1、AEROSPACESTANDARDAS412 REV.BIssued 1948-11Reaffirmed 2008-02Revised 2001-07Superseding AS412ACarbon Monoxide Detector InstrumentsFOREWORDChanges in this Revision are format/editorial only.1. SCOPE:This Aeronautical Standard covers the basic type of carbon monoxide detector instrument used to determi
2、ne toxic concentrations of carbon monoxide by the measurement of heat changes through catalytic oxidation.1.1 Purpose:To specify minimum requirements for carbon monoxide detector instruments for use in aircraft, the operation of which may subject the instrument to the environmental conditions specif
3、ied in Paragraph 3.3. This standard is not intended to cover fire detectors.2. REFERENCES:There are no referenced publications specified herein.3. GENERAL REQUIREMENTS:3.1 Material and Workmanship:3.1.1 Materials: Materials shall be of a quality which experience and/or tests have demonstrated to be
4、suitable and dependable for use in aircraft instruments.3.1.2 Workmanship: Workmanship shall be consistent with high grade aircraft instrument manufacturing practice.SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering s
5、ciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaff
6、irmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2008 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, record
7、ing, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE AS412 Revision B- 2 -3.2 Identification:The foll
8、owing information shall be legibly and permanently marked on the instrument or attached thereto:(a) Name of instrument (Carbon Monoxide Detector)(b) SAE Aeronautical Standard AS412B(c) Manufacturers part number(d) Manufacturers serial number of date of manufacture(e) Manufacturers name and/or tradem
9、ark(f) Rating3.3 Environmental Conditions:The following conditions have been established as design requirements only. Tests shall be conducted as specified in Sections 5, 6, and 7.3.3.1 Temperature: When installed in accordance with the instrument manufacturers instructions, the instrument shall fun
10、ction over the range of ambient temperature indicated in Column A below, and shall not be adversely affected by exposure to the temperatures shown in Column B below.3.3.2 Humidity: The instrument shall function and shall not be adversely affected when exposed to any relative humidity in the range fr
11、om 0 to 95 percent at a temperature of approximately 32 C.3.3.3 Altitude: The instrument shall function and not be adversely affected when subjected to a pressure and temperature range equivalent to -1000 feet to 40,000 feet standard altitude except that the instrument temperature shall not be lower
12、 than -30 C.TABLE 1Instrument Location A BHeated Areas (Temp. controlled) -30 to 50 C -65 to 70 CUnheated Areas (Temp. uncontrolled) -55 to 70 C -65 to 70 CSAE AS412 Revision B- 3 -3.3.4 Vibration: When installed in accordance with the instrument manufacturers instructions, the instruments shall fun
13、ction and shall not be adversely affected when subjected to vibrations of the following characteristics:4. DETAIL REQUIREMENTS:4.1 Design:The instrument shall consist of a means for testing air for contamination with carbon monoxide. It shall include an alarm circuit or control circuit which will in
14、dicate the presence of contamination when it reaches a concentration between .005 and .007 percent of carbon monoxide by volume.4.1.1 Sampling Method: A means shall be incorporated in the design to direct the air sample to the sensitive element of the instrument in a positive manner.4.2 Indicating M
15、ethod:The instrument shall be capable of actuating both visual and aural alarm indicators.4.3 Reliability:False signals (including failure) in the instrument shall not result from variations in flight attitude, from normal amounts of gasoline vapors and dust likely to accumulate in the instrument in
16、 normal flight operations, from accelerations encountered in flight or landing, or from variations in voltage (+25 percent, -100 percent of the rated).4.4 Power Variations:All units shall properly function with +10 percent -20 percent variation in DC voltage and/or 10 percent variation in AC voltage
17、 and 5 percent variation in frequency.TABLE 2Type of Instrument Mounting Cycles/MinMaximum DoubleAmplitudeMaximumAccelerationAirframe Structure Mounted 300 - 30,000 .036 inch 10 gShock Mounted Panel or ShockMounted Rack 300 - 3,000 .020 inch 1.5 gSAE AS412 Revision B- 4 -5. TEST CONDITIONS:5.1 Atmos
18、pheric Conditions:Unless otherwise specified, all tests required by this Aeronautical Standard shall be conducted at an atmospheric pressure of approximately 29.92 inches of mercury and at an ambient temperature of approximately 22 C. When tests are conducted with the atmospheric pressure or the tem
19、perature substantially different from these values, allowance shall be made for the variation from the specified conditions.5.2 Vibration:(To minimize friction.) Unless otherwise specified, all tests for performance may be conducted with the instrument subjected to a vibration of 0.002 to 0.005 inch
20、 double amplitude at a frequency of 1500 to 2000 cycles per minute. The term double amplitude as used herein indicates the total displacement from positive maximum to negative maximum.5.3 Vibration Equipment:Vibration equipment shall be used which will provide frequencies and amplitudes consistent w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS412B2001CARBONMONOXIDEDETECTORINSTRUMENTS 一氧化碳 检测 仪器 PDF

链接地址:http://www.mydoc123.com/p-1024344.html