1、Designation: D1867 07D1867 13 An American National StandardStandard Specification forCopper-Clad Thermosetting Laminates for Printed Wiring1This standard is issued under the fixed designation D1867; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers twelve grades of thermosetting laminate with copper foil bonded
3、 to one or both surfaces. Thesecombination forms are intended primarily for use in fabrication of printed (etched) wiring or circuit boards.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for informationonly.1.3 This standard does not
4、 purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2
5、D709 Specification for Laminated Thermosetting MaterialsD1711 Terminology Relating to Electrical InsulationD3636 Practice for Sampling and Judging Quality of Solid Electrical Insulating MaterialsD5109 Test Methods for Copper-Clad Thermosetting Laminates for Printed Wiring Boards2.2 Other Standards:M
6、IL-P-13949 Plastic Sheet, Laminated, Metal Clad (for Printed Wiring Boards)3NEMA Publication Number LI-143. Terminology3.1 For definitions of terms used in this standard, refer to Terminology D1711.4. Classification4.1 Base Laminate GradesWhere applicable, the dielectric material forming the base of
7、 the copper-clad laminate of the typeslisted in Table 1 and Table 2 shall conform to the property requirements of that specific grade shown in Specification D709.4.2 Copper Foil SurfacesThe surfaces shall be copper foil, either rolled or electrodeposited, having a minimum purity of99.50 % (silver co
8、nsidered as equal to copper). The thickness tolerances of the copper foil shall conform to the requirements ofTable 3.4.3 Thickness Tolerance ClassesCopper-clad laminates are available in two classes of thickness tolerance. Class I representsthose tolerances of standard manufacturing practice. Class
9、 II represents a closer tolerance product than Class I.Any specified classshall conform to the requirements shown in Table 4.4.3.1 For sheets of laminate equal to or greater than 18 by 18 in. (approximately 2.3 ft2) at least 90 % of all thickness testmeasurements made upon any sheet of laminate shal
10、l be within the limits specified in Table 4. For metric size sheets this 90 %requirement shall apply to sheet sizes of 0.5 by 0.5 m or 0.25 m2 area.1 This specification is under the jurisdiction of theASTM Committee D09 on Electrical and Electronic Insulating Materials and is the direct responsibili
11、ty of SubcommitteeD09.07 on Flexible and Rigid Insulating Materials.Current edition approved May 1, 2007Nov. 1, 2013. Published June 2007November 2013. Originally approved in 1961. Last previous edition approved in 20012007 asD1867 01.D1867 07. DOI: 10.1520/D1867-07.10.1520/D1867-13.2 For referenced
12、ASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700
13、 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.4 Available from National Electrical Manufacturers Association, 2101 L St., N.W., Washington, DC 20037.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been ma
14、de to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A
15、Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3.2 The deviation of any single thickness test measurement value (see Practice D3636) from the nominal overall thicknessli
16、sted in Table 4 shall not exceed 125 % of the tolerance listed in Table 4.4.3.3 Any overall laminate thickness not listed in Table 4 shall meet the tolerance requirements of the next highest nominalthickness listed in Table 4.4.3.4 For cut panels (for example, laminate sheets cut to area less than 2
17、.3 ft2 or less than 0.25 m2) at least 98 % of all thicknesstest measurements shall be within the specified overall laminate thickness tolerance values of Table 4.5. Ordering Information5.1 Orders for copper-clad laminates shall specify the grade of laminate base (see 4.1); the type of copper foil (e
18、ither rolled orelectrodeposited); the nominal weight of the copper foil (see 4.2); one- or two-side cladding; nominal overall laminate thickness;and the thickness tolerance class (see 4.3).6. Detailed Requirements6.1 The laminate shall meet the requirements shown in Table 5.7. Warp or Twist7.1 The w
19、arp or twist of copper-clad laminate shall meet the requirements of Table 6. The maximum values shown in Table 6are percentage values applicable only to sheet sizes as manufactured and to sheets cut such that neither length nor width is lessthan 18 in. (457 mm). The values shown are percentages base
20、d upon 36-in. (914-mm) dimension sheets.TABLE 1 Base Laminate GradesNOTE 1 A cross reference table of grade designations (see Table 2)appears here for reference purposes only. The ASTM grades shown aremost closely associated with the NEMA and the military grades listed inthis table. There is no requ
21、irement, stated or implied, in this ASTMspecification that the ASTM grade must meet the specification require-ments of the NEMA or the military standards listed.ASTM Grade TypeXXXP Paper base, phenolic resinXXXPC Paper base, phenolic resinFR-2 Paper base, phenolic resin, flammability ratedFR-3 Paper
22、 base, epoxy resin, flammability ratedFR-4 Glass woven fabric base, epoxy resin, general purpose, flam-mability ratedFR-5 Glass woven fabric base, epoxy resin, temperature resistant,flammability ratedFR-6 Random glass fiber base, polyester resin, flammability ratedG-10 Glass woven fabric base, epoxy
23、 resin, general purposeG-11 Glass woven fabric base, epoxy resin, temperature resistantCEM-1 Glass woven cloth surfaces, cellulose paper core, epoxyresin, flammability ratedCEM-3 Glass woven cloth surfaces, non-woven glass core, flamma-bility ratedTABLE 1 Base Laminate GradesNOTE 1 A cross reference
24、 table of grade designations (see Table 2)appears here for reference purposes only. The ASTM grades shown aremost closely associated with the NEMA and the military grades listed inthis table. There is no requirement, stated or implied, in this ASTMspecification that the ASTM grade must meet the spec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD18672013STANDARDSPECIFICATIONFORCOPPERCLADTHERMOSETTINGLAMINATESFORPRINTEDWIRING 印制电路 镀铜 层压板 标准

链接地址:http://www.mydoc123.com/p-510593.html