UOP 588-2012 Total Inorganic and Organic Chloride in Hydrocarbons.pdf
《UOP 588-2012 Total Inorganic and Organic Chloride in Hydrocarbons.pdf》由会员分享,可在线阅读,更多相关《UOP 588-2012 Total Inorganic and Organic Chloride in Hydrocarbons.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS (MSDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1965, 1986, 1988, 1994, 2012 UOP LLC.
3、All rights reserved. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9
4、555 FAX, or 610.832.9585 PHONE. Total, Inorganic, and Organic Chloride in Hydrocarbons UOP Method 588-12 Scope This potentiometric method is for determining total and inorganic chloride, and calculating organic chloride, in hydrocarbons. The method is applicable to samples with chloride concentratio
5、ns of 1 mass-ppm or higher. For lower levels of chloride use UOP Method 991 “Chloride, Fluoride, and Bromide in Liquid Organics by Combustion Ion Chromatography (CIC).” Iodide and/or bromide, if present, are calculated as chloride. Samples that are polymerized by sodium biphenyl (such as styrene) ca
6、nnot be analyzed by this method. Results for samples containing ammonia and/or amines may be biased high (see Note 1). Reference UOP Method 991, “Chloride, Fluoride, and Bromide in Liquid Organics by Combustion Ion Chromatography (CIC),” www.astm.org UOP Method 999, “Precision Statements in UOP Meth
7、ods,” www.astm.org Outline of Method To determine total chloride, the hydrocarbon sample is weighed and transferred to a separatory funnel containing toluene. Sodium biphenyl reagent is added to promote rapid conversion of the organic chloride into inorganic chloride. Excess reagent is decomposed wi
8、th alcohol and water, and the phases are separated. The chloride containing aqueous phase is acidified, concentrated, acetone is added, and the solution titrated potentiometrically. Inorganic chloride determination is identical to total chloride except that the addition of sodium biphenyl reagent is
9、 omitted. Organic chloride is then calculated as the difference between the total chloride and inorganic chloride determinations. Apparatus References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Balance, readable to 0.0001 g Balance
10、, readable to 0.01 g 2 of 9 588-12 Beaker, 250-mL, tall, without spout, borosilicate glass, Wilmad-LabGlass, Cat. No. G-9906-002 Boiling chips, Fisher Scientific, Cat. No. 09-191-12 Bottles, glass, 60-mL, Fisher Scientific, Cat. No. 02-911-787 Cylinders, graduated, Class B, 10-, 25-, 50-, and 100-mL
11、, Fisher Scientific, Cat. Nos. 08-550B, C, D, and E, respectively Desiccator, with plate, Fisher Scientific, Cat. No. 08-615B Electrode, combination silver/glass Titrode Model 6.0430.100, Metrohm USA, Cat. No. 020948507 Flask, volumetric, Class A, 500-mL, Fisher Scientific, Cat. No. 10-208K Funnel,
12、separatory, 250-mL, Fisher Scientific, Cat. No. 10-437-5C Hot plate, electric, capable of maintaining 150C, Fisher Scientific, Cat. No. 11-100-49H Oven, drying, capable of operation at 110C, Fisher Scientific, Cat. No. 13-247-725G Pipet, volumetric, Class A, 50-mL, Fisher Scientific, Cat. No. 13-650
13、-2S Pipet filler, Fisher Scientific, Cat. No. 13-681-102A Stirring bars, Teflon-coated, Fisher Scientific, Cat. No. 14-512-148 Titrator, potentiometric, recording, 2000-mV range, 1-mV resolution, with dispenser having a volume readout of 0.00 to 99.9 mL and 0.01% resolution, Titrando Model 904, Metr
14、ohm USA Tongs, beaker, Fisher Scientific, Cat. No. 02-622 Tray, for ice bath, polypropylene, Fisher Scientific, Cat. No. 13-361-10 Reagents and Materials References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Unless otherwise specif
15、ied references to water mean deionized or distilled water. Acetone, 99.9% minimum purity, Fisher Scientific, Cat. No. A18-4 Cleaning pad, synthetic, mildly abrasive, Scotch-Brite, Runco Office Supply, Cat. No. MMM-96 Congo red paper, VWR, Cat. No. 60791-006 Detergent, cleaning compound, Liqui-Nox, F
16、isher Scientific, Cat. No. 04-322-15B Desiccant, Drierite, indicating, 10- to 20-mesh, Fisher Scientific, Cat. No. 07-578-4A Gloves, nitrile, Fisher Scientific, Cat. No. 11-395-19C Ice, water Isooctane, 99.9% minimum purity, Fisher Scientific, Cat. No. O301-4 Isopropyl alcohol, 99.9% minimum purity,
17、 Fisher Scientific, Cat. No. A416-4 Nitric acid, concentrated, Certified ACS Plus, Fisher Scientific, Cat. No. A200-212 Nitric acid, approximately 5N. Add 160 mL of concentrated nitric acid slowly to approximately 200 mL of water in a 500-mL volumetric flask. Dilute to the mark with water, cap and i
18、nvert several times to mix thoroughly. 3 of 9 588-12 Pipet, disposable, LDPE, Fisher Scientific, Cat. No. 13-711-9AM Potassium chloride, 99.995% minimum purity, Alfa Aesar, Cat. No. 87626, VWR. Oven dry an aliquot before each use at 105C for 2.5 hours, and cool in a desiccator. Silver nitrate, 0.1N
19、solution, Fisher Scientific, Cat. No. SS72-4, see Silver Nitrate Standardization Silver nitrate, 0.01N standard aqueous solution. Prepare by diluting the 0.1N solution, see Silver Nitrate Standardization. Sodium biphenyl reagent, commercially obtainable under the name of “Organic Halogen Reagent” fr
20、om GFS Chemicals. The reagent is packed in 18-mL bottles (hereafter referred to as “vials”). One vial contains 13 to 15 milli-equivalents of active sodium. The reagent cannot be used after the expiration date stated on the package (see Note 2). Toluene, 99.9% minimum purity, Fisher Scientific, Cat.
21、No. T324-4 Water, deionized or distilled Wipers, Kimwipes, lint free, Fisher Scientific, Cat. No. 06-666A Procedure The analyst is expected to be familiar with general laboratory practices, the technique of titration, and the equipment being used. Dispose of used reagents, materials, and samples in
22、an environmentally safe manner according to local regulations. SilverSilver Chloride Electrode Preparation and Reconditioning Proper electrode preparation is essential to obtain reproducible and noise-free titration curves having good endpoints. An electrode should be dedicated to chloride analysis.
23、 Prepare and recondition the silver-silver chloride electrode as follows: 1. Clean the silver surface with a Scotch-Brite pad. Rinse with water and dry. 2. Weigh approximately 0.1 g of potassium chloride and place in a beaker. Using a graduated cylinder, add 20 mL of 5N nitric acid and 80 mL of wate
24、r to the beaker. Immerse the electrode; and titrate to the endpoint with 0.1N silver nitrate. 3. Remove the electrode from the solution and rinse with water. 4. Wipe the excess silver chloride from the electrode with a wiper. The electrode should be cleaned after each titration by rinsing with water
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP5882012TOTALINORGANICANDORGANICCHLORIDEINHYDROCARBONSPDF

链接地址:http://www.mydoc123.com/p-1074510.html