《NA to BS EN 1993-1-9-2005 UK National Annex to nEurocode 3 Design of nsteel structures – nPart 1-9 Fatigue《欧洲法规3的英国国家附录 钢结构的设计 疲劳》.pdf》由会员分享,可在线阅读,更多相关《NA to BS EN 1993-1-9-2005 UK National Annex to nEurocode 3 Design of nsteel structures – nPart 1-9 Fatigue《欧洲法规3的英国国家附录 钢结构的设计 疲劳》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、NA to BS EN 1993-1-9:2005UK National Annex to Eurocode 3: Design of steel structures Part 1-9: FatigueICS 91.010.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWNATIONAL ANNEXLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 30/07/2008 08:14, Uncontrolled Copy, (c) BSIPu
2、blishing and copyright informationThe BSI copyright notice displayed in this document indicates when the document was last issued. BSI 2008ISBN 978 0 580 54971 7The following BSI references relate to the work on this standard:Committee reference B/525/10 and B/525/31Draft for comment 07/30128138 DCP
3、ublication historyFirst published May 2008Amendments/corrigenda issued since publicationDate Text affectedNA to BS EN 1993-1-9:2005Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 30/07/2008 08:14, Uncontrolled Copy, (c) BSI BSI 2008 iNA to BS EN 1993-1-9:2005ContentsIntroduction 1NA.1 Scope 1
4、NA.2 Nationally Determined Parameters 1NA.3 References to non-contradictory complementary information 5Bibliography 6List of tablesTable NA.1 Minimum required fatigue strength 2Table NA.2 Recommended *Fffor safe life design 3Summary of pagesThis document comprises a front cover, an inside front cove
5、r, pages i and ii, pages 1 to 6, an inside back cover and a back cover.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 30/07/2008 08:14, Uncontrolled Copy, (c) BSINA to BS EN 1993-1-9:2005ii BSI 2008 This page deliberately left blankLicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 30/07
6、/2008 08:14, Uncontrolled Copy, (c) BSI BSI 2008 1NA to BS EN 1993-1-9:2005National Annex (informative) to BS EN 1993-1-9:2005, Eurocode 3 Design of steel structures Part 1-9: FatigueIntroductionThis National Annex has been prepared by BSI Subcommittee B/525/10, Bridges, in consultation with B/525/3
7、1, Structural use of steel. In the UK it is to be used in conjunction with BS EN 1993-1-9:2005.NA.1 ScopeThis National Annex gives:a) the UK decisions for the Nationally Determined Parameters described in the following clauses and subclauses of BS EN 1993-1-9:2005: 1.1(2)Clause 2(2)Clause 2(4)Clause
8、 3(2)Clause 3(7)Clause 5(2) 6.1(1) 6.2(2) 7.1(3) 7.1(5)Clause 8(4)b) references to non-contradictory complementary information.NA.2 Nationally Determined ParametersNA.2.1 Material and execution tolerances and information on inspection requirements for fabrication BS EN 1993-1-9:2005, 1.1(2)NA.2.1.1
9、Material and execution tolerancesUntil such time as BS EN 1090-2 is published, the rules are applicable to structures where execution conforms to either BS 5400-6:1999 for bridges or BS 5950-2:2001 for buildings. Note that, where BS 5400-6:1999 makes reference to minimum class requirements D, E and
10、F, Unspecified, these may be taken to refer to a minimum requirement for the value of %c= 91 N/mm2, 80 N/mm2, 63 N/mm2and 56 N/mm2respectively. For additional guidance see NA.3.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 30/07/2008 08:14, Uncontrolled Copy, (c) BSINA to BS EN 1993-1-9:200
11、52 BSI 2008NA.2.1.2 Information on inspection requirements for fabricationFor the safe life method of assessment, special inspection and testing requirements for welds, cut edges and plain surfaces should be provided on drawings for all applications where the minimum required fatigue strength exceed
12、s the relevant value of cin Table NA.1.For additional guidance see NA.3.NA.2.2 Fatigue loading models BS EN 1993-1-9:2005, Clause 2(2)NA.2.2.1 Sources of fatigue loadingAll sources of fluctuating stress in the structure should be identified and should be obtained from the relevant parts of BS EN 199
13、1. For fatigue loading not covered in BS EN 1991 the following should receive particular attention:a) superimposed moving loads, including vibrations from machinery in stationary structures;b) environmental loads such as wind, waves, etc.;c) acceleration forces in moving structures;d) temperature ch
14、anges.Where no published data for live loading exist, the partial safety factors for fatigue load intensity for safe life design should take into account the degree of confidence in the prediction of the design load spectrum from the available data. Recommended values of Ffare given in Table NA.2.Ta
15、ble NA.1 Minimum required fatigue strengthDetail type according to BS EN 1993-1-9 Fatigue strength levels, c Table Detail numbers N/mm28.1 1, 2, 3, 4 1258.2 1, 2, 3, 4, 5, 6, 7, 10, 11 908.31, 2, 4, 5, 7, 19 808, 10 713, 6 638.4 4 808.8 5 80NOTE Minimum required fatigue strength is the value of c th
16、at would just achieve compliance with BS EN 1993-1-9:2005, Clause 8.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 30/07/2008 08:14, Uncontrolled Copy, (c) BSI BSI 2008 3NA to BS EN 1993-1-9:2005Reference to guidance on determination of specific fatigue loading models is given in NA.3.NA.2.3
17、 Determination of fatigue strength from tests BS EN 1993-1-9:2005, Clause 2(4)Reference to guidance on determination of specific fatigue strength data from tests is given in NA.3.NA.2.4 Provisions for in-service inspection programmes BS EN 1993-1-9:2005, Clause 3(2)In the event that the damage toler
18、ant assessment method is to be used, the following provisions apply.a) The designer should be satisfied that the Maintaining Authority for the structure is aware of the practical requirements and the likely costs of provision of access, the inspection itself, possible repair and temporary loss of se
19、rvice, prior to approval being given.b) Any potential fatigue crack initiation sites should be on or close to a surface which will be readily accessible in service.c) The method or methods of inspection should be specified for each potential fatigue initiation site. Inspection for fatigue cracking r
20、equires more sophisticated techniques than are used for normal principal inspections.d) The minimum size of detectable fatigue crack should be specified for each initiation site, taking into account the capability of the methods in c).e) The maximum tolerable size of fatigue crack (using fracture me
21、chanics) for fracture under ULS loading should be calculated.f) The time taken for the fatigue crack to grow from the minimum detectable size in d) to the fracture tolerable size in e) should be calculated by fracture mechanics using upper bound crack growth data and the upper bound fatigue loading.
22、 g) The maximum interval between inspections should be not more than half the time calculated in f). This may be less than the interval between principal inspections.h) Guidance should be given on any requirements for taking the structure out of service or increasing the inspection frequency in the
23、event that cracks are detected.Table NA.2 Recommended Fffor safe life designNumber of standard deviations on load intensityValue of Ff0 standard deviations A)+2 standard deviations A)01,5 1,4+1 1,3 1,2+2 1,1 1,0A)Number of standard deviations on number of cycles.Licensed Copy: Wang Bin, ISO/EXCHANGE
24、 CHINA STANDARDS, 30/07/2008 08:14, Uncontrolled Copy, (c) BSINA to BS EN 1993-1-9:20054 BSI 2008i) Viable schemes should be drawn up for repair, strengthening or replacement of the member where fatigue cracks have been detected.j) A maintenance manual should be provided to the maintaining authority
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NATOBSEN1993192005UKNATIONALANNEXTONEUROCODE3DESIGNOFNSTEELSTRUCTURES NPART19FATIGUE 欧洲 法规 英国 国家 附录 钢结构

链接地址:http://www.mydoc123.com/p-835673.html