NEMA C50 41-2012 Polyphase Induction Motors for Power Generating Stations.pdf
《NEMA C50 41-2012 Polyphase Induction Motors for Power Generating Stations.pdf》由会员分享,可在线阅读,更多相关《NEMA C50 41-2012 Polyphase Induction Motors for Power Generating Stations.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI/NEMA C50.41-2012 Polyphase InductionMotors for PowerGenerating Stations Copyright 2013 by National Electrical Manufacturers Association ANSI/NEMA C50.41-2012 American National Standard Polyphase Induction Motors for Power Ge
2、nerating Stations Secretariat National Electrical Manufacturers Association Approved July 17, 2012 American National Standards Institute, Inc. C50.41-2012 Page ii Copyright 2013 by National Electrical Manufacturers Association Approval of an American National Standard requires verification by ANSI t
3、hat the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Subst
4、antial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; their existence does no
5、t in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances gi
6、ve an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations shall be addressed to the secretariat or sp
7、onsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than
8、five years from the date of approval. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 1300 N. 17th Street, Rosslyn, Virginia 22209 Co
9、pyright 2013 National Electrical Manufacturers Association All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Printed in the United States of America. American National Sta
10、ndard C50.41-2012 Page iii Copyright 2013 by National Electrical Manufacturers Association TABLE OF CONTENTS Foreword ix 1 Scope 1 1.1 Inclusions . 1 1.2 Exclusions 1 2 Applicable Standards . 1 3 Definitions 2 3.1 Design Type . 2 3.1.1 Design NT . 2 3.1.2 Design HT . 2 3.2 Service Factor 2 3.3 Class
11、ification of Insulation Systems 2 4 Service Conditions . 2 4.1 Usual Service Conditions . 2 4.2 Unusual Service Conditions . 2 5 Basis of Rating 4 5.1 Horsepower 4 5.2 Frequency 4 5.3 Speed . 4 5.4 Voltage . 4 6 Horsepower Ratings of Multispeed Motors . 5 6.1 General 5 6.2 Constant Horsepower 5 6.3
12、Constant Torque 5 6.4 Variable Torque . 5 6.4.1 Variable Torque Linear 5 6.4.2 Variable Torque Square 5 7 Insulation Systems 6 8 Service Factor . 6 8.1 Service Factor of 1.0 6 8.2 Service Factor of 1.15 6 8.2.1 General 6 8.2.2 Temperature Rise 6 9 Temperature 7 9.1 General 7 C50.41-2012 Page iv Copy
13、right 2013 by National Electrical Manufacturers Association 9.2 Temperature Rise 7 9.2.1 Barometric Pressure 7 9.2.2 Cooling Air . 7 9.2.3 Reference Ambient Temperature 7 9.2.4 Totally Enclosed Water-Air-Cooled Motors . 8 9.3 Resistance Method for Temperature Measurement 8 9.4 Embedded-Detector Meth
14、od for Temperature Measurement . 8 9.4.1 Resistance Temperature Detectors 8 9.4.2 Locations of Embedded Detectors 8 9.5 Motor Lead Total Temperature 8 10 Torques . 8 11 Starting Requirements . 9 11.1 Starting Capabilities . 9 11.2 Number of Starts 9 11.3 Starting Information Nameplate . 9 12 Load In
15、ertia (Wk2) . 9 12.1 Design NT Motors 9 12.2 Design HT Motors 10 13 Variation from Rated Voltage and Rated Frequency . 10 13.1 Running 10 13.2 Starting . 10 13.2.1 Performance Characteristics . 10 13.2.2 Other Load-Torque Characteristics . 10 13.3 Momentary Operation 11 13.4 Effects Of Unbalanced Vo
16、ltages On The Performance Of Polyphase Squirrel-Cage Induction Motors . 12 13.4.1 Effect on Performance - General 13 13.4.2 Voltage Imbalance Defined . 13 13.4.3 Torques . 13 13.4.4 Full-Load Speed 14 13.4.5 Currents . 14 14 Bus Transfer or Reclosing . 14 14.1 General 14 14.2 Slow Transfer or Reclos
17、ing 14 14.3 Fast Transfer or Reclosing 15 14.4 Recommendations . 15 15 Power Factor Correction 16 C50.41-2012 Page v Copyright 2013 by National Electrical Manufacturers Association 15.1 Corrective KVAR 17 15.2 Capacitors 17 15.3 Autotransformer Starters . 17 16 Efficiency . 17 17 Stator current puls
18、ations 17 18 Surge Capabilities of AC Winding with Form-Wound Coils. 18 18.1 General 18 18.2 Surge Capacitors . 18 18.3 Stator Windings . 18 18.4 Method of Test . 18 18.5 Test Voltage Adjustment 19 19 Motors Operating on an Ungrounded System . 19 20 Occasional Excess Current . 19 21 Operation of Ind
19、uction Motors from Variable-Frequency or Variable-Voltage Power Supplies, or Both 19 22 Belt, Chain, and Gear Drive . 19 23 Aseismatic Capability 19 23.1 Earthquake Damage 19 23.2 System Requirements . 20 23.3 Motor Requirements 20 23.4 Supporting Base Structure . 20 24 Airborne Sound 20 24.1 Sound
20、Quality 20 24.2 Sound Measurement . 20 24.3 Sound Power Levels 21 25 Bearings 23 25.1 Horizontal Motors . 23 25.2 Vertical Motors . 23 25.3 Oil Lubrication 23 25.4 Antifriction Bearings . 23 25.5 Shaft Currents 23 26 Lubrication System 23 26.1 Supplied From the Driven Equipment System . 23 26.2 Auxi
21、liary Lubrication System 23 27 Overspeed . 24 28 Construction Features . 24 28.1 Protection of Motor Leads from Mechanical Damage . 24 28.2 Drainage 24 C50.41-2012 Page vi Copyright 2013 by National Electrical Manufacturers Association 28.3 Cooler-Tube Leakage 24 28.4 Space Heaters . 24 28.5 Horizon
22、tal Sleeve Bearing Motors . 24 28.6 Grounding 24 29 Terminal Housing and Boxes 25 29.1 General 25 29.2 Dimensions and Volumes 25 29.3 Accessory Leads 25 30 Coupling End Play and Rotor Float . 25 30.1 General 25 30.2 Flexible Couplings 25 30.3 Assembly . 25 31 Motor Vibration 25 31.1 General 25 31.2
23、Limits . 28 31.3 Reed Frequency of Vertical Motors . 28 31.3.1 Static Deflection 28 31.3.2 Radial Resonant Frequency 28 31.3.3 Determining System Resonant Frequency 28 32 High-Potential Tests 29 32.1 Safety Precautions and Test Procedure 29 32.2 Test Voltage . 29 33 Motor with Sealed Windings Confor
24、mance Tests 29 33.1 Test for Stator Which Can Be Submerged 29 33.2 Test for Stator Which Cannot Be Submerged . 29 34 Tests on Complete Motors 30 34.1 General 30 34.2 Tests on Motors Completely Assembled in the Factory 30 34.2.1 Required Factory Tests . 30 34.2.2 Optional Tests . 30 34.3 Tests on Mot
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMAC50412012POLYPHASEINDUCTIONMOTORSFORPOWERGENERATINGSTATIONSPDF

链接地址:http://www.mydoc123.com/p-994067.html