《SAE AS 4115-1989 TEST PLAN FOR THE DIGITAL TIME DIVISION COMMAND RESPONSE MULTIPLEX DATA BUS SYSTEM《数字式时分制指令 响应型多路传输数据总线系统的试验计划》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 4115-1989 TEST PLAN FOR THE DIGITAL TIME DIVISION COMMAND RESPONSE MULTIPLEX DATA BUS SYSTEM《数字式时分制指令 响应型多路传输数据总线系统的试验计划》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、AEROSPACESTANDARDIssued 1989-01AS4115TEST PLAN FOR THE DIGITAL TIME DIVISION COMMAND/RESPONSE MULTIPLEX DATA BUS SYSTEMTABLE OF CONTENTSPARAGRAPH TEST PAGE1. SCOPE 41.1 General 41.2 Application 42. APPLICABLE DOCUMENTS 42.1 Standards, Military 42.2 Other Documents 53. DEFINITIONS 53.1 BC-Bus Control
2、ler 53.2 RT-Remote Terminal 53.3 Message 53.4 Responses 53.4.1 CS-Clear Status 53.4.2 Respond In Form 53.5 Valid Word 53.6 Illegal Bus Traffic 53.7 Backup BC 54. GENERAL TEST REQUIREMENTS 64.1 General Monitoring Requirements 64.2 TDR Considerations 65. DETAILED REQUIREMENTS 65.1 Bus Network Tests 65
3、.1.1 Continuity 75.1.1.1 Shield Continuity 75.1.1.2 Bus Continuity 7Reaffirmed 2011-11RATIONALEThis document has been reaffirmed to comply with the SAE 5-year Review policy. SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engin
4、eering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may
5、be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2011 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, p
6、hotocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provi
7、de feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS4115Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AS4115Page 2TABLE OF CONTENTS(Continued)PARAGRAPH TEST P
8、AGE5.1.1.3 Bus Isolation 85.1.1.4 Transformer-Coupled Stubs 85.1.1.5 Transformer-Coupled Fault Isolation Resistance 85.1.1.6 Transformer-Coupled Isolation 85.1.2 Impedance 95.1.2.1 Bus Impedance 95.1.2.2 Stub Impedance for Transformer-Coupled Stubs 95.1.3 Dynamic Fault Effects 95.1.4 Attenuation 105
9、.1.4.1 Bus Attenuation 105.1.4.2 Bus/Coupler Attenuation 105.1.5 Bus Isolation 105.1.5.1 Redundant Bus Isolation 115.1.5.2 Multiple Bus Isolation 115.1.6 Common Mode Rejection 115.1.7 Distortion 115.1.7.1 Zero Crossing Distortion 125.1.7.2 Waveform Distortion 125.1.7.3 Symmetry 135.1.8 Data Path Int
10、egrity 145.2 System Integration Tests 145.2.1 Introduction 145.2.2 Assumptions 155.2.3 Power Up Sequence 155.2.3.1 RT Power-Up 155.2.3.2 BC Power-Up 155.2.4 Normal Operation 165.2.4.1 Definition 165.2.4.2 Monitor for Proper Sequencing 165.2.4.3 Operational Modes 165.2.4.4 Exercise of Options 165.2.4
11、.4.1 Dynamic Bus Control 165.2.4.4.1.1 Acceptance 165.2.4.4.1.2 Rejection 175.2.4.4.2 Backup BC 175.2.4.4.3 Service Request 175.2.4.4.4 Busy 175.2.4.4.5 Mode Commands 175.2.4.4.6 Emergency Power Operation 175.2.5 Error Monitoring 175.2.6 Error Handling Procedures 185.2.6.1 RT-RT Transfers 185.2.6.2
12、Suppressed Response 185.2.6.3 Power Cycle Test 185.2.6.4 Backup Bus Controller Operation 195.2.6.5 Bus Retries 19Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AS4115Page 3TABLE OF CONTENTS(Continue
13、d)PARAGRAPH TEST PAGE5.2.6.6 Subsystem Reset 195.2.6.7 Bus Switching 195.2.6.8 Illegal Commands 195.2.7 Multiple Bus Architectures 195.2.7.1 Introduction 195.2.7.2 Data Validity 205.2.7.3 Latency 205.2.7.4 Deadlock 205.2.8 Mixing 1553 (USAF), 1553A and 1553B Terminals 205.2.8.1 Status Word Bits 205.
14、2.8.2 Mode Commands 205.2.8.2.1 Defined Mode Commands 205.2.8.2.2 Subaddress/Mode Field 215.2.8.3 Response Time 215.2.8.4 Coupler Variations 215.2.8.5 Voltage Levels 215.2.8.5.1 Output Voltage 215.2.8.5.2 Input Voltage 225.2.8.6 Terminal Address 22LIST OF FIGURESFIGURE TITLE PAGE1 Transformer Couple
15、d Stub DC Resistance 232 Bus Impedance Test Configuration 243 Stub Impedance Test Configuration 254 Bus Attenuation Test Configuration 265 Stub Attenuation Test Configuration 276 Bus Isolation 287 Common Mode Test Configuration 298 Waveform Distortion 309 Output Symmetry 30Copyright SAE Internationa
16、l Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AS4115Page 41. SCOPE:This test plan consists of two major sections for testing of MIL-STD-1553B data bus systems: BusNetwork and System Integration Tests.1.1 General: This test
17、plan defines the test requirements for:a. Verifying that the bus network, (that is, cabling, couplers, connectors and terminators) when in the final system design configuration, complies with the requirements of MIL-STD-1553B.b. Ensuring that when the bus system (that is, bus network, remote termina
18、ls and bus controllers) is integrated, it meets the specific requirements of MIL-STD-1553B, and provides for reliable communications within its system environment.1.2 Application: This is a general test plan for any data bus system designed to meet the requirements of MIL-STD-1553B. These requiremen
19、ts shall apply to the bus system when invoked in a specification or statement of work. The requirements of this test plan may be used in both design verification and production tests.Tests specified herein may be performed in any order unless otherwise noted. For example, to minimize movement of tes
20、t equipment, system tests may be combined with one another or combined with other tests of the system in which the data bus is used.When this test plan is used for design verification, all remote terminal and bus controller designs should have been validated as per the “Validation Test Plan for the
21、Digital Internal Time Division Command/Response Multiplex Data Bus Remote Terminals” and “Validation Test Plan for the Digital Internal Time Division Command/Response Multiplex Data Bus Bus Controllers.”When this test plan is used for production testing, all remote terminal and bus controller equipm
22、ent should have been tested as per the “Production Test Plan for Digital Internal Time Division Command/Response Multiplex Data Bus Remote Terminals” and “Production Test Plan for the Digital Internal Time Division Command/Response Multiplex Data Bus Bus Controllers.”Special requirements such as tho
23、se needed to meet armament bus requirements when specified in the individual system specification may, when within 1553B requirements, replace values or tolerances specified in this test plan for the purpose of generating a system test procedure.2. APPLICABLE DOCUMENTS:2.1 Standards, Military:MIL-ST
24、D-1553 (USAF), Aircraft Internal Time Division Command/Response Multiplex Data Bus, 30 Aug. 1973MIL-STD-1553A, 30 Apr. 1975MIL-STD-1553B, 21 Sept. 1978 with Notice 1, 12 Feb. 1980 and with Notice 2, 8 Sept. 1986Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reprod
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS41151989TESTPLANFORTHEDIGITALTIMEDIVISIONCOMMANDRESPONSEMULTIPLEXDATABUSSYSTEM 数字式 时分 指令 响应 型多路

链接地址:http://www.mydoc123.com/p-1024342.html