NEMA C62 61-1993 Gas Tube Surge Arresters on Wire Line Telephone Circuits《电话线路的气体管电涌放电器 修订版ANSI C62 61-1985》.pdf
《NEMA C62 61-1993 Gas Tube Surge Arresters on Wire Line Telephone Circuits《电话线路的气体管电涌放电器 修订版ANSI C62 61-1985》.pdf》由会员分享,可在线阅读,更多相关《NEMA C62 61-1993 Gas Tube Surge Arresters on Wire Line Telephone Circuits《电话线路的气体管电涌放电器 修订版ANSI C62 61-1985》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C62.61-1993Gas Tube Surge Arresterson Wire Line TelephoneCircuits STD-NEMA Cb2.bL-ENGL 3993 b470247 0532753 ANSI C62.61-1993 AMERICAN NATIONAL STANDARD for Gas Tube Surge Arresters on Wire Line Telephone Circuits Secretariat
2、 National Electrical Manufacturers Association Approved by: American National Standards Institute STD-NEMA CbZ-bL-ENGL L993 9 b470247 0512752 388 = Approval of an American National Standard requires verification by ANSI that the requirements for due process, consensus, and other criteria for approva
3、l have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily un
4、animity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. American National Standard The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has app
5、roved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standa
6、rd. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this
7、standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may recei
8、ve current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 1300 N. 17th Street, Rosslyn, Virginia 22209 Copyright O 1996 National Electrical Manufacturers Association All rights reserved No part
9、of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Printed in the United States of America ANSI C62.61-1993 Page Foreword . ii 1 Scope and purpose 2 Referenced and related American National Standards .
10、 1 3 Definitions 1 4 Service . 1 5 Arrester types and classifications 2 6 Design test criteria . 2 7 Classification of arresters-life tests . . . . . . ,. . . . . . . . . . 6 8 Product identification . 1 O 9 Mechanical reliability . 11 CONTENTS Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6
11、Figures Figure 1 Figure 2 Figure 3 Figure 4 Direct current breakdown limits in volts . 2 Insulation resistance (RL) in Ohms (a) . 3 Impulse breakdown in volts . 3 Direct current holdover for two-electrode arresters . ._._. ._. _. . ._. . ._. . . . . . . 4 Direct current holdover for three-electrode
12、arresters . 4 Life criteria for classification of arresters . 7 Acceptable limits for impulse transverse voltage tests 5 One-second 50 or 60 hertz life test circuit (1 ampere-600-foot simulated cable) _._. ._. . ._ ._._._. . . ._._. . . . . . . . . . . 9 One-second 50 or 60 hertz life test circuit (
13、1 ampere-l-mile simulated cable) 9 Thirty-second 50 or 60 hertz life test circuit (0.5 ampere root mean square) . 10 ANSI C62.61-1993 Foreword (This Foreword is not part of American National Standard 62.61-1993) This standard covers gas tube surge arresters to be used for the limitation of voltage s
14、urges due to lightning or power disturbances on wire line telephone circuits. The purpose of the standard is to serve manufacturers and purchasers of gas tube surge amesters by providing technical guidance to ensure the satisfactory operation of these surge arresters in the application intended. Sug
15、gestions for improvement of this standard will be welcome. They should be sent to the National Electrical Manufacturers Association, 1300 North 17th Street, Ross, Virginia 22209. This standard was processed and approved for submittal to ANSI by the American National Standards Committee on Surge Arre
16、sters, C62. Committee approval of the standard does not necessarily imply that all committee members voted for its approval. At the time it approved this standard, the C62 Committee had the following members: Secretariat: National Electrical Manufacturers Association scope: J. L. Koepfinger, Chairma
17、n J. A Gauthier, Secretary Definitions, classifications, ratings, method of test, performance characteristics, physical characteristics, and application of surge arresters of all types. Organization Represented Name of Representabe Association of American Railroads (AARR) . W. Etter Bonneville Power
18、 Administration (BPA) . G. E. Lee Rural Electrification Administration (REA) . G. J. Bagnall Electric Light and Power (EL therefore, all such references have been purposely omitted from this standard. When the terms “minimum values” and “maximum values” are used in this standard, the quality assuran
19、ce agreements between manufacturers and purchaser shall apply. 2 Referenced American National Standards This standard is intended for use in conjunction with the following American National Standards. When these standards are superseded by a revision approved by the American National Standards Insti
20、tute, Inc., the revision shall apply: ANSIAEEE C62.31-1987, Test Specifications for Gas Tube Surge-Protective Devices ANSVNFPA 70-1 990, National Electrical Code 3 Definitions The definitions in ANSVIEEE C62.31-1987 shall apply to the terms used in this standard. 4 Service conditions The limits spec
21、ified in this standard shall be met under the service conditions described in ANSIAEEE C62.31-1987 for the classes and types specified by the manufacturers or purchasers. 1 Previous page is blank ANSI C62.61-1993 DC Breakdown Limits (V) Ali Arresters I I 5 Arrester types and classifications Primary
22、Use A B C D The arresters that are accepted by the purchaser shall be selected in accordance with the arresters primary use as Type A, B, C, or D; and classified in accordance with Section 7 as Class I, II, III, IV, V, VI, or VI1 depending on the requirements specified in the following categories: i
23、mpulse life, maximum single impulse discharge, and alternating current (ac) discharge current-carrying capability. (Lin e-to-G ro u n d ) Multiple-electrode Arresters Initial, End-of-Life (Line-to-Line) Maximum Minimum Maximum Minimum Maximum Minimum Maximum Value Average Value Value Value Value Val
24、ue 300 350 500 180 600 300 1 O00 51 O - 1 O00 250 1200 51 O i 200 265 - 600 265 600 220 - 21 5 - 265 205 265 - - The types of protectors in which the arrester is tested shall be identified, and the classification shall apply only when the arresters are used in those protectors. 6 Design test criteri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMAC62611993GASTUBESURGEARRESTERSONWIRELINETELEPHONECIRCUITS 电话 线路 气体 管电涌放 电器 修订版 ANSIC62611985PDF

链接地址:http://www.mydoc123.com/p-994068.html