NAVY A-A-50620-1994 ELECTRODE PH COMBINATION SEALED《密封化合物PH电极》.pdf
《NAVY A-A-50620-1994 ELECTRODE PH COMBINATION SEALED《密封化合物PH电极》.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-50620-1994 ELECTRODE PH COMBINATION SEALED《密封化合物PH电极》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、A-A-50620 9999974 0362303 b02 W A-A-5 062 O 28 January 1994 COMMERCIAL ITEM DESCRIPTION ELECTRODE, pH, COMBINATION SEALED The General Services Administration has authorized the use of this commercial item description as a replacement for DOD-E-24636 (SH) which is cancelled. Score: and reference elec
2、trode which is used in conjunction with a digital indicating pH meter to measure the pH of boiler water aboard naval ships. cable and connectors shall be compatible with the shipboard digital pH meter in use. This commercial item description covers a combination pH The combination electrode and its
3、connecting Salient characteristics: The electrode shall be permanently sealed and non- refillable. The outer body of the electrode shall consist of a rigid, impact-resistant opaque polymer material. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of us
4、e in improving this document should be addressed to: Commander, SEA 03R42, Naval Sea Systems Command, 2531 Jefferson Davis Hwy., Arlington, VA 22242-5160, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. Il D
5、ISTRIBUTION STATEMENT A. distribution is unlimited. AMSC N/A FSC 6630 II Approved for public release; Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50620 9999974 03623OLl 549 = A-A-5062 O The outer body of the electrode shall extend below the b
6、ottom of the glass sensing element in order to prevent accidental breakage of the glass and to enable the electrode to be used as a stirring rod in glass or plastic beakers. The electrode shall be shipped with the sensing and reference elements sealed in a liquid storage medium in order that the ele
7、ctrode be ready for use when received. length, with an outside diameter from 1 to 2 centimeters. 75 and 125 centimeters in length. with connectors for inputting to a digital pH meter. connectors to be provided shall consist of the following: Electrode dimensions shall be from 13 to 18 centimeters in
8、 The electrode electrical connecting cable shall be between Each electrode electrical connecting cable shall be provided The type of 1. One U.S. standard type connector for the sensing element. 2. One pin-tip connector for the reference element. In addition to the above connectors on the electrical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA506201994ELECTRODEPHCOMBINATIONSEALED 密封 化合物 PH 电极 PDF

链接地址:http://www.mydoc123.com/p-976317.html