FORD FLTM BV 119-01-2000 ELECTROCOAT COMPATIBILITY TEST (Replaces FLTM BV 019-01)《电涂层相容性试验 替代FLTM BV 019-01》.pdf
《FORD FLTM BV 119-01-2000 ELECTROCOAT COMPATIBILITY TEST (Replaces FLTM BV 019-01)《电涂层相容性试验 替代FLTM BV 019-01》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BV 119-01-2000 ELECTROCOAT COMPATIBILITY TEST (Replaces FLTM BV 019-01)《电涂层相容性试验 替代FLTM BV 019-01》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BV 119-01 Date Action Revisions 2000 12 11 Revised Editorial no technical change A. Cockman 1992 05 05 Printed copies are uncontrolled Page 1 of 3 Copyright 2000, Ford Global Technologies, Inc. ELECTROCOAT COMPATIBILITY TEST Application This method defines the process fo
2、r determining the compatibility of various manufacturing processing materials (i.e., drawing oils, blanking oils, anti-rust oils, etc.), and manufacturing materials (i.e., adhesives, sealants, etc.) with electrocoat primers. Apparatus Required Power Source A direct current power source which can be
3、adjusted between 0 - 1000 volts DC and 0 - 10 amp. Coating Tank A 18.9 litre electrically insulated metal container approximately 280 mm I.D. and 330 mm high. As an alternative, a 3.8 litre electrically insulated metal container approximately 165 mm I.D. and 190 mm high may be used. Laboratory Stirr
4、er 0 to 700 rpm, using a 460 mm long shaft with a 50 mm diameter square end single blade impeller. Oven A mechanical convection oven capable of obtaining 190 C metal temperature on CRLC steel 0.89 mm within 8 - 10 minutes (Blue M Model No. POM166A-6X or equivalent). Materials Required Steel Panels S
5、teel panels required for this test are 100 x 300 x 0.89 mm. They shall be phosphate coated to meet the requirements of Engineering Material Specification ESB-M3P1-A. (Panels which have not been newly phosphated should be dried at 120 C for 6 minutes prior to test material application to remove absor
6、bed moisture.) An alternative size panel 75 x 200 x 0.89 mm may be used. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested un
7、der the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BV 119-01 Page 2 of 3 Copyright 2000, Ford Global Technologies, Inc. Procedure A. Material Applied to Substrate Before Electrocoating 1. Processing of Control Panels to Verify Suitability of Bath Using phosphated steel p
8、anels and a sample of each electrocoat primer as specified in the Engineering Material Specification, prepare control panels per FLTM BI 120-01. There should be sufficient primer used to bring the level of the primer approximately 50 mm from the top of the coating tank. Electrocoat the panels and ba
9、ke at conditions necessary to meet the “moderate“ film build and minimum bake schedule electrocoat specification requirements. Examine panels for film smoothness and lack of cratering. If film is irregular or cratered, bath is not suitable for compatibility testing. 2. Preparation and Treatment of T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV119012000ELECTROCOATCOMPATIBILITYTESTREPLACESFLTMBV01901 涂层 相容性 试验 替代 FLTMBV01901PDF

链接地址:http://www.mydoc123.com/p-747625.html