NAVY MIL-M-28942-1970 MULTIMETER PORTABLE BATTERY POWERED AN USM-123A《AN USM-123A型便携式电池电源万用表》.pdf
《NAVY MIL-M-28942-1970 MULTIMETER PORTABLE BATTERY POWERED AN USM-123A《AN USM-123A型便携式电池电源万用表》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-M-28942-1970 MULTIMETER PORTABLE BATTERY POWERED AN USM-123A《AN USM-123A型便携式电池电源万用表》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-M-28942 (MC) 3 February 1970 SUPERSEDING See Section 6. MI LI TARY SP ECi F IC AT i ON MULTIMETER: PORTABLE, BATTERY POWERED, AN/USM-l23A 1. SCOPE 1.1 This specification covers the requirements for one type multimeter used for the measurement of alternating current (ac) and direct current (dc) v
2、oltages, dc current, and resistance. 2. APP LICAB LE DOCUMENTS 2.1 for bids or request for proposal, form a part of the specification to the extent specified herein. The following documents, of the issue in effect on date of invitation SP EC i Fi CAT I O NS F ED ERAL P P P - B-636 -Box, Fiberboard.
3、Mi LI TARY MI L-M-14 -Mo Id ing Plastics and Mo Ided . Plastic.Parts, Thermosetting. MI L-P-116 -Preservation, Methods of. MI L-S-6872 -Soldering Process, General Specification for. MI L-M-16034 -Meters, El ec trica I -Ind ica ti ng (Switchboard and Portable Types). / STANDARDS MI LI TARY MI L-STD-1
4、05 -Sampling Procedures and Tables for inspection by Attributes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-M-287LI2 bb m 7977706 033b5b3 5 m MIL-M-28942 (MC) MI L-STD-129 -Marking for Shipment and Storage. (Copies of specifications and stan
5、dards required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 3. REQUIREMENTS 3.1 First article. As soon as practicable after award of contract or order, and prior to starting production, the m
6、anufacturer shall submit three first articles to the contracting officer or his authorized representative for examination and approval. Each first article shall be complete with calibration procedures. The first articles shall be representative of the construction, workmanship, components, and mater
7、ials to be used during production. Approval of the first articles does not precludethe requirements for performing the quality conformance inspection. 3.2 Material. The material for each part of the. multimeter shall be as specified herein. When a definite material is not specified, a material shall
8、 be used which is adequate for the purpose intended and for meeting the requirements specified herein. Acceptance or approval of any constituent material for a particular part shall not be construed as a quaranty of the acceptance of the finished product. 3.2.1 Case material. Molded thermosetting pl
9、astic material of medium to high impact type conforming to Mi L-M-14 shall be used for the case. The material shall be of the proper type for the intended use. 3.2.2 Components and parts. Electrical and electronic components and parts used in the multimeter shall show no evidence of mechanical or el
10、ectrical breakdown, deterioration, corrosion, or breakage as a result of any requirements herein and shall be adequate for the purpose intended. 3.3 Design and construction. This specification covers a self-contained, portable, multiple-function meter, Multimeter AN/USM-l23A. The multimeter shall be
11、 used for the measurement of dc voltages to 4,000, ac voltages to 800, the ac portion of output voltages to 160, volume levels to 45 decibels (dB), dc amperes to 8, and resistances to 200 megohms. The multimeter shall be housed in a nonmetallic case with a carrying handle attached. The multimeter sh
12、all be supplied with a suitable pair of plug-in test leads, removable alligator clips, a 4,000-volt o/) probe extension for use with the test leads. The meter dial shall be a minimum of 6 inches arc length. The multimeter shall be powered by one or more dry-cell batteries of adequate capacity - Prov
13、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-M-28942 (MC) for operation of the resistance measurement section which shall be contained within the case. No external power source shall be required. 3.3.1 Circuitry. All circuitry shall exhibit suffic
14、ient stability to maintain calibration withmable tolerances specified herein, without resetting any internal controls during performance requirements tests. 3.3.2 External controls and connectors. External controls and connectors shall be keptto a reasonable minimum. External controls and connectors
15、 shall be designed and posi tioned to afford maximum convenience, minimum projection from surface of case, and maximum conformance to the physical.configuration of the multimeter. External controls and connectors shall include, but not be limited to, the fol lowing: (a) Range selector switch (b) Fun
16、ction selector switch (c) Ohm zero-adjust control (d) Test lead connectors. Any combination of switches may be provided to obtain the stated requirements. 3.3.2.1 Selector switches. Range and function selector switches shall be suitably indexed and marked so that the correct scale can be easily sele
17、cted. Selector switches shall be designed to eliminate danger of electric shock to the operator., Selector switches shall have a life of 10,000 continuous no-load operations, when tested as specified in 4.5.7. 3.3.2.2 Ohms zero adjust control. An ohms zero adjust control shall be provided on the fro
18、nt panel of the instrument to adjust the meter pointer to zero on each ohms range when the function selector switch and the range selector switch are set to ohms and the ohmmeter leads are shorted. 3.3.2.3 Lead connectors. Lead connectors shall be of the type to receive banana spring-tip plugs. Lead
19、 connectors shal I maintain positive electrical and mechanical contact with the test leads after 25 repeated withdrawals of the test leads when tested as specified in 4.5.8. 3.3.3 durability. The case shall be equipped with a suitable carrying handle for con- venience in transportability. The case s
20、hall be designed to permit convenient Case. The multimeter shall be housed in a molded case of.suitable Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-M-28742 bb m 777770b OL3b565 7 W MI II-M- 28 942 (MC) accessability to the interior of the mul
21、timeter for service and repair, including battery replacement. 3.3.4 Dial. The dial face shall be a minimum 6-1/2 inches wide. Arc length of longest scale shall be 6 inches minimum. The pointer shall be of suitable size and material for the intended purpose. The dial shall b covered with a pro- tect
22、ive glass window or other suitable material of sufficient strength to afford desired protection to the dial. Window material and means of securing shall be in accordance with MI L-M-16034. - 3.3.5 Test leads. One pair of test leads shall be supplied with the multi- meter. The test leads shall be col
23、or coded, one red and one black. One end of each test lead shall be fitted with suitable test prods. Alligator clips shall be pro- vided which can be securely and quickly fitted over the test prods. The high voltage test prod shall be designed for easy attachment and for maximum protection to the op
24、erator against electrical shock. The opposite end of each test lead shall be fitted with a banana spring-tip plug. Fit of test leads into leadzonnectors of the multimeter shall meet the test specified in 4.3.4.5. 3.3.6 Soldering. Soldering of electrical connections shall be in accordance with MI L-S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILM289421970MULTIMETERPORTABLEBATTERYPOWEREDANUSM123AANUSM123A 便携式 电池 电源 万用表 PDF

链接地址:http://www.mydoc123.com/p-980362.html