NAVY MIL-M-23677 A-1987 METER AMPERE-HOUR (NONMERCURY TYPE)《安培小时测量仪表(非水银类)》.pdf
《NAVY MIL-M-23677 A-1987 METER AMPERE-HOUR (NONMERCURY TYPE)《安培小时测量仪表(非水银类)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-M-23677 A-1987 METER AMPERE-HOUR (NONMERCURY TYPE)《安培小时测量仪表(非水银类)》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、- MIL-M-23b77A bb W 777770b 0332370 T c -e I F-61- 0-7 MIL-M-23677A( Si) 20 July 1987 SUPEKSEDING MI L-kl-2 3 6 7 7 ( S HIPS ) 16 September 1963 (See 6.7) MILITARY SPECIFICATION METER, AMPERE-HOUR (NONMEKCURY TYPE) This specification is approved for use within the Naval Sea Systems Command, Departme
2、nt of the Navy, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers ampere-hour meters used to record the energy that enters or leaves a submarine storage battery. 1.2 Classification. Ampere-hour meters shall be classif
3、ied as follows: Type I - Designed to operate from a 2500-ampere, 100-millivolt (mV) Type II - Designed to operate from a 3OO0-amperey 100-mV shunt. Type III - Designed to operate from a 4OO0-amperey 100-mV shunt. Type IV - Designed to operate from a 5OO0-amperey 100-mV shunt. shunt. 2. APPLICABLE DO
4、CUMENTS 2.1 Government documents. 2.1.1 Specifications and standard. The following specifications and stan- dard form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Department of Defense
5、 Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 5523,
6、 Department of the Navy, Washington, DC 20362-5101 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 6625 DISTRIBUTION STATEMENT A Approved for public release; distribution unlimited Provided by I
7、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IYIIJ-M-23677A( SH) SPECIFICATIONS MIL IT ARY MIL-S-90 1 - Shock Tests, H.I. (High Impact); Shipboard Machinery, Equipment and Systems, Requirements for. (Naval Shipboard Use). MIL-E-9 17 - Electric Power Equipment,
8、 Basic Requirements DOD-D-1000 - Drawings, Engineering and Associated Lists. MIL-E-2036 - Enclosures for Electric and Electronic Equipment, MIL-P-15024 - Plates, Tags and Bands for Identification of MIL-P-15024/5 - Plates, Identification. MIL-M-15071 - Manuals, Technical: Equipment and Systems, Con-
9、 tent Requirements for. MIL-M-16034 - Meters, Electrical-Indicating (Switchboard and Portable Types). MIL-E-16400 Equipment, Naval Ship and Shore: General Specification for. MIL-E-17555 - Electronic and Electrical Equipment, Accessories, and Provisioned Items (Repair Parts): Packaging of. Types, and
10、 Associated Accessories, General Specification for. Naval Shipboard. Equipment. - Electronic Interior Communication and Navigation MIL-T-55164 - Terminal Boards, Molded, Barrier Screw and Stud STANDARD MILITARY MIL-STD-167-1 - Mechanical Vibrations of Shipboard Equipment, (Type I - Environmental and
11、 Type II - Internally Excited). (Copies of specifications and standards required by contractors in connec- tion with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting activity.) 2.2 Other publications. The following document forms a par
12、t of this speci- fication to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted shall be those listed in the issue of the DoDISS specified in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS shall b
13、e the issue of the nongovernment docu- ments which is current on the date of the solicitation. UNIFORM CLASSIFICATION COMMITTEE AGENT Uniform Freight Classification Ratings, Rules and Regulations (Application for copies should be addressed to the Uniform classification Committee Agent, Tariff Public
14、ation Officer, Room 1106, 222 South Riverside Plaza, Chicago, IL 60606.) w a a a 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-L . MIL-M-23677A bb 7979706 O332372 3 E c , MIL-M- 2 36 7 7A ( SH) (Nongovernment standards and other publications are
15、normally available from the organizations which prepare or which distribute the documents. These documents also may be available in or through libraries or other informational services. ) 2.3 Order of precedence. In the event of a conflict between the text of this specification and the references ci
16、ted herein (except for associated detail specifications, specification sheets or MS standards), the text of this speci- fication shall take precedence. Nothing in this specification, however, shall supersede applicable laws and regulations unless a specific exempt ion has been obtained. 3 REQUIREMEN
17、TS 3.1 First article. When specified in the contract or purchase order, a sample shall be subjected to first article inspection (see 4.4 and 6.3). 3.2 Materials. Materials used in the construction of the ampere-hour meters shall be as specified herein. 3.2.1 Prohibited materials. 3.2.1.1 Mercury. Th
18、e use of the element mercury in any component parts of the meter and for any manufacturing process shall be prohibited. 3.2.1.2 Thermionic devices. The use of thermionic devices such as electron tubes is prohibited. 3.2.2 Recovered materials. Unless otherwise specified herein, all equipment, materia
19、l, and articles incorporated in the products covered by this specification shall be new and may be fabricated using materials produced from recovered materials to the maximum extent practicable without jeopardizing the intended use. The term “recovered materials“ means materials which have been coll
20、ected or recovered from solid waste and reprocessed to become a source of raw materials, as opposed to virgin raw materials. None of the above shall be interpreted to mean that the use of used or rebuilt products is allowed under this specification unless otherwise specifically specified. 3.3 Design
21、. The ampere-hour meter shall consist of two major components as follows: (a) Integrating unit. An integrating unit consisting of electrical and electronic parts arranged to permit device performance as specified herein shall be provided. The parts shall be as- sembled and wired on a sub-panel not t
22、o exceed 10 inches in length and a cubic content not to exceed 640 cubic inches. The sub-panel shall be for mounting within a switchboard but shall be mounted within a bulkhead-mounted, dripproof enclosure as specified in 3.4.3. (b) Indicator. A four-digit unidirectional electric cyclometer shall be
23、 used as the indicator. The counter shall be capable of being reset to zero. The figures on the counter shall be black on a white background and shall be not less than 3/16 inch high and 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-M-23b77A
24、 66 = 777770b 0132173 5 1/8 inch wide. The counter shall be mounted on a panel suitable for flush mounting on a switchboard. The dimensions of this panel shall not exceed the cross section dimensions specified for 4-1/2-inch switchboard meters under MIL-M-16034. The indicator shall not exceed 4 inch
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILM23677A1987METERAMPEREHOURNONMERCURYTYPE 安培 小时 测量 仪表 水银 PDF

链接地址:http://www.mydoc123.com/p-980338.html