NAVY MIL-A-15344 J-1963 AMPLIFIER SYNCHRO SIGNAL《同步信号扩音器》.pdf
《NAVY MIL-A-15344 J-1963 AMPLIFIER SYNCHRO SIGNAL《同步信号扩音器》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-A-15344 J-1963 AMPLIFIER SYNCHRO SIGNAL《同步信号扩音器》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-A-LSLILIJ 57 9997906 0015bY2 T Type MIL-A-1 5344J(NAVY) Synchro units Synchro excitation frequency cycles per second (C.P.S.). 7 June 1963 SUPERSEDING Output 60 and 400 60 or 400 (not both) 60 and 400 MIL-A-1 5344H(NAVY) 14 November 1961 1 -speed 18CT6 or 23CT6 18CT6 or23CT6 18CT4 or 23CT4 MILiT
2、ARY SPECIFICATION AMPLIFIER, SYNCHRO SIGNAL All interested bureaus of the Department of the Navy have concurred in the use of this specification. 1. SCOPE 1.1 Scope.- This specification covers the requirements for synchro signal amplifiers for the purpose of providing a means of increasing the capac
3、ity of a synchro signai transmission system, converting from 60 to 400 cycle synchro signai transmission or from 400 to 600 cycle synchro signai transmission, and to isolate reflected oscillations from the input synchro signal bus. 1.2 Classification.- The synchro signal amplifier shall be of the ty
4、pes listed in table I, as specified (see 6.2). Table I - Synchro signal amplifier. Input I I 400 18-speed I36-speed 18CT6 or 23CT6 18CT4 or 23CT4 Output 31TX4 I 23TX4 I“ 123TX4 23TX4 I ,;id I - - - 6Gmd - 31TX4 31TX4 , or 23CT6 2. APPLICABLE DOCUMENTS 2.1 The following documents of the issue in effe
5、ct on date of invitation for bids or request for proposal, form a part of the specification to the extent specified herein. SPECIFICATIONS MILITARY MIL-1-983 ML-S-2335 - Synchros, 60 Cycle, 115 Volt. MIL-Q-9858 - Quality Control System Requirements. MIL-S-17087 - Servo Motors, 2 Phase, 400 Cycles. M
6、IL-E-17555 - Electronic and Electrical Equipment and Associated Repair Parts, Preparation MIL-S-20708 - Synchros, 60 and 400 Cycle, General Specification. - Interior Communication Equipment, Naval Shipboard; Basic Design Requirements for. for Delivery of. STANDARDS MILITARY MIL-STD-710 - Synchros, 6
7、0 and 400 Cycle. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-A- 15344J(NAVY) DRAWINGS BUREAU OF SHIPS 900O-S6202-73907 - Switchboard. indicator Light - 2, Lamp - SPF- Type B27A. (Copies of specifications, standards, drawings, and publications
8、 required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contract- ing officer. ) 2.2 Other publications. - The following document forms a part of this specification to the extent spec- ified herein. Unless otherwis
9、e indicated, the issue in effect on date of invitation for bids or request for proposal shall apply: OFFICIAL CLASSIFICATION COMMITTEE Uniform Freight Classification Rules. (Application for copies should be addressed to Officiai Classification Committee, 1 Park Avenue at 33rd St., New York 16, New Y
10、ork.) 3. REQUIREMENTS 3.1 Qualification. - The synchro signal amplifier equipment furnished under this specification shall be a product which has been tested, and passed the qualification tests specified herein, and has been listed on or approved for listing on the applicable qualified products list
11、. 3.2 Description. - The synchro signai amplifier shall consist of an amplifier, synchro control trans- formers (see table I); one alternating current (a.c.) two phase servo motor with necessary gear train for driving the synchro rotors, as specified in 3.7.2; and output synchro signal generators of
12、 appropriate size as specified (see 6.2) all assembled in a dripproof enclosure (see 3.6.1) with the necessary operating controls (see 3.6.4), indicator lights (see 3.7.4), alarm relays (see 3.7.5) and capacitors (see 3.7.6). 3.3 Operation. - The typical cycle of operation of the synchro signal ampl
13、ifier is as follows: A synchro signal, such as that obtained from a master gyrocompass is transmitted to the synchro control transformers (CTs) in the synchro amplifier. The signal received by the synchro control transformers is fed to the ampli- fier unit where it is intensified and used to actuate
14、 the follow-up motor which, through gearing, turns the synchro control transformer rotors until the induced voltages are reduced to a null, thereby stopping the follow-up action. At the same time the follow-up motor also drives, through gearing, the output synchro signal generator rotors. The output
15、 synchro signal generators actuate the remote network of synchro signal receivers which are then displaced the same angular amount as the input synchro signal. 3.4 General featur.es. - in addition to the requirements specified herein, the equipment shall be in accordance with MIL-1-983 except for th
16、e following paragraphs. (Whenever a requirement of MIL-1-983 conflicts with a requirement of this specification, the requirement of this specification shall govern): Universal mounting Stand mounting Panel mounting Bulkhead mounting Tumbling Gunblast Depth charge Dial illumination Repair parts (elec
17、tronic) Salt spray 3.5 Design.- The synchro signal amplifier shall be so designed that vibration, shock, or acceleration, which may be encountered in service aboard Naval ships, will not adversely affect the accuracy of the equipment, nor derange any part of the equipment beyond normal adjustment at
18、 sea. All parts except those necessary in electromagnetic circuits, ball bearings, shafts, thrust plates, and similar application where stremw hardness is essential shall be constructed of nonferrous, nonmagnetic materials. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted witho
19、ut license from IHS-,-,-MIL-A-1 5344J(NAW) 3.6 Mechanical features. - 3.6.1 Enclosure.- All parts required for the proper operation of the synchro signai amplifier shall be mounted in an enclosing case (degree of enclosure dripproof) designed for bulkhead, platform, and stack mounting (maximum of fo
20、ur units mounted one on top of another). Provision shall be made for the protection of gears from dust. Mounting and external wiring ofthe equipmentshall beaccompished, insofar as practical, without having to remove the amplifier or synchro unit from the enclosure and without having to expose the ge
21、ars to dust. A removable plate (a minimum of 4 inches by 8 inches by 1/8 inch) for the installation of stuffing tubes shall be provided on both sides of each enclosure. The enclosing case shall consist of an alumi- num angle or channel framework, suitably welded to form a structure of adequate stren
22、gth to support all sub- assemblies. A wrap-around or similar covering of aluminum shall be provided around the framework. inter- nal subassemblies shall not be supported by the aluminum covering. The case shall be sufficiently ventilated to meet the operating temperature requirements herein. Ventila
23、tion may be achieved by louvers in the ends and front cover, by screened openings in the bottom of the case and by umbrella type covered openings in the top. 3.6.2 Accessibility. - All units and subassemblies of the equipment shall be easily accessible for repair and adjustment. The access door to t
24、he amplifier shall be equipped with hinges and supporting straps or anchors and supporting chains so that it may act as a service platform for the amplifier internal assemblies. Protection of the internal subassemblies shall be provided in accordance with MIL-1-983. Supporting rods shall be furnishe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILA15344J1963AMPLIFIERSYNCHROSIGNAL 同步 信号 扩音器 PDF

链接地址:http://www.mydoc123.com/p-976829.html