1、 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 by Navistar, Inc. AUGUST 2009 Page 1 of 8 NAVISTAR, INC. CEMS (CORPORATE ENGINEERING MATERIAL SPECI
2、FICATION) NUMBER: CEMS GT-13 TITLE: Panel Preparation CURRENT ISSUE DATE: August 2009 WRITTEN/REVIEWED BY: Materials Engineering APPROVED BY: Materials Engineering SUPERSEDES ISSUE OF: August 2001 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specification may involve ha
3、zardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to use. Change Notic
4、e: Replaced “International Truck and Engine Corporation” with “Navistar, Inc.” per corporate directive. 1.0 SCOPE This test procedure covers the specific methods for paint panel preparation for each of the grades of paint described in CEMS G-5, Parts II, III, IV, V, VI, and VIII. All test designatio
5、ns refer to the latest issue unless otherwise stated. CONTENTS Grades Method Page -17, -17HS, -19, - 19HS A 1-2 -32, -32HS, -32W, -32HS/Ur, -62, -81W, -81HS, -82W, -83W B 2-3 -29, -29T, -29HS, -29THS C 3 -33 D 3-4 -55, -55W E 4 -41, -43, -43W F 4 -50, -53, -53A G 4-5 -52, -52HS, -52W H 5-6 -54 I 6-7
6、 -61 J 7 -56 K 7-8 -18 L 8 2.0 TEST PANEL REQUIREMENTS The vendor, submitting a product for qualification, should use an appropriate number of panels to perform all required tests. Additional factors affecting the number of test panels include the types of substrates or coatings the product will be
7、applied to and any subsequent coatings that may be applied over the vendors product. Possible substrates include cold rolled steel, galvanized steel, cast iron, aluminum, and various plastics including SMC. For additional information, contact the TDTC, Paint Laboratory, Materials Engineering, 2911 M
8、eyer Road, Fort Wayne, IN 46801-1109. 2.1 METHOD A 2.1.1 Obtain panels pretreated with zinc phosphate and preprimed with a Grade -56 E-coat representative of current production. 2.1.2 Using the appropriate solvent(s), dilute and activate if necessary one liter of paint prepared according to the step
9、s outlined in CEMS G-5, Part I, Section B, “Sampling Procedure” to a viscosity as follows: Copyright Navistar International Corporation Provided by IHS under license with INTERNNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NUMBER: CEMS GT-13 TITLE Panel Preparati
10、on CURRENT ISSUE DATE: August 2009 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 by Navistar, Inc. AUGUST 2009 Page 2 of 8 2.1.2.1 Grades -17 and
11、-17HS: Dilute the paint to 18+ 1 seconds using a No.4 Ford Cup per ASTM D1200, then activate with isocyanate (6 parts paint:1 part isocyanate, unless otherwise specified by the manufacturer.) 2.1.2.2 Grade -19: Dilute the paint to 18+ 1 seconds using a NO. 4 Ford cup. 2.1.2.3 Grade -19HS: Dilute the
12、 paint to 25+ 1 seconds using a No. 4 Ford Cup. 2.1.3 Spray the panels with adjusted paint from step (2.1.2) at 21 to 27C (70 to 80F) using a siphon or pressure gun set at 414 to 483 kPa (60 to 70 psi). Apply a first coat of enamel, flash dry for three minutes, then apply a second coat of enamel. Fo
13、r paints containing metallic pigments, a thin third coat is recommended. 2.1.4 All panels shall be uniformly coated and free from sags, runs, wrinkles, or other irregularities. 2.1.5 Dry the panels in a vertical position for five minutes in still air at 21 to 27C (70 to 80F), then place in a recircu
14、lating oven as follows. 2.1.5.1 Grades -17 and -17HS: Bake the panels at 94+ 3C (200+ 5F) for thirty minutes. Remove and cool to 21 to 27C (70 to 80F). 2.1.5.2 Grades -19 and -19HS: Bake the panels at 121+ 3C (250+ 5F) for thirty minutes. Remove and cool to 21 to 27C (70 to 80F). 2.1.6 Determine the
15、 dry film thickness of the enamel applied to each panel by measuring the dry film thickness of the enamel and primer and subtracting from this the dry film thickness of the primer only. Panels suitable for use in testing the properties of these grades of enamel will exhibit a dry film thickness of t
16、he enamel topcoat of 43 to 59 m (1.7 to 2.3 mils). 2.2 METHOD B 2.2.1 Clean the panels by wiping with industrial grade xylene per ASTM D364. 2.2.2 For Bonderite CD-10 or Bonderite 958 zinc phosphated steel panels only, age the cleaned panels for one hour in a recirculating oven 113 + 9C (235 + 15F)
17、and then cool to 21 to 27C (70 to 80F). 2.2.3 Protect all panels from rust, oil, fingerprints, or other forms of surface contamination. 2.2.4 Using the appropriate solvents, dilute one liter of paint which has been prepared according to the steps outlined in CEMS G-5, Part I, Section B, under “Sampl
18、ing Procedure”, to a viscosity as follows: 2.2.4.1 Grade -62: Dilute the paint to 24 + 1 second using a No. 4 Ford cup per ASTM D1200, per the paint manufacturers recommendations. 2.2.4.2 Exceptions: Grades -32, -32HS and -81HS may be supplied in the spray as received condition; if so, proceed immed
19、iately to (2.2.5). 2.2.5 For paints containing metallic pigments, spray the panels with adjusted paint from step (2.2.4) at 21 to 27C (70 to 80F) using a siphon or pressure gun set at 552 kPa (80 psi). For paints not containing metallic pigments, spray the panels with adjusted paint from step (2.2.4
20、) at 21 to 27C (70 to 80F) using a siphon or pressure gun set at 414 to 483 kPa (60 to 70 psi). As an option, paints without metallic pigments may be applied to all panels except those to be used for testing initial gloss per Test Method GT-6B or color per Federal Standard 141a, Method 4250, by dipp
21、ing or with a doctor blade. The panels to be used to determine conformance to the initial gloss or color requirements of this grade of paint will always be sprayed. On all referee questions, a sprayed panel will be used. 2.2.6 All panels will be uniformly coated and free from sags, runs, wrinkles, o
22、r other irregularities. 2.2.7 Dry the panels in still air at 21 to 27C (70 to 80F) or as shown in table, in a vertical position for the time shown below: Copyright Navistar International Corporation Provided by IHS under license with INTERNNot for ResaleNo reproduction or networking permitted withou
23、t license from IHS-,-,-NUMBER: CEMS GT-13 TITLE Panel Preparation CURRENT ISSUE DATE: August 2009 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 by
24、 Navistar, Inc. AUGUST 2009 Page 3 of 8 3 Minutes 180 F Panel Temp. 15 Minutes 30 Minutes 6 Hours Grade -32 Grade -32W Grade -32HS Grade -81HS Grade 81W Grade 82W Grade 83W Grade 62 Grade 32HS/Ur 2.2.8 Measure the dry film thickness of the paint applied to each of the panels (after the panel is dry)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- INTERNCEMSGT132009PANELPREPARATION 面板 PDF