ASTM C1623-17a Standard Specification for Manufactured Concrete Masonry Lintels.pdf
《ASTM C1623-17a Standard Specification for Manufactured Concrete Masonry Lintels.pdf》由会员分享,可在线阅读,更多相关《ASTM C1623-17a Standard Specification for Manufactured Concrete Masonry Lintels.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1623 17aStandard Specification forManufactured Concrete Masonry Lintels1This standard is issued under the fixed designation C1623; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、 parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers concrete masonry lintels(beams) that are solid in cross-section, are reinforced forflexure, and are made from hydraul
3、ic cement, water, andmineral aggregates with or without the inclusion of othermaterials. These lintels are suitable for both loadbearing andnonloadbearing applications.NOTE 1This specification covers only concrete masonry lintelscontaining reinforcement. Due to building code imposed limitations on t
4、hedesign of masonry lintels, all lintels must contain reinforcement. Concretemasonry lintels are not typically manufactured using shear reinforcement(stirrups or other vertical reinforcement). Therefore, this standard does notaddress issues related to such. For further guidance, refer to Building Co
5、deRequirements for Masonry Structures, TMS 402. Prestressed concretelintels are not covered by this standard.1.2 Lintels are manufactured using a no-slump concrete mixto provide a surface texture similar to that of concrete masonry.This specification applies to both machine-made and hand-tamped conc
6、rete masonry lintels intended for use in concretemasonry applications.1.3 Concrete masonry lintels covered by this specificationare made from lightweight or normal weight aggregates, orboth.1.4 This specification does not address the design or analy-sis of lintel capacity. Structural evaluations mus
7、t be performedseparately. The strength of a lintel is a function of factorsincluding, but not limited to, the characteristics of the materialsused in manufacturing (concrete materials and reinforcement),the amount and location of reinforcement, and the manufac-turing and curing procedures. For desig
8、n and analysis methods,refer to Building Code Requirements for Masonry Structures,TMS 402.1.5 This specification does not cover U-shaped lintels orthose of other cross-sections that are not 100 % solid.1.6 This specification does not cover lintels of groutedconcrete masonry lintels, or precast or ca
9、st-in-place lintels ofslump concrete.1.7 The text of this standard references notes and footnotesthat provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.8 The values stated in inch-pound units are to
10、 be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.9 This international standard was developed in accor-dance with internationally recognized principles on standard-ization establish
11、ed in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2A615/A615M Specification for Deformed and Plain Carbon-Steel Bars f
12、or Concrete ReinforcementA706/A706M Specification for Deformed and Plain Low-Alloy Steel Bars for Concrete ReinforcementA996/A996M Specification for Rail-Steel and Axle-SteelDeformed Bars for Concrete ReinforcementC33 Specification for Concrete AggregatesC140 Test Methods for Sampling and Testing Co
13、ncreteMasonry Units and Related UnitsC150 Specification for Portland CementC331 Specification for Lightweight Aggregates for ConcreteMasonry UnitsC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC979 Specificat
14、ion for Pigments for Integrally Colored Con-creteC989 Specification for Slag Cement for Use in Concrete andMortarsC1157 Performance Specification for Hydraulic CementC1232 Terminology for Masonry1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is t
15、he direct responsibility of SubcommitteeC15.03 on Concrete Masonry Units and Related Units.Current edition approved Aug. 1, 2017. Published August 2017. Originallyapproved in 2005. Last previous edition approved in 2017 as C1623 17. DOI:10.1520/C1623-17A.2For referenced ASTM standards, visit the AST
16、M website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Ha
17、rbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommenda
18、tions issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1C1240 Specification for Silica Fume Used in CementitiousMixturesC1262 Test Method for Evaluating the Freeze-Thaw Dura-bility of Dry-Cast Segmental Retaining Wall Units andRelated Concrete Units2.2 Other Standar
19、ds:3TMS 402 Building Code Requirements for Masonry Struc-turesTMS 602 Specification for Masonry Structures3. Terminology3.1 Terminology defined in Terminology C1232 shall applyfor this specification.4. Material4.1 Cementitious MaterialsMaterials shall conform to thefollowing applicable specification
20、s:4.1.1 Portland CementSpecification C150.4.1.2 Modified Portland CementPortland cement con-forming to Specification C150, modified as follows:(1) LimestoneIf calcium carbonate is added to thecement, the CaCO3content shall be not less than 85 %.(2) Limitation on Insoluble Residue1.5 %.(3) Limitation
21、 on Air Content of MortarVolume percent,22 % max.(4) Limitation on Loss on Ignition7 %.4.1.3 Blended Hydraulic CementsSpecification C5954.1.4 Hydraulic CementSpecification C1157.4.1.5 PozzolansSpecification C618.4.1.6 Ground Granulated Blast Furnace SlagSpecification C989.4.1.7 Silica FumeSpecificat
22、ion C1240.4.2 AggregatesAggregates shall conform to the followingspecifications, except that grading requirements shall notnecessarily apply:4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 Lightweight AggregatesSpecification C331.4.3 Pigments for Integrally Colored ConcreteSpecification C979.4
23、.4 Steel ReinforcementSteel reinforcement shall consistof deformed bars conforming to Specifications A615/A615M,A706/A706M,orA996/A996M.4.5 Other ConstituentsAir-entraining agents, integral wa-ter repellents, and other constituents shall be previously estab-lished as suitable for use in concrete mas
24、onry lintels and shallconform to applicable ASTM standards or shall be shown bytest or experience not to be detrimental to the durability of theconcrete masonry lintels or any material customarily used inmasonry construction.5. Physical Requirements5.1 At the time of delivery to the purchaser, the c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM C1623 17 Standard Specification for Manufactured Concrete Masonry Lintels

链接地址:http://www.mydoc123.com/p-286754.html