3.1.9 sharps-contact areasthe material of a container thatrepresents those surfaces that enclose sha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM F2132 01 2008 e1 Standard Specification for Puncture Resistance of Materials Used in Containers Discarded Medical Needles and Other Sharps Withdrawn 2017

链接地址:http://www.mydoc123.com/p-287184.html