《NAVY MIL-DTL-24643 27 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LS2AU (INCLUDING VARIATION LS2AUS)《LS2AU型-20 ℃~+90 ℃电缆(包括变化型 LS2AUS)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 27 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LS2AU (INCLUDING VARIATION LS2AUS)《LS2AU型-20 ℃~+90 ℃电缆(包括变化型 LS2AUS)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/27F 1 October 2009 SUPERSEDING MIL-DTL-24643/27E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, 600 VOLTS, TYPE LS2AU (INCLUDING VARIATION LS2AUS) This specification is approved for use by all Departments and Agencies of the Department of Defen
2、se. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24643. This cable can be manufactured in two variations: LS2AU and LS2AUS (double overall shield). Construction, Non-Watertight First - Copper conductor, tin-coated, ASTM B286, Size
3、22 7strands. Second - Separator may be used at manufacturers option where required to provide free-stripping insulation. Third - Thermoset insulation. Minimum average wall thickness of 0.024 inch; telephone identification applied by Method 3. Fourth - Two conductors cabled together with a lay not gr
4、eater than 1 inches. Fifth - Forty two pairs cabled with a lay in accordance with 3.4.4 of MIL-DTL-24643. Fillers may be used as necessary to form a firm well-rounded assembly. Cabling sequence shall be consecutive, starting with no. 1. in the center outward. Sixth - An optional binder. Seventh - Br
5、aided shield of tin-coated copper. Minimum coverage of 85 percent. Construction, Variant for Type LS2AU Eighth - An optional binder. Ninth - Cross-linked polyolefin jacket. Minimum average wall thickness 0.060 inch. Construction, Variant for Type LS2AUS Eighth - Spirally wrapped 0.002-inch thick pol
6、yethylene (polyester film) separator tape with 25 percent minimum lap. Ninth - Braided shield of tin-coated copper. Minimum coverage of 85 percent. Tenth - An optional binder. Eleventh - Cross-linked polyolefin jacket. Minimum average wall thickness 0.060 inch. AMSC N/A FSC 6145 Provided by IHSNot f
7、or ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/27F TABLE I. Details. Overall diameter Military part no. M24643/27 Type and size Number of pairs Diameter over shielded core nom. (inch) min. (inch) max. (inch) -01UO LS2AU-40 40 1.089 1.320 1.370 -01UD LS2AU
8、S-40 40 1.120 1.380 1.430 REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) 17.71 Voltage withstand (volts, root mean square, min.) Conductor to conductor 2500 Overall shield to overall shield (Type LS2AUS only) 200 Insulation re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464327F2009CABLEELECTRICAL20DEGREECTO90DEGREEC600VOLTSTYPELS2AUINCLUDINGVARIATIONLS2AUSLS2AU

链接地址:http://www.mydoc123.com/p-978652.html