《UL SUBJECT 2389-2002 Outline of Investigation for Coaxial Fault Protectors for Network-Powered Broadband (Issue Number 1)《(草案) 网络供电宽带用同轴故障保护器的调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2389-2002 Outline of Investigation for Coaxial Fault Protectors for Network-Powered Broadband (Issue Number 1)《(草案) 网络供电宽带用同轴故障保护器的调查大纲 发布编号 1》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、August 1, 20021SUBJECT 2389OUTLINE OF INVESTIGATIONFORCOAXIAL FAULT PROTECTORS FOR NETWORK-POWERED BROADBANDCOMMUNICATIONS SYSTEMSIssue Number: 1AUGUST 1, 2002COPYRIGHT 2002 UNDERWRITERS LABORATORIES INC.AUGUST 1, 2002SUBJECT 23892No Text on This PageCONTENTSFOREWORD 4INTRODUCTION1 Scope .52 General
2、 52.1 Units of measurement .52.2 Undated references .5CONSTRUCTION3 General 6PERFORMANCE4 General 65 Samples .76 Test Sequence for Assigned Samples .77 Normal Operation Test 98 Component Temperature Test .109 Limited Short-Circuit Test .119.1 Method .119.2 Results .1210 Endurance Conditioning Test .
3、1210.1 Method .1210.2 Results .1311 Induced Low-Current Test .1312 Variable Ambient Test .1413 Water Spray Test .1414 Dielectric Voltage-Withstand Test .1715 Abnormal Operation Test 1716 Endurance Cycling Test .1817 Jarring Test 18AUGUST 1, 2002 SUBJECT 2389 3FOREWORDA. This Outline of Investigation
4、 contains basic requirements for products covered by UnderwritersLaboratories Inc. (UL) under its Follow-Up Service for this category within the limitations given below andin the Scope section of this Outline of Investigation. They are subject to revision as further experience andinvestigation may s
5、how is necessary or desirable.B. The observance of these requirements by a manufacturer is one of the conditions of the continuedcoverage of the manufacturers product.C. A product which complies with the text of this Outline of Investigation will not necessarily be judged tocomply with the Outline o
6、f Investigation if, when examined and tested, it is found to have other featureswhich impair the level of safety contemplated by these requirements.D. A product that contains features, characteristics, components, materials, or systems new or differentfrom those covered by the requirements in this O
7、utline of Investigation, and that involves a risk of fire orof electric shock or injury to persons shall be evaluated using appropriate additional component andend-product requirements to maintain the level of safety as originally anticipated by the intent of thisOutline of Investigation. A product
8、whose features, characteristics, components, materials, or systemsconflict with specific requirements or provisions of this Outline of Investigation does not comply with thisOutline of Investigation. Revision of requirements shall be proposed and adopted in conformance with themethods employed for d
9、evelopment, revision, and implementation of this Outline of Investigation.E. UL, in performing its functions in accordance with its objectives, does not assume or undertake todischarge any responsibility of the manufacturer or any other party. The opinions and findings of ULrepresent its professiona
10、l judgement given with due consideration to the necessary limitations of practicaloperation and state of the art at the time the Outline of Investigation is processed. UL shall not beresponsible to anyone for the use of or reliance upon this Outline of Investigation by anyone. UL shall notincur any
11、obligation or liability for damages, including consequential damages, arising out of or inconnection with the use, interpretation of, or reliance upon this Outline of Investigation.F. Many tests required by the Outline of Investigations of UL are inherently hazardous and adequatesafeguards for perso
12、nnel and property shall be employed in conducting such tests.AUGUST 1, 2002SUBJECT 23894INTRODUCTION1 Scope1.1 This Outline of Investigation contains construction and test requirements for coaxial fault protectorsthat connect into the underground distribution or feeder cable to a residential unit or
13、 property. Theseproducts are intended for use only with network-powered broadband communication systems employingunderground cable to the premise. These systems permit low power on the center conductor of the coaxialcable. The power limits are in accordance with Article 830 of the National Electrica
14、l Code, NFPA 70.1.2 These requirements are intended for broadband communications circuits employed in the outsideplant which operate in a similar manner to plain old telephone (POT lines) circuits and which encounterthe same environmental problems and are installed in a similar manner to telephone c
15、ircuits.1.3 These requirements are intended for products which connect in series with the coaxial line and obtainoperating power from that circuit. The coaxial fault protector monitors the coaxial circuit for openconditions in the center conductor and for shorts or leakage current to ground from the
16、 center conductor.Leakage current may occur between the coaxial cable center conductor and its shield. The shield shall bebonded to system ground which may also be considered earth ground. The cable shall be typically burieddirectly in the soil (without conduit) less than 18 inches below finished gr
17、ade. This type of installationexposes the cable to environmental problems, mechanical abuse, and tampering. In the event a faultoccurs, the coaxial fault protector shall disconnect the systems operating power to the premises. Normaloperation is the functional process of the product to detect a fault
18、 and disconnect power.2 General2.1 Units of measurement2.1.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.2.2 Undated references2.2.1 Any undated reference to a code or standard appearing in the requirements of the outline sha
19、ll beinterpreted as referring to the latest edition of that code or standard.AUGUST 1, 2002 SUBJECT 2389 5CONSTRUCTION3 General3.1 Products covered by this Outline are in compliance with the construction requirements in the Standardfor Protectors for Coaxial Communications Circuits, UL 497C.3.2 This
20、 type of protection system involves the use of two electronic modules operating as a completesystem; these modules are referred to as the tap-end and premise-end. Each module is located ateach end of the protected cable and communicate with each other to provide the intended protectioncapability of
21、the system. This type of system physically limits the length of protected cable. The followingtest program and other specified requirements are applicable to other technologies designed to providethe same protection for broadband communications underground cable.3.3 In the event of a fault condition
22、, the AC power on the subscriber feeder cable located on theresidential property is to be disconnected. To accomplish this, power is to be disconnected at the serviceproviders end (tap-end) of the circuit. The service provider controls placement of the tap-end module. Thisend is typically installed
23、in a pedestal enclosure, mounted on a utility pole, or some other similartermination point inaccessible to the general public and controlled by the service provider. The subscribermodule is located at the building entrance point, thus establishing the other end of the protected cable.This module wou
24、ld be installed in a network interface box listed in one of the network interface categoriesfor telephone or multimedia communication equipment.3.4 Article 830 in the National Electrical Code, ANSI/NFPA 70, requires mechanical protection for thecable where it leaves the soil, rises, and terminates t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT23892002OUTLINEOFINVESTIGATIONFORCOAXIALFAULTPROTECTORSFORNETWORKPOWEREDBROADBANDISSUENUMBER1

链接地址:http://www.mydoc123.com/p-1069275.html