《UL 62275 CRD-2014 UL Standard for Safety for Cable Management Systems - Cable Ties For Electrical Installations - Section Paragraph Reference 3 7 8 9 10 11 Subject Inclusion of Ty.pdf》由会员分享,可在线阅读,更多相关《UL 62275 CRD-2014 UL Standard for Safety for Cable Management Systems - Cable Ties For Electrical Installations - Section Paragraph Reference 3 7 8 9 10 11 Subject Inclusion of Ty.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): ZODZ, ZODZ2Standard Number: UL 62275Standard Title: Standard for Cable Management Systems Cable Ties for ElectricalInstallationsEdition Date: February 26, 20
3、10Edition Number: 1Section / Paragraph Reference: New 6.2.3DV, Revised 7.1DV.2, 9.1DV.1, 9.1DV.4,9.7.1DV.1 9.7.1DV.3, 9.7.1DV.6, 9.7.2DV.1, 9.7.3DV.1, Figure 5DVSubject: Integrally molded fixing device clarificationDECISION:Add new clause 6.2.3DV D1 as follows:6.2.3 DV D1 Add the following:6.2.3DV.1
4、 A cable tie and fixing device that are manufactured as an integral product shallhave a single Type classification according to either 6.2.1, 6.2.1DV.1 , 6.2.2 or 6.2.2 DV.1.Revise clause 7.1DV.2 as follows:7.1DV.2 The following markings shall be provided on labels, packaging, or installationinstruc
5、tions shipped with the product:. A cable tie and fixing device that aremanufactured as an integral product shall have a single Type designation per 6.2.3DV.1and shall be marked with both the mechanical strength declared for the fixing device andthe loop tensile strength declared for the cable tie. T
6、he declared mechanical strength ofthe fixing device that is integral to a cable tie shall not exceed the declared value for theloop tensile strength of the cable tie.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFixing devices Cable ties Cab
7、le ties with fixing devices as anintegral productMax operating temp for applicationaccording to Table 3Max operating temp for applicationaccording to Table 3Max operating temp for applicationaccording to Table 3Min operating temp for applicationaccording to Table 4aMin operating temp for application
8、according to Table 4Min operating temp for applicationaccording to Table 4Min installation temp if lower than 0C Min installation temp if lower than 0CType designation Type designation Type designationb Minimum and maximum bundle diameter Minimum and maximum bundle diameterMechanical strength as dec
9、lared by themanufacturerLoop tensile strength of the cable tieaccording to Table 2Mechanical strength of the fixing deviceand loop tensile strength of the cable tie,as declared by the manufacturer. If thetwo ratings are the same, a singlecombined rating may be declared. If thetwo ratings differ, bot
10、h shall be declared.aSeparately supplied Type 11 fixing devices need not be marked with the minimum operating temperature. This marking isoptional for such productsbFixing devices that are integral to a cable tie are classified according to the Type for the cable tie.Revise clause 9.1DV.1 as follows
11、:9.1DV.1 The cable tie and/or its associated fixing device shall withstand the stresseslikely to occur during installation and application. A fixing device that is integral to acable tie shall be tested using complete samples. See Clause 5.8. The cable tie shall:a) be capable of fixing the maximum a
12、nd minimum bundle diameter declared bythe manufacturer.Compliance shall be checked by the test specified in 9.2.b) be able to be installed at the minimum temperature declared by themanufacturer.Compliance shall be checked by the test specified in 9.3, for cable ties classifiedaccording to 6.1.2 and
13、6.1.3 only.NOTE This requirement does not apply to cable ties intended to be installed at temperaturesof 0 C or higher.c) be resistant to the effect of impact forces at the minimum operatingtemperature declared by the manufacturer.Compliance shall be checked by the test specified in 9.4, for cable t
14、ies classifiedaccording to 6.1.2 and 6.1.3 only.d) maintain its fixing function at the minimum and maximum applicationtemperature declared by the manufacturer. In Canada and the United States,metallic cable ties shall maintain their fixing function when exposed to vibration.NOTE Non-metallic and com
15、posite cable ties are considered to be resistant to the effects ofvibration.STANDARD NUMBER: UL 62275 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCompliance shall be checked by the relevant tests. Cable ties classifiedaccording to 6.2.1
16、 (Type 1) shall be checked by the tests specified in 9.5. Cableties classified according to 6.2.2 (Type 2) shall be checked by the tests specifiedin 9.6.In Mexico, the vibration test specified in 9.6.4 does not apply.Revise clause 9.1DV.4 as follows:9.1DV.4 The fixing device shall maintain its fixin
17、g function at the minimum and maximumapplication temperature as declared by the manufacturer. See Clause 9.1DV.1.NOTE Separately supplied fixing devices are classified only as Type 2 according to 6.2.2 or, in Canadaand the United States, Type 21 according to 6.2.2DV.1.Compliance shall be determined
18、by the tests specified in 9.7.Replace clause 9.7DV.1 as follows:9.7.1DV.1 A fixing device that is not provided with the means necessary to complete itsassembly in or to a mounting surface shall be fixed firmly to a rigid support according tothe manufacturers instructions. For a separately supplied f
19、ixing device, an appropriatecable tie shall be assembled to the fixing device and then to a non-split mandrelaccording to 5.9. For a fixing device that is integral to a cable tie, the integral tie shall beinstalled on a non-split mandrel according to 5.9. Typical arrangements of the testassembly for
20、 such fixing devices are shown in Figures 5DVA and 5DVC. The mountinghardware used to attach the fixing device to the mounting surface shall not be tested.Revise clause 9.7DV.2 as follows:9.7.1DV.2 A fixing device that is provided with the means necessary to complete itsassembly in or to a mounting
21、surface shall be assembled as intended to an appropriatesurface. For a separately supplied fixing device, an appropriate cable tie shall beassembled to the fixing device and then to a non-split mandrel according to 5.9. For afixing device that is integral to a cable tie, the integral tie shall be in
22、stalled on a non-splitmandrel according to 5.9. Typical arrangements of the test assembly for such fixingdevices are shown in Figure 5DVB.Revise clause 9.7.1DV.3 as follows:9.7.1DV.3 For Type 2 and Type 21 devices, the samples shall be subjected to a tensilepull until the mechanical strength declare
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL62275CRD2014ULSTANDARDFORSAFETYFORCABLEMANAGEMENTSYSTEMSCABLETIESFORELECTRICALINSTALLATIONSSECTIONPARAGRAPHREFERENCE37891011SUBJECTINCLUSIONOFTYPDF

链接地址:http://www.mydoc123.com/p-1068730.html