ASTM D2522 - 03(2008)e2 Standard Test Method for Chlorine Content of Polybutenes Used for Electrical Insulation (Withdrawn 2017).pdf
《ASTM D2522 - 03(2008)e2 Standard Test Method for Chlorine Content of Polybutenes Used for Electrical Insulation (Withdrawn 2017).pdf》由会员分享,可在线阅读,更多相关《ASTM D2522 - 03(2008)e2 Standard Test Method for Chlorine Content of Polybutenes Used for Electrical Insulation (Withdrawn 2017).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2522 03 (Reapproved 2008)2Standard Test Method forChlorine Content of Polybutenes Used for ElectricalInsulation1This standard is issued under the fixed designation D2522; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThe mercury warning was editorially added in April 2009.2NOTEIn 7.7, 20 L was changed to 2 L editorially in Aug
3、ust 2009.1. Scope1.1 This test method describes the determination of the totalchloride content of polybutenes used for electrical insulation.1.2 WarningMercury has been designated by EPA andmany state agencies as a hazardous material that can causecentral nervous system, kidney, and liver damage. Me
4、rcury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury-containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website(http:/www.epa.gov/mercury/faq.htm) for additional informa
5、-tion. Users should be aware that selling mercury or mercury-containing products, or both, in your state may be prohibited bystate law.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to est
6、ablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardsinformation, see Section 8.2. Referenced Documents2.1 ASTM Standards:2D878 Test Method for Inorganic Chlorides and Sulfates inInsulating OilsD1193 Specificatio
7、n for Reagent Water3. Summary of Test Method3.1 Organically bound chlorine is converted into sodiumchloride by reaction with sodium biphenyl solution. Thesodium chloride formed is extracted with dilute nitric acid, andthe chlorine content of the aqueous phase is determined bypotentiometric titration
8、.4. Significance and Use4.1 Chlorine is normally present in polybutenes in smallamounts, usually below 50 ppm, as organically bound chlorine.Inorganic chloride is normally not present.NOTE 1The qualitative presence or absence of inorganic chloride maybe tested by Test Method D878.5. Interferences5.1
9、 The presence of substances which form insoluble silvercompounds, such as sulfides, will give high results. Suchsubstances are not normally present in polybutenes.6. Apparatus6.1 Separatory Funnel, 250-mL.6.2 Potentiometeric Titrimeter, automatic recording, ormanual.6.3 Electrodes:6.3.1 Silver and g
10、lass electrode combination is preferred.6.3.2 A silver electrode with a mercurous sulfate referenceelectrode is an acceptable alternative.6.4 Microburet, 5-mL, with 0.01-mL divisions.7. Reagents7.1 Purity of ReagentsUse reagent grade chemicals in alltests. Unless otherwise indicated, it is intended
11、that all reagentsshall conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society, wheresuch specifications are available.3Other grades may be used,1This test method is under the jurisdiction of ASTM Committee D27 onElectrical Insulating Liquids and Gases a
12、nd is the direct responsibility of Subcom-mittee D27.06 on Chemical Test.Current edition approved May 1, 2008. Published June 2008. Originallyapproved in 1969. Last previous edition approved in 2003 as D2522 03. DOI:10.1520/D2522-03R08E02.2For referenced ASTM standards, visit the ASTM website, www.a
13、stm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications , AmericanChemical Society, Washington, DC. For suggestions o
14、n the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.Copyright ASTM International, 100 Barr
15、 Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesNOTICE: This standard has either been superseded and replaced by a new version or withdrawn.Contact ASTM International (www.astm.org) for the latest information1provided it is first ascertained that the reagent is of sufficie
16、ntlyhigh purity to permit its use without lessening the accuracy ofthe determination.7.2 Purity of Water Unless otherwise indicated, referencesto water shall be understood to mean reagent grade water asdefined by Type I conforming to Specifications D1193.7.3 Dilute Nitric Acid (2.1 M)Dilute 134 mL o
17、f concen-trated nitric acid to 1.0 L with water.7.4 Isopropyl Alcohol.7.5 Silver Nitrate, Standard Solution (0.025 N)Weighaccurately 0.4247 g of silver nitrate (AgNO3). Transfer it to a1-L volumetric flask and add water to dissolve. Add 3.0 mL ofconcentrated nitric acid (HNO3, relative density (spec
18、ificgravity) 1.42) and then add water to the 1-L mark of thevolumetric flask. Standardize this solution against a purechloride standard. Check the solution at least monthly to assurea constant reagent.7.6 Sodium Chloride, NIST Standard Reference Material919A.NOTE 2Dry the silver nitrate overnight in
19、 a desiccator before makingup the solution. Both the solid material and the solution must be protectedfrom light by storage in brown glassware in the dark.7.7 Sodium Biphenyl SolutionTransfer 300 mL of drytoluene and 58 g of metallic sodium toa2L,three-neckedflask, equipped with a heating mantle, ni
20、trogen gas inlet,mercury seal stirrer, and reflux condenser. Heat until thetoluene refluxes and the sodium melts completely. Start thestirrer, and stir until the sodium is finely dispersed. Cool to lessthan 10C in a suitable bath (not water). Remove the con-denser, and add 1250 mL of dry ethylene gl
21、ycol dimethyl ether.While stirring and passing nitrogen gas over the mixture, add390 g of biphenyl. The reaction should start immediately, asevidenced by the green color of sodium biphenyl. The tem-perature of the reaction mixture should be kept below 30C.When the reaction is complete (112 to 2 h),
22、pour the reagentinto dry 500-mL brown prescription bottles with screw capsand foil liners. The reagent is stable for several months ifrefrigerated. (If any unreacted sodium remains in the reactionflask, add 100 mL of isopropyl alcohol, and place the flask ina hood until the metal has dissolved.)4NOT
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D2522 03 2008 e2 Standard Test Method for Chlorine Content of Polybutenes Used Electrical Insulation Withdrawn 2017

链接地址:http://www.mydoc123.com/p-286813.html