NAVY UFGS-08 34 63-2011 DETENTION HOLLOW METAL FRAMES DOORS AND DOOR FRAMES《拘留空心金属框架 门和门框》.pdf
《NAVY UFGS-08 34 63-2011 DETENTION HOLLOW METAL FRAMES DOORS AND DOOR FRAMES《拘留空心金属框架 门和门框》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-08 34 63-2011 DETENTION HOLLOW METAL FRAMES DOORS AND DOOR FRAMES《拘留空心金属框架 门和门框》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 34 63 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 34 63 (April 2006)UFGS-11193 (September 1999)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08
2、34 63DETENTION HOLLOW METAL FRAMES, DOORS, AND DOOR FRAMES05/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLING1.4 HARDWARE COORDINATION CONFERENCEPART 2 PRODUCTS2.1 MATERIALS2.1.1 Hot-Rolled Carbon Steel2.1.2 Cold-Rolled Carbon Steel2.1.3 Galvanized Steel2.2 DETENTION H
3、OLLOW METAL DOORS AND FRAMES2.2.1 Door Fabrication2.2.2 Door and View Window Frame Fabrication2.2.3 Door Reinforcement for Hardware2.2.4 Frame Reinforcement for Hardware2.2.5 Factory Finishing2.3 ACCESS PANELS2.4 OPENING PROVISION2.5 SOURCE QUALITY CONTROLPART 3 EXECUTION3.1 INSTALLATION3.1.1 Door S
4、chedule3.1.2 Frames3.1.3 Doors3.1.4 Access Panels3.2 ADJUSTMENT AND CLEANING- End of Section Table of Contents -SECTION 08 34 63 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 34 63 (May 2011)-Preparing
5、Activity: NAVFAC SupersedingUFGS-08 34 63 (April 2006)UFGS-11193 (September 1999)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 08 34 63DETENTION HOLLOW METAL FRAMES, DOORS, AND DOOR FRAMES05/11*NOTE: This guide specification covers the requirem
6、ents for detention hollow frames, metal doors and door frames for use in brigs and detention facilities in locations where prisoners may have access.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project sp
7、ecification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not bracke
8、ts are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: The following information shall be shown on the project drawings:1. Sizes of door or view window, speaking port, louver, view port a
9、nd food pass, if any, openings, thicknesses of doors, swings, and travels of doors.2. Indicate detention hollow metal doors as “Sec. Holl. Mtl.“ or “SHM“ and show that the term means “Detention Hollow Metal Doors and Frames,“ in a schedule of abbreviations.3. The size of wall or partition where door
10、 is to be located.SECTION 08 34 63 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4. Type and thickness of glazing required.5. Method, type, and spacing required for anchoring frames to adjoining construction.6. Include a complete door schedul
11、e. The door schedule should assign a separate number for each opening and should indicate the door type and style, material, design, size, thickness, hardware set number, threshold material, if any.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text
12、of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automaticall
13、y place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print p
14、rocess.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM A1008/A1008M (2010) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural,
15、 High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake HardenedASTM A1011/A1011M (2010) Standard Specification for Steel, Sheet, and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formabili
16、ty and Ultra-High StrengthASTM A653/A653M (2010) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessSECTION 08 34 63 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AS
17、TM G 60 (2001; R 2007) Conducting Cyclic Humidity ExposuresNATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)NAAMM HMMA 863 (2004) Guide Specifications for Detention Security Hollow Metal Doors and Frames1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01
18、33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals a
19、re already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approv
20、al on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Di
21、vision or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose th
22、e second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office tha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0834632011DETENTIONHOLLOWMETALFRAMESDOORSANDDOORFRAMES 拘留 空心 金属 框架 门框 PDF

链接地址:http://www.mydoc123.com/p-984739.html