NAVISTAR MPAPS F-32-2016 Sealant Coated Pipe Thread Fittings.pdf
《NAVISTAR MPAPS F-32-2016 Sealant Coated Pipe Thread Fittings.pdf》由会员分享,可在线阅读,更多相关《NAVISTAR MPAPS F-32-2016 Sealant Coated Pipe Thread Fittings.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2016 by Navistar, Inc. JUNE 2016 Page 1 of 6 NAVISTAR, INC. Material, Parts, and Process Specifications
2、(MPAPS) NUMBER: MPAPS F-32 Former Designation: CEMS-D31 (example) TITLE: Sealant Coated Pipe Thread Fittings CURRENT REV No.: 1606 DATE: JUNE 2016 WRITTEN/EDITED BY: W. Cook APPROVED BY: R. Goluch SUPERSEDES: Rev. 0604 APRIL 2006 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION
3、This specification may involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory
4、limits prior to use. 1.0 APPLICATION This specification applies to standard parts in sections MPAPS S-L and MPAPS S-M of Navistar Engineering Standard Parts specifications and other threaded pipe fittings. The pre-applied sealant aids in providing a leak-proof joint. 2.0 SCOPE The specification cove
5、rs Navistar requirements for externally threaded pipe fittings coated with a pre-applied sealant. The applicability of coated fittings to critical systems requiring special internal cleanliness should be thoroughly verified before use. 2.1 Restricted Chemical Substances Effective January 1, 2007, al
6、l product supplied to the requirements of this specification must comply with the requirements of the MPAPS B-50 specification. 3.0 REFERENCE DOCUMENTS Unless otherwise specified, the latest issue of all referenced standards shall apply. The following Specifications, Standards, and Regulations are r
7、eferenced in this specification. Quality System Standard ISO 9001 or TS-16949 NAVISTAR MPAPS B-1 CFR Title 29, Part 1910 NAVISTAR MPAPS B-50 NAVISTAR Manufacturing Std. MS-D-13 NAVISTAR MPAPS B-21 NAVISTAR Engineering Design Std A-16 NAVISTAR MPAPS B-32 NAVISTAR MPAPS S-L 1.101-GS/PL NAVISTAR MPAPS
8、S-L 61.101-GS/PL NAVISTAR MPAPS S-L 7.101-GS/PL NAVISTAR MPAPS S-L 9.101-GS/PL NAVISTAR MPAPS S-M 1.101-GS/PL NAVISTAR MPAPS S-M 2.101-GS/PL NAVISTAR MPAPS S-M 4.101-GS/PL NAVISTAR MPAPS S-M 5.101-GS/PL NUMBER: MPAPS F-32 TITLE: Sealant Coated Pipe Thread Fittings REVISION: 1606 This document is res
9、tricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2016 by Navistar, Inc. JUNE 2016 Page 2 of 6 4.0 REQUIREMENTS 4.1 Sealant 4.1.1 The purchaser will assign a color to each app
10、roved sealant to identify the manufacturer. 4.1.2 The sealant will not be corrosive to ferrous or non-ferrous metals. It will not have a degrading effect on the corrosion resistance of the basic finish of the fitting. 4.1.3 The sealant shall be capable of being used with both metal and plastic mater
11、ials. 4.1.4 The fully cured sealant shall be insoluble in water, diesel fuel, 50% mix of water and glycol, oil, automatic transmission fluid, power steering fluid and other chemicals commonly encountered in assembly and use of air brake system components. Exposure to these materials shall not affect
12、 the ability of the sealant to meet specified performance requirements. 4.2 Sealant Coated Fittings Coated fittings will meet the requirements of this specification in each of the four following conditions: (a) as received; (b) after at least 3 years storage in shipping containers at temperatures up
13、 to 35C; (c) after at least 120 hours exposure at -55 + 5C; (d) after at least 120 hours exposure at 120 + C. 4.2.1 Extent Of Coating Prior to sealant application, inspect the threads to be sure they are not damaged and do not contain slivers, burrs, dirt, or other contamination. The sealant will be
14、 uniformly applied around the circumference and along the length of the external threads of the fitting only. The sealant will be dry to the touch. The first one-half to two lead threads of the coated fitting will be substantially free of sealant. Substantially means a small quantity of sealant on t
15、he lead threads is permissible provided startability of the coated part into the mating pipe thread is not adversely affected. From the start location, a minimum of the next four threads shall be coated. The sealant shall be applied so that approximately 50% of the thread depth is filled with sealan
16、t. Sealant should not protrude beyond the major thread diameter. 4.2.2 Coating Weight. The total weight of sealant per fitting will conform to the limits shown. Nominal Size and Thread Pitch * Weight of Dry Sealant per Fitting (mg) * Brass Fittings Steel Fittings 1/16 27 11 27 - 1/8 27 15 30 20 40 1
17、/4 18 30 60 40 80 3/8 18 60 100 80 120 1/2 14 120 200 140 240 3/4 14 140 250 200 280 1 11-1/2 200 340 240 380 1-1/4 11-1/2 240 380 280 420 * Dryseal American Standard Taper Pipe Thread (NPTF). * Applicable only to Dryseal American Standard Taper Pipe Thread (NPTF) fittings. Limits for other types of
18、 fittings, such as NPT SAE Short, will be agreed upon by the purchaser and supplier and then specified on engineering drawings and purchase orders. NUMBER: MPAPS F-32 TITLE: Sealant Coated Pipe Thread Fittings REVISION: 1606 This document is restricted and may not be sent outside Navistar, Inc. or r
19、eproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2016 by Navistar, Inc. JUNE 2016 Page 3 of 6 4.2.3 Leakage. Coated fittings assembled for testing will meet the limits for leakage shown below. Test Leakage, cm3/minute max., for N
20、ominal Fitting Sizes * 1/16-27 1/8-27 1/4-18 3/8-18 1/2-14 3/4-14 1-11-1/2 1-1/4-11-1/2 Initial Installation 0 0 0 0 0 0 0 0 Repositioning * 0.5 1.0 2.0 3.0 5.0 6.0 8.0 10.0 Reuse * 0 0 0 0 0 0 0 0 Fluid Immersion, all Specified Test Fluids 0 0 0 0 0 0 0 0 * Dryseal American Standard Taper Pipe Thre
21、ad (NPTF). * Repositioning (back out) during assembly of pipe thread joints is NOT recommended. Detailed assembly instructions are defined in International Engineering Functional Instructions or other informational documents. This repositioning test is only a means to determine if fittings have been
22、 properly coated. * The reuse test requirement is NOT applicable to coated fittings that have been in service. Specific recommendations and/or instructions for reuse of coated fittings in service will be established by International Engineering where necessary. 5.0 QUALITY All product supplied shall
23、 be clean and free from dirt, oils, sharp edges, or defects harmful to product performance. 6.0 QUALIFICATION Engineering qualification of sources by Materials Engineering is required in advance of production shipments. Samples shall be accompanied by test data certifying that all requirements of th
24、e specification have been met. 6.1 Quality Control Plan A Quality Control Plan for products supplied to the requirements of this specification will be established by mutual agreement between NAVISTAR and the supplier. Unless specific exception is noted, the following characteristics, where applicabl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVISTARMPAPSF322016SEALANTCOATEDPIPETHREADFITTINGSPDF

链接地址:http://www.mydoc123.com/p-962956.html