1、 NSF Protocol P335 Hygienic Commercial Hand Dryers April, 2007 April 2007 Copyright 2007 NSF International Page i NSF International, an independent, not-for-profit organization, is dedicated to public health safety and protection of the environment by developing standards, by providing education and
2、 by providing superior third-party conformity assessment services while representing the interest of all stakeholders. This Protocol is subject to revision. Contact NSF to confirm this revision is current. Users of this Protocol may request clarifications and interpretations, or propose revisions by
3、 contacting: NSF International 789 Dixboro Road Ann Arbor, MI 48105 Phone: (734) 769-8010Telex: 753215 NSF INTL FAX: (734)769-0109 E-mail: infonsf.org Web: http:/www.nsf.org April 2007 Copyright 2007 NSF International Page ii NSF Protocol P335 Hygienic Commercial Hand Dryers NSF International Engine
4、ering Bacteria and mold present in the retained water is removed or killed before discharge; No objectionable odors shall be detected from the air. 4.4 Product literature Each system shall be accompanied by a comprehensive manual. This may consist of separate documents covering each of the following
5、 sections or may be combined into a single manual with subsections. 4.4.1 Owners manual: The manual or section intended for owner reference shall be written so as to be easily understood by the intended reader and shall include, at a minimum: Model designation; A statement confirming that the system
6、 meets the requirements of NSF Protocol for Hygienic Commercial Hand Dryers; A functional description of system operation, including diagrams illustrating basic system design; A clear statement of the types of environment in which the system may be installed; A list of substances (including cleaners
7、) that, if placed in the system, may adversely affect the system or process; Operating instructions that clearly describe proper function of the system and the operating and maintenance responsibilities of the owner and authorized service personnel; A designation of the length of one operating cycle
8、, if the operating cycle is preset; Clear methods and criteria to be used to identify system malfunctions or problems; A statement instructing the owner to reference the system data plate in the event that a problem arises or service is required; Name and telephone number of an appropriate service r
9、epresentative to be contacted in the event that a problem with the system occurs; Electrical schematics for the system if not appearing on the system itself. 4.4.2 Installation, operation, maintenance, and troubleshooting manual: The manual or sections intended for distribution to authorized represe
10、ntatives shall be written so as to be easily understood by the intended reader and shall include, at a minimum: A numbered list of system components and an accompanying illustration, photograph, or print in which the components are respectively identified; Basic design, construction, and material sp
11、ecifications, for the systems components; Wiring schematics for the systems electrical components; Unpacking instructions including safety considerations, identification of fragile components, and measures to be taken to avoid damage to the system; A sequential installation procedure; Repair or repl
12、acement instructions in the event that a system possesses flaws that would inhibit proper functioning and a list of sources where replacement components can be obtained; A maintenance schedule for all components; April 2007 Copyright 2007 NSF International Page 6 of 11 A sequential method for isolat
13、ing specific component failure. 5 Methods 5.1 System set-up and operation The system shall be installed according to manufacturers instructions for the intended end use. 5.2 Airborne particle reduction under normal operating conditions Testing to determine the effectiveness of the filtration media a
14、nd seals shall be conducted at an aerosol introduction point specified by the manufacturer. 5.2.1 Test procedure The manufacturer shall determine the aerosol induction point that provides the most uniform distribution (reference IEST-RP-CC-O34). Turn on the aerosol photometer and adjust in accordanc
15、e with the photometer manufacturers instructions. Sample the aerosol concentration upstream of the HEPA filter and verify that the concentration gives a light scattering intensity at least equal to that produced by 10 g/L of DOP. For linear readout photometers (graduated 0 100), adjust the instrumen
16、t to read 100 on the 100% scale. For logarithmic readout photometers, adjust the upstream concentration to 1 x 104above the concentration needed to produce one scale division (use the instrument calibration curve). With the nozzle of the probe held not more than 1.0 in (2.5 cm) from the area being t
17、ested, scan the entire downstream side of the HEPA filters, the air discharge point(s), and the seals between the HEPA filter and the hand dryer, by passing the photometer probe in slightly overlapping strokes at a traverse rate of not more than 2 in/sec (5 cm/sec). Record the results. 5.3 Ability t
18、o dry hands within a specified drying time The unit shall be allowed to run for a period of either one operating cycle or 15 seconds, whichever is shorter. This cycle time will be verified to a tolerance of 1 second. A panel of three adult men and three adult women will be randomly selected. The dim
19、ensions of the panel members hands shall be within the dimensions presented by AdultData The Handbook of Adult Anthropometric and Strength Measurements Data for Design Safety. Mean maximum hand spread: measured from the other border of the tip of the little finger to the outer tip of the thumb: Male
20、 212.9 mm 5%; Female 200.2 mm 5%. April 2007 Copyright 2007 NSF International Page 7 of 11 Mean middle finger height: measured from the tip of the middle finger to a line through the wrist crease: Male 193.3 mm 5%, Female 174.9 mm 5%. The test is to be carried out under standard room temperature (23
21、 5C, 73.4 9F) and humidity (55 5%) conditions with climatically conditioned equipment that had been stored in standard room conditions for a minimum of 24 hours. 5.3.1 Test Procedure The user shall remove jewelry (rings, bracelets, watches, etc.) and thoroughly wash their hands using a readily-avail
22、able hand soap and warm water prior to the start of the test. Weigh folded paper towel (Scott Multi-Fold Towels, Product Code 01804, size 23.88 cm x 23.62 cm or equivalent) on a digital scale and record weight. Place hands in bucket containing water (at a temperature of 37C, 98.6F) up to the hand-wr
23、ist crease level for a minimum duration of five seconds, rubbing hands in water to remove air traps and bubbles. Remove hands from bucket and let water drip from hands for five seconds (do not shake) while moving to position under machine. Use the hand dryer as instructed by the manufacturer. If the
24、 manufacturers instructions include rubbing hands together, the user shall rub hands together at the rate of two times per five seconds. When the dryer shuts off, dry excess water from hands (including between fingers and wrist) with the weighed paper towel until hands feel dry. Roll the used paper
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 1人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NSFP3352007HYGIENICCOMMERCIALHANDDRYERS 符合 卫生 要求 商用 干手器 PDF

链接地址:http://www.mydoc123.com/p-1010761.html