REG NASA-LLIS-0914-2000 Lessons Learned Genesis Canister Lift Incident (2000).pdf
《REG NASA-LLIS-0914-2000 Lessons Learned Genesis Canister Lift Incident (2000).pdf》由会员分享,可在线阅读,更多相关《REG NASA-LLIS-0914-2000 Lessons Learned Genesis Canister Lift Incident (2000).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Lessons Learned Entry: 0914Lesson Info:a71 Lesson Number: 0914a71 Lesson Date: 2000-07-20a71 Submitting Organization: JPLa71 Submitted by: Ron Welch/David OberhettingerSubject: Genesis Canister Lift Incident (2000) Abstract: Genesis: In 2000 the Genesis canister detached from a lift fixture fitting
2、just prior to system-level thermal vacuum testing. Fabrication or test organizations should inspect all MGSE for fastener engagement and specified torque prior to delivery for use by a project. Where feasible, threaded components that are to be placed under tension should be designed with a positive
3、 locking device. Flight projects should conduct and document visual and physical inspections of MGSE prior to use. Personnel safety should be addressed, as appropriate, by all procedures. In addition, all test personnel should constantly remain at a safe distance during operations involving suspende
4、d loads.Description of Driving Event: JPL has responsibility for the development, integration, and testing of the payload (including the canister and collector arrays) for the Genesis Project, a mission to collect solar wind particles and return them to Earth. While the Genesis canister was being li
5、fted from the transportation dolly at JPL in preparation for system-level thermal vacuum testing on May 3, 2000, the lift fixture detached at one of the three swivel hoist ring tension fittings.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-refer to
6、 D descriptionDPrior to mounting on the test chamber door, one corner of the canister fell 5 centimeters (2 inches) back onto the dolly. Nearby personnel cushioned the fall, and there was no damage to the Canister or support equipment, or serious injury to personnel. Post-incident inspection reveale
7、d that the threaded fastener had backed out of the fixture and became detached. Additionally, the fasteners at the other tension fittings, and at the upper hoist point, were found only hand-tight.The lift fixture assembly had been proof tested 8 months earlier. The fixture had been reassembled by th
8、e vendor following the proof test and dye penetrant inspection of the swivel hoist fittings. The fixture had last been used to lift the Canister two days prior to this incident. The fixture was visually inspected prior to the May 3, 2000 lift incident, but the hoist rings were not checked for tightn
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS09142000LESSONSLEARNEDGENESISCANISTERLIFTINCIDENT2000PDF

链接地址:http://www.mydoc123.com/p-1018559.html