MSFC NASA MWI 8715 11 REV I-2008 FIRE SAFETY PROGRAM《防火程序》.pdf
《MSFC NASA MWI 8715 11 REV I-2008 FIRE SAFETY PROGRAM《防火程序》.pdf》由会员分享,可在线阅读,更多相关《MSFC NASA MWI 8715 11 REV I-2008 FIRE SAFETY PROGRAM《防火程序》.pdf(56页珍藏版)》请在麦多课文档分享上搜索。
1、CHECK THE MASTER LIST at https:/repository.msfc.nasa.gov/directives/directives.htm VERIFY THAT THIS IS THE CORRECT VERSION BEFORE USE MWI 8715.11 REVISION I EFFECTIVE DATE: October 1, 2008 EXPIRATION DATE: October 1, 2013 MARSHALL WORK INSTRUCTION QD01 FIRE SAFETY PROGRAM Provided by IHSNot for Resa
2、leNo reproduction or networking permitted without license from IHS-,-,-Marshall Work Instruction QD01 Fire Safety Program MWI 8715.11 Revision: I Date: October 1, 2008 Page 2 of 56 CHECK THE MASTER LIST at https:/repository.msfc.nasa.gov/directives/directives.htm VERIFY THAT THIS IS THE CORRECT VERS
3、ION BEFORE USE DOCUMENT HISTORY LOG Status (Baseline/ Revision/ Canceled) Document Revision Effective Date Description Baseline 2/2/00 Revision A 3/28/01 Document renumbered in accordance with MPG 1410.2; changed “3.2” to “NSS-1740.12, NASA Safety Standard for Explosives, Propellants, and Pyrotechni
4、cs”; changed title of “3.7” to “Marshall Safety, Health, and Environmental (SHE) Program”; deleted “b” in section 4; added definition for “Impairment Plan”; changed 5.2 to read “precautions for operation involving open flames or producing heat and/or sparks. This includes, but not limited to: Brazin
5、g, Cutting, Grinding, Soldering with a torch, Thawing Pipe, Torch-Applied Roofing and Cad Welding”; revised 6.1.4 to read “building manager, Industrial Safety Department, building occupantsreturn to normal. The building manager is responsible for notifying the building occupants of the fire protecti
6、on system outage”; revised 6.1.5 to read “are taken. The Facilities Engineering Department is responsible for maintaining an outage log documenting impairment plan requirement”; deleted “and fire hose stations” from 6.1.6; revised 6.1.6 to read “spreadsheet will be maintained by the building manager
7、 and/or building manager assistant to document the type and location of each fire extinguisher in their area or responsibility”; revised 6.2.2 to read “markings shall be placedwith requirements of NSS-1740.12”; revised 6.5.1 to read “Housekeeping, cleanliness, and means of egress are maintainedof NF
8、PA 101, Chapter 7, 29 CFR 1910.22, and MPG 8715.1”; revised 6.5.4 to read “self-closing lids meeting NFPA 30A requirements are provided”; revised 6.6.1 to read “makers, portable heaters, urns, hot plates, ovens, microwave ovens, grills, and similar heat-producing devices”; revised 6.6.2 to read “or
9、Assistant will issue a permit, MSFC Form 3798. The user is responsible for posting the permit at eachPermit approval is based”; revised 6.f.(3) to read “The user shall operate the portable”; revised 6.6.4 to read “The user is responsible for shutting off portableunattended and at the end of the work
10、day”; added 6.6.5 and NOTE 1”; revised 6.6.6 to read “hours or when no one is working in the area”; added 6.6.7 through 6.6.9; deleted 6.f.(8); added “and combustible”“reference h(1)” to 6.7.4; added “and combustible”; revised 6.8.3 to read “heaters (Kerosene) are not used unless ALL the following r
11、equirements are met and with S added 6.8.3.1 through 6.8.3.8; revised 6.13.2 to read “from any occupied building”; revised paragraph 9.1 to read “Log (Impairment Plan)”; revised 9.4 to read “will be maintained by the building manager or assistant building manager for the length of time he or she is
12、responsible for checking the fire extinguishers, then destroy or maintain for historical purposes”; added 9.6 and added “Employees who are expected/ required to use portable fire extinguishers will be trained annually in the general principles of fire extinguisher use and the hazards involved with i
13、ncipient stage fire fighting per 29 CFR 1910.157 (g). The hands-on portable fire extinguisher training offer by the Redstone Fire Department will meet this requirement at MSFC. Revision B 8/27/02 Purpose changed to fire safety, 3.3 changed to NASA-STD-8719.12, 3.6 added CGP P-1, 6.1.6 added appendix
14、 C, 6.6.6.1 reworded, 6.1.7 added mechanical/equipment rooms, 6.1.7.2 added mechanical/equipment room, 6.1.7.3 added hot work permit, 6.3.1 deleted exit, 6.3.2 added emergency/evacuation, 6.4.1 added Natural Christmas tree, 6.5.2 added required egress, 6.6.1 added electrical grills, 6.6.2 added port
15、able appliances, 6.6.4.2 added portable appliance, 6.6.5 added portable Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Marshall Work Instruction QD01 Fire Safety Program MWI 8715.11 Revision: I Date: October 1, 2008 Page 3 of 56 CHECK THE MASTER LIS
16、T at https:/repository.msfc.nasa.gov/directives/directives.htm VERIFY THAT THIS IS THE CORRECT VERSION BEFORE USE appliance, 6.6.6.1 added no more than, 6.6.7 added Portable, 6.6.8 added portable, 6.6.9 added portable, 6.7 added portable charcoal or propane grills, 6.8 added MSFC Form 1155, 6.8.3.1
17、added MSFC Form 1155, 6.8.4 added or, 6.9.3 added areas that have cloth, 6.9.3.1 added steel waste, 6.9.4 added kerosene and oil-fired heaters, 6.9.4.1 added all heaters, 6.9.4.2, 6.9.4.3 added and built-in, 6.9.4.7 added will be required, 6.9.4.8 added required in the, 6.9.4.9 added heater will onl
18、y, 6.9.4.10 added In no case, 6.10.3 added in accordance with, 6.10.3 added bottles (approx 14, 6.13 added specifically designed, 9.4 added or the Facilities, 10.1 added The hands-on, 10.2 added Additional safety awareness, added Appendix C Revision C 5/6/2004 Minor word changes throughout document,
19、 added Definition, 6.4 expanded Fire Emergency Procedure section, reworded 6.5.2 required for artificial holiday trees, added 6.6 candles, added 6.8.2.1, reworded 6.8.4, expanded 6.8.5 a material that does not meet the definition of noncombustible or limited-combustible. 5.6 Commodity. Combinations
20、of products, packing material, and container upon which the commodity classification is based. 5.7 Compatible Material. A material that, when in contact with an oxidizer will not react with the oxidizer or promote or initiate its decomposition. Provided by IHSNot for ResaleNo reproduction or network
21、ing permitted without license from IHS-,-,-Marshall Work Instruction QD01 Fire Safety Program MWI 8715.11 Revision: I Date: October 1, 2008 Page 8 of 56 CHECK THE MASTER LIST at https:/repository.msfc.nasa.gov/directives/directives.htm VERIFY THAT THIS IS THE CORRECT VERSION BEFORE USE 5.8 Control A
22、rea (as it applies to flammable and combustible liquid storage and use). A building or portion of a building within which flammable and combustible liquids are allowed to be stored, dispensed, and used or handled in quantities that do not exceed the maximum allowable quantity shown in Chapter 11. 5.
23、9 Fire Retardant Container. A nationally-recognized testing laboratory container of normally not more than 5.3 gallon (20 liter) capacity, having a self-closing lid and spout cover and so designed to safely relieve internal pressure when subjected to fire exposure. 5.10 Flammable Liquid. Any liquid
24、that has a closed-cup flash point below 100 degrees F. 5.11 Flame Spread Index. A comparative measure, expressed as a dimensionless number, derived from visual measurements of the spread of flame versus time for a material tested. 5.12 Flash Point. The minimum temperature of a liquid at which suffic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- MSFCNASAMWI871511REVI2008FIRESAFETYPROGRAM 防火 程序 PDF

链接地址:http://www.mydoc123.com/p-822916.html