1、 INCH-POUND MIL-STD-2003A(SH) 3 September 2009 SUPERSEDING DOD-STD-2003 24 June 1987 DEPARTMENT OF DEFENSE STANDARD PRACTICE ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES AMSC N/A AREA SESS Provided by IHSNot for ResaleNo reproduction or networking permitted without l
2、icense from IHS-,-,-MIL-STD-2003A(SH) FOREWORD 1. This standard is approved for use by the Naval Sea Systems Command, Department of the Navy and is available for use by all Departments and Agencies of the Department of Defense. 2. This standard disseminates up-to-date information detailing requireme
3、nts for standard installation methods (non-fiber optic cable) employed for submarine and surface ship electrical distribution systems. Utilize MIL-STD-2042 (Fiber Optic Cable Topology Installation Standard Methods for Naval Ships) for detailed information and guidance involving the installation of f
4、iber optic cable on Naval surface ships and submarines. 3. These criteria apply to work on a specific ship or ships only when invoked by the Ship Specifications or similar contractual documents. 4. These criteria are for application to new construction, conversion, and alteration of existing ships.
5、5. Considering the magnitude of this standard, along with the changing requirements imposed on the Electric Plant, it is inevitable that changes will be required to update these criteria. Therefore, as comments arise, they should be forwarded to Naval Sea Systems Command (NAVSEA) 05Z3 to keep this s
6、tandard as current as possible through subsequent revisions. Revisions will be accomplished by the issuance of additional or revised figures to be inserted in the basic standard parts. Superseded pages may be retained for reference if so desired. 6. Comments, suggestions, or questions on this docume
7、nt should be addressed to Commander, Naval Sea Systems Command, ATTN: SEA 05M2, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to CommandStandardsnavy.mil, with the subject line “Document Comment”. Since contact information can change, you may want to verify the
8、 currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. ii Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2003A(SH) 1. SCOPE 1.1 Scope. This standard covers shipboard installation requirements for
9、 electrical cable, equipment, penetrations, cableways, and connectors. This standard consists of this general standard and five parts as follows: Part 1 (Cable) Preparation and end-sealing, entry to equipment and connectors, repair and splicing. Part 2 (Equipment) Equipment mounting, switchboard mou
10、nting, battery equipment, casualty power, and shore power. Part 3 (Penetrations) Swage tubes, stuffing tubes, kickpipes, surface ships and submarines, hull penetration, and general. Part 4 (Cableways) General, submarine, surface ship and cable protection. Part 5 (Connectors) Cable and conductor prep
11、aration in accordance with MIL-C-81511, MIL-DTL-5015, MIL-DTL-26482, MIL-DTL-28840, MIL-DTL-22992, and MIL-DTL-38999 connectors. 1.2 Application. Electrical plant installation methods parts 1 through 5 are to be used by all installing activities. These parts do not identify ship or type, but do esta
12、blish minimum standards of acceptance for Naval ships. It is the responsibility of the user activity to determine which part satisfies their requirements. It does not authorize relaxation of any requirement specifically invoked by new construction, conversion, overhaul, or refurbishment contracts. I
13、n instances where deviated design requirements (for example, ship type, ship class, and so forth) conflict, the requirements of this standard govern. Any deviation for electric plant installation identified in this standard is to be submitted to NAVSEA 05Z3 for resolution. 2. APPLICABLE DOCUMENTS 2.
14、1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this standard. This section does not include documents cited in other sections of this standard or recommended for additional information or as examples. While every effort has been made to ensure the completenes
15、s of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this standard, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, a
16、nd handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-5015 - Connectors, Electrical, Circular Threaded, AN Type, General Specifi
17、cation for MIL-DTL-22992 - Connectors, Plugs and Receptacles, Electrical, Waterproof, Quick Disconnect, Heavy Duty Type, General Specification for MIL-DTL-26482 - Connectors, Electrical, (Circular, Miniature, Quick Disconnect, Environment Resisting), Receptacles and Plugs, General Specification for
18、MIL-DTL-27599 - Connectors, Electrical, Circular, Miniature, High Density, Quick Disconnect, Environment Resistant, Solder Contacts, General Specification for MIL-DTL-28840 - Connectors, Electrical, Circular, Threaded, High Density, High Shock, Shipboard, Class D, General Specification for 1 Provide
19、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2003A(SH) MIL-DTL-38999 - Connectors, Electrical Circular, Miniature, High Density, Quick Disconnect (Bayonet, Threaded and Breech Coupling), Environment Resistant, Removable Crimp and Hermetic Solder
20、Contacts, General Specification for MIL-C-81511 - Connectors, Electrical, Circular, High Density, Quick Disconnect, Environment Resisting: and Accessories General Specification for DEPARTMENT OF DEFENSE STANDARDS MIL-STD-2003-1 - Electric Plant Installation Standard Methods for Surface Ships and Sub
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILSTD2003A2009ELECTRICPLANTINSTALLATIONSTANDARDMETHODSFORSURFACESHIPSANDSUBMARINES 水面 舰船 潜艇 电气设备

链接地址:http://www.mydoc123.com/p-982358.html