1、flIL-fl-272Ll1 65 U 9977906 02593h2 7 MIL-M-29241 10 MAY 1985 MILITARY SPECIFICATTON MATERIAL HANDLING UNITS FOR MEDICAL FACILITIES, PERFORMANCE SPECIFICATIONS FOR This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This performanc
2、e specification covers modular wall hung material handling units for medical facilities. 1.2 Classification. The material handling units specified here include storage units, distribution carts, and rail support systems. 1.2.1 Type I, storage and distribution units. Units shall have the following us
3、age. a. Clean linen storage and distribution unit, including four shelves b. and one deep drawer. Medical and surgical supplies storage and distribution unit including three shelves, three deep drawers and five shallow drawers. Pharmaceutical and biologicals storage and distribution units, including
4、 80 cassettes. Non-medical supplies storage and distribution unit including three shelves, three deep drawers and five shallow drawers. c. d. 1.2.1.1 Dl.mensions. The Type I storage units shall have the following external limiting dimensions. Width: Minimum of 22 inches and a maximum of 24 inches. D
5、epth: Minimum of 19 inches and a maximum of 24 inches. Height: Minimum of 60 inches and a maximum af 66 inches, Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commanding Officer (Code 156), Nav
6、al Construction Battalion Center, Port Hueneme, CA 93043, by using the self-addressed Standardization pocument Improvement Proposal (DD Form 1426) appearing at the end of this dacument or by letter. a l I - h i FSC 6530 THIS DOCUMENT CONTAINS 12 PAGES Provided by IHSNot for ResaleNo reproduction or
7、networking permitted without license from IHS-,-,-MIL-M-272Ll1 65 = 9779906 0257363 9 W MIL-M-29241 1.2.2 Type II. distribution carts. Will be used to move and hang wall hung storage and distribution units. 1.2.2.1 Capability. Carts shall be capable of raising fully loaded units onto and lowering th
8、em from rails and transporting them to and from point of use. 1.2.3 Type III, support system. Shall include: a, Rails b. Rail hangers or fasteners 1.2.3.1 Rails and rail hangers or fasteners. Storage and distribution unit support rails shall be capable of being installed at any height above the floo
9、r and shall be shaped to securely engage the support hooks on the back of Type I storage and distribution units. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specification and standards. Unless otherwise specified, the following specifications and standards of the issue listed in that iss
10、ue of the Department of Defense Index of Specifications and Standards (DODISS) specified in the solicitation form a part of this specification to the extent specified herein. STANDARDS MIL IT ARY MIL-STD-129 - Marking for Shipment and Storage, 2.2 Other publications. The following documents form a p
11、art of this specification to the extent specified herein. AMERICAN NATIONAL STANDARDS INSTITUTE, INC. (ANSI) A156.11 - Auxiliary Locks. (Application for copies should be addressed to the American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018.) NATIONAL ELECTRICAL MANUFACTURER
12、S ASSOCIATION (NEMA) LD3-1980 - High Pressure Decorative Laminates. (Application for copies should be addressed to the National Electrical Manufacturers Association, 2101 L Street, N.W., Washington, DC 20037.) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
13、m IHS-,-,-MIL-M-2724L 65 9 777770b 0257364 O m MIL-M-29241 NATIONAL SANITATION FOUNDATION (NSF) a 3 No. 30 - Cabinetry and Laboratory Furniture, 1980. (Application for copies should be addressed to National Sanikary Foundation, 3475 Plymouth Road, P. O. Box 1468, Ann Arbor, MI 48106.) (Industry asso
14、ciation specifications and standards are generally available from reference libraries. Federal agencies.) They are also distributed among technical groups and 2.3 Order of precedence. If there is a conflict between the text of this specification and the references cited, the text of this specificati
15、on shall take precedence. - 3. REQUIREMENTS 3.1 Description. The modular material handling and storage units and the distribution carts, and rail support system to be provided under this performance specification shall be so designed and constructed as to meet the requirements of this section of the
16、 specification. shown in paragraph 1.2.1.1. Units shall be sized as 3.2 Manufacturers performance requirements. The manufacturer shall provide units that are standard commercial products conforming to the design and installation requirements. 3.2.1 Standard commercial product. The material handling
17、units shall be in accordance with the requirements of this specification and shall be the manufacturers standard commercial product. Additional or better features that are not prohibited by this specification but are a part of the manufacturers standard commercial product shall be included in the un
18、its. A standard commercial product is a product that has been sold or is being offered for sale on the commercial market through advertisements, manufacturers catalogs, or brochures and represents the latest production model. 3.2.2 Design. Minor deviations from the specified dimensions will not be c
19、onsidered cause for rejection provided the item is suitable for the purpose intended and is the manufacturers cataloged stock product substantially equivalent to the item described. The manufacturer shall have no design prerogatives or deviations differing from the requirements and options specified
20、 unless such deviations are numbered, notated, and described by the manufacturer and approved by the contracting officer. 3.2.3 Installation. The manufacturer shall provide the Type I storage units and the Type II distribution carts. fasteners of the Type III support system shall be provided and ins
21、talled in the specific locations indicated by the contracting officer or his representative. The rails and rail hangers or 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-_- MIL-M-27241 65 W 9797906 0257365 2 M HIL-H-24S41 3.3 Modularity. The Type
22、I storage units shall be modular in that they shall be interchangeable in position on the support rails and shall occupy a linear space along the support rails of no more than 24 inches. be interchangeable with drawers. 12 foot lengths that can be cut or spliced with simple hand tools. Shelves shall
23、 The support rails shall be of modular 3.4 Movability. Wall hung Type I units shall be moveable from one area to another on distribution carts that are designed to position units on the rails or remove them from the rails. placed, and secured by no more than one unskilled person without tools. Type
24、I units shall be designed to be moved, 3.5 Adjustabilitp. Rail mounting shall be at any height above the floor so that Type I storage units may be adjustable vertically. units shall have vertical adjustability of shelves, drawers, or trays throughout the height of the unit in increments no greater t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILM292411985PERFORMANCESPECIFICATIONSFORMATERIALHANDLINGUNITSFORMEDICALFACILITIES 用于 医疗 设施 材料 调节

链接地址:http://www.mydoc123.com/p-980364.html