FORD FLTM AS 001-1-2001 TEST FOR DICYCLOHEXYLAMMONIUM NITRITE.pdf
《FORD FLTM AS 001-1-2001 TEST FOR DICYCLOHEXYLAMMONIUM NITRITE.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM AS 001-1-2001 TEST FOR DICYCLOHEXYLAMMONIUM NITRITE.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD AS 001-01 Date Action Revisions 2001 01 31 Revised Editorial no technical change A. Cockman 2000 04 25 Editorial no technical change A. Cockman 1992 05 01 Printed copies are uncontrolled Page 1 of 3 Copyright 2001, Ford Global Technologies, Inc. TEST FOR DICYCLOHEXYLAMMO
2、NIUM NITRITE Application This procedure is used to determine the amount of volatile corrosion inhibitor in treated papers. It should only be used for papers which have dicyclohexylammonium nitrite as the single corrosion inhibitor in the paper. Apparatus Required Photelometer or Spectrophotometer Th
3、e Photelometer or Spectrophotometer used in this test shall have a transmission band at 540 Mu with maximum band width of 60 Mu. Solutions Required Hydrochloric Acid (1:1) Dilute 25 mL of HCl Sp. Gr. 1.18 with an equal volume of distilled water. Sulfanilamide Solution - 0.2 % Weigh 1.0 g of the reag
4、ent, Eastman No. 4378, dissolve in distilled water and dilute to 500 mL. Store in a dark bottle and renew the solution every two months. N-1 Naphthylethylenediamine Dihydrochloride - 0.1 % Solution Weigh 1.0 g of the reagent, Eastman No. 4835, dissolve in distilled water and dilute to 1000 mL. Store
5、 in a dark bottle and renew the solution every two months. Standard Sodium Nitrite Solution Dissolve 1.0000 g of CP NaNO2 in distilled water and dilute to 1000 mL in a volumetric flask and mix thoroughly. Dilute 10 mL of this solution to 1000 mL with distilled water and mix thoroughly. Each mL of th
6、e resulting dilute standard solution contains 10 micrograms (0.010 milligrams) of sodium nitrite equivalent to 33 micrograms of dicyclohexylammonium nitrite. This solution should be stored in a dark bottle and made fresh every two months. FORD LABORATORY TEST METHOD AS 001-01 Page 2 of 3 Copyright 2
7、001, Ford Global Technologies, Inc. Standardization Prepare a curve on graph paper plotting the Photelometer reading vs. dicyclohexylammonium nitrite as follows: Introduce 1, 2, 3, 4 and 5 mL of the dilute sodium nitrite solution into separate 50 mL volumetric flasks and proceed with development of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMAS00112001TESTFORDICYCLOHEXYLAMMONIUMNITRITEPDF

链接地址:http://www.mydoc123.com/p-746840.html