1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA LSD 58-2017Air Infiltration Ratings for Recessed LuminairesA NEMA Lighting Systems Division Document LSD 58-2017 Air Infiltration Ratings for Recessed Luminaires Prepared by NEMA Luminaire Section National Electrical Manufac
2、turers Association 1300 North 17thStreet, Suite 900 Rosslyn, Virginia 22209 The requirements or guidelines presented in this document, a NEMA Lighting Systems Division white paper, are considered technically sound at the time they are approved for publication. They are not a substitute for a product
3、 sellers or users own judgment with respect to the particular product discussed, and NEMA does not undertake to guarantee the performance of any individual manufacturers products by virtue of this document or guide. Thus, NEMA expressly disclaims any responsibility for damages arising from the use,
4、application, or reliance by others on the information contained in these white papers, standards, or guidelines. The opinions expressed in this statement represent the consensus views of the member companies of the Lighting Systems Division of the National Electrical Manufacturers Association. The m
5、embers of the Lighting Systems Division manufacture indoor and outdoor lamps, which include: incandescent, fluorescent, light-emitting diode, and solid state lamps, lighting fixtures, and lamp ballasts. www.nema.org 2017 National Electrical Manufacturers Association. All rights, including translatio
6、n into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions. NEMA LSD 58-2017 Page 2 2017 National Electrical Manufacturers Association Introduction Ene
7、rgy codes and ENERGY STARqualification require limiting air infiltration (leakage) through recessed luminaires (fixtures). The goal is to restrict passage of conditioned air and moisture through a recessed luminaire into unconditioned space in order to reduce energy loss and moisture accumulation. B
8、ecause such luminaires are usually installed in the outer envelope of a building in areas that are provided with thermal insulation, they are also typically rated for insulation contact, but the two requirements are not directly related. Many codes allow various routes for compliance with this air i
9、nfiltration requirement: 1) A luminaire construction that passes a test demonstrating limited airflow; 2) Installation of a vapor barrier over the luminaire; or 3) Installation of a sealed box surrounding the luminaire. This paper will focus on the luminaire construction that passes a test demonstra
10、ting limited airflow and will explain the standard test procedure, installation requirements, and labeling applicable to such luminaires. This information is useful for those testing, producing, specifying, installing, and inspecting these luminaires. ASTM E283 Testing ASTM E2831contains the procedu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMALSD582017AIRINFILTRATIONRATINGSFORRECESSEDLUMINAIRESPDF

链接地址:http://www.mydoc123.com/p-994294.html