IEC 60728-7-3-2009 Cable networks for television signals sound signals and interactive services - Part 7-3 Hybrid fibre coax outside plant status monitoring - P.pdf
《IEC 60728-7-3-2009 Cable networks for television signals sound signals and interactive services - Part 7-3 Hybrid fibre coax outside plant status monitoring - P.pdf》由会员分享,可在线阅读,更多相关《IEC 60728-7-3-2009 Cable networks for television signals sound signals and interactive services - Part 7-3 Hybrid fibre coax outside plant status monitoring - P.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、 IEC 60728-7-3 Edition 2.0 2009-10 INTERNATIONAL STANDARD Cable networks for television signals, sound signals and interactive services Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interface bus (PSTIB) IEC 60728-7-3:2009(E) colour inside THIS PUBLICATION I
2、S COPYRIGHT PROTECTED Copyright 2009 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from eit
3、her IEC or IECs member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC
4、 Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related techn
5、ologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue
6、 enables you to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a m
7、onth all new publications released. Available on-line and also by email. Electropedia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages.
8、Also known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919
9、 02 11 Fax: +41 22 919 03 00 IEC 60728-7-3 Edition 2.0 2009-10 INTERNATIONAL STANDARD Cable networks for television signals, sound signals and interactive services Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interface bus (PSTIB) INTERNATIONAL ELECTROTECHN
10、ICAL COMMISSION W ICS 33.040; 33.160 PRICE CODE ISBN 2-8318-1065-1 Registered trademark of the International Electrotechnical Commission colour inside 2 60728-7-3 IEC:2009(E) CONTENTS FOREWORD.5 INTRODUCTION.7 1 Scope.8 2 Normative references .9 3 Terms, definitions and abbreviations 9 3.1 Terms and
11、 definitions 9 3.2 Abbreviations 10 4 Reference architecture forward and return channel specifications 10 5 Power supply to transponder interface bus specification overview 11 5.1 General .11 5.2 Interface compliance .11 5.3 Implementation compliance .11 5.4 Revision control 12 6 Power supply to tra
12、nsponder interface bus Physical layer specification .12 6.1 Interface requirements 12 6.1.1 Connector type 12 6.1.2 Communications interface .12 6.1.3 Connector signals12 6.1.4 Transponder power12 6.1.5 Line balance13 6.1.6 Cable length13 6.1.7 Data encoding .13 6.1.8 Bit rate 13 6.1.9 Duplex.13 6.1
13、.10 Method of communications 13 6.1.11 Indicators 13 6.2 Interface diagram 14 7 Alternative power supply to transponder interface bus Physical layer specification .15 7.1 Introduction to alternative15 7.2 Interface requirements 15 7.2.1 Connector type 15 7.2.2 Communications interface .15 7.2.3 Conn
14、ector signals15 7.2.4 Transponder power15 7.2.5 Line balance16 7.2.6 Cable length16 7.2.7 Data encoding .16 7.2.8 Bit rate 16 7.2.9 Duplex.16 7.2.10 Method of communication16 7.2.11 Indicators 17 7.3 Interface diagram 17 8 Power supply to transponder interface bus Data link layer specification.18 8.
15、1 DLL packet structure .18 60728-7-3 IEC:2009(E) 3 8.1.1 General .18 8.1.2 Start 18 8.1.3 Destination Address 18 8.1.4 Source Address.19 8.1.5 Identification19 8.1.6 Datagram 19 8.1.7 End .19 8.1.8 Checksum .19 8.2 DLE sequence.19 8.3 Interface timing .20 8.3.1 Message synchronization and interactio
16、n 20 8.3.2 Transmission timing requirements .21 8.4 DLL datagrams22 8.4.1 Structure .22 8.4.2 Resolution versus accuracy.23 8.4.3 DLL datagram types 23 Annex A (informative) HMS specification documents37 Bibliography38 Figure 1 Reference architecture diagram .11 Figure 2 Sample PSTIB RS-485 interfac
17、e 14 Figure 3 Sample PSTIB RS-485 interface 17 Figure 4 DLL packet structure18 Figure 5 PSTIB data and timing diagram21 Figure 6 DLL datagram structure22 Figure 7 Battery string naming conventions33 Table 1 Transponder type classifications .8 Table 2 RJ-45 Connector pin assignment.12 Table 3 Sample
18、PSTIB RS-485 interface Reference signals14 Table 4 RJ-45 Connector pin assignment.15 Table 5 Sample PSTIB RS-485 interface Reference signals17 Table 6 Generic DLL packet structure18 Table 7 Reserved destination address ranges19 Table 8 PSTIB timing specifications.21 Table 9 Generic DLL datagram stru
19、cture22 Table 10 DLL datagrams24 Table 11 Command: Get_Configuration datagram24 Table 12 Response: Get_Configuration datagram 25 Table 13 Response: Get_Configuration datagram variable binding (general)25 Table 14 Response: Get_Configuration datagram variable binding (power supply).26 Table 15 Respon
20、se: Get_Configuration datagramavariable binding (generator) .29 Table 16 Command: Get_Power_Supply_Data datagram .30 Table 17 Response: Get_Power_Supply_Data datagram .30 Table 18 Response: Get_Power_Supply_Data datagram variable binding30 4 60728-7-3 IEC:2009(E) Table 19 Command: Power_Supply_Contr
21、ol datagram.33 Table 20 Command: Get_Generator_Data datagram33 Table 21 Response: Get_Generator_Data datagram 34 Table 22 Response: Get_Generator_Data Datagram variable binding34 Table 23 Command: Generator_Control datagram .35 Table 24 Response: Invalid_Request datagram .35 Table 25 Response: Reque
22、st_Processed datagram .36 Table A.1 HMS document family 37 60728-7-3 IEC:2009(E) 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interfa
23、ce bus (PSTIB) FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote interna- tional co-operation on all questions concerning stand
24、ardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Techni- cal Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their prepara
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEC60728732009CABLENETWORKSFORTELEVISIONSIGNALSSOUNDSIGNALSANDINTERACTIVESERVICESPART73HYBRIDFIBRECOAXOUTSIDEPLANTSTATUSMONITORINGPPDF

链接地址:http://www.mydoc123.com/p-1241387.html