EN 60896-11-2003 en Stationary lead-acid batteries Part 11 Vented types - General requirements and methods of tests《固定式铅酸蓄电池 第11部分 开孔透气型 一般要求和试验方法 IEC 60896-11-2002 替代 EN 60896-1-1.pdf
《EN 60896-11-2003 en Stationary lead-acid batteries Part 11 Vented types - General requirements and methods of tests《固定式铅酸蓄电池 第11部分 开孔透气型 一般要求和试验方法 IEC 60896-11-2002 替代 EN 60896-1-1.pdf》由会员分享,可在线阅读,更多相关《EN 60896-11-2003 en Stationary lead-acid batteries Part 11 Vented types - General requirements and methods of tests《固定式铅酸蓄电池 第11部分 开孔透气型 一般要求和试验方法 IEC 60896-11-2002 替代 EN 60896-1-1.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests The European Standard EN 60896-11:2003 has the status of a British Standard ICs 29.220.20 BS EN 60896-1 1:2003 British st3 nda rd tg NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITT
2、ED BY COPYRIGHT LAW BS EN 60896-11:2003 National foreword This British Standard is the official English language version of EN 60896-11:2003. It is identical with IEC 60896-11:2002. It supersedes BS EN 60896-1:1992 which will be withdrawn on 2005-12-01. The UK participation in its preparation was en
3、trusted to Technical Committee PEL/21, Secondary cells and batteries, which has the responsibility to: - - aid enquirers to understand the text; present to the responsible internationaUEuropean committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed
4、; monitor related international and European developments and promulgate them in the UK. - A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in t
5、his document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online This publication does not purport to include all the necessary provisions of a co
6、ntract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. This British Standard was published under the authority of the Standards Policy and Stratew Committee on Summary Of pages This document comprises a
7、 front cover, an inside front cover, the EN title page, 12 March 2003 pages 2 to 20, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. IDate I Comments O BSI 12 March 2003
8、 ISBN O 580 41365 9 EUROPEAN STANDARD EN 6089641 NORME EUROPENNE EUROPISCHE NORM January 2003 ICs 29.220.20 Supersedes EN 60896-1:1991 + A2:1992 English version Stationary lead-acid batteries Part 11 : Vented types - General requirements and methods of tests (I EC 60896-1 1 12002) Batteries stationn
9、aires au plomb Partie 11 : Batteries au plomb du type ouvert - Prescriptions gnrales et mthodes dessai (CE1 60896-1 112002) Ortsfeste Blei-Akkumulatoren Teil 1 1 : Geschlossene Batterien - Allgemeine Anforderungen und P rfve ra h ren (IEC 60896-1 1 12002) This European Standard was approved by CENEL
10、EC on 2002-1 2-01. CENELEC members are bound to comply with the CENICENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standar
11、ds may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notifi
12、ed to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,
13、 Slovakia, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels O 2003 CENELEC - All r
14、ights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60896-1 1:2003 E Page 2 EN 60896-112003 Foreword The text of document 21/572/FDIS, future edition 1 of IEC60896-11, prepared by IECTC21, Secondary cells and batteries, was submitted to the IEC-CENE
15、LEC parallel vote and was approved by CENELEC as EN 60896-1 1 on 2002-12-01. This European Standard supersedes EN 60896-1 :I991 + A2:1992. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endo
16、rsement - latest date by which the national standards conflicting with the EN have to be withdrawn Annexes designated “normative“ are part of the body of the standard. Annexes designated “informative“ are given for information only. In this standard, annex ZA is normative and annex A is informative.
17、 Annex ZA has been added by CENELEC. Endorsement notice (dop) 2003-09-01 (dow) 2005-12-01 The text of the International Standard IEC 60896-1 1 :2002 was approved by CENELEC as a European Standard without any modification. Page 3 EN 60896-112003 CONTENTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1
18、9 20 21 22 23 24 Scope and object 4 Normative references . 4 Definitions 5 Mechanical strength . 5 Electrolyte levels 5 Electrolyte reserve 5 Capacity . 6 Suitability for floating battery operation . 6 Endurance 7 Charge retention . 7 Short-circuit current and internal resistance 8 Accuracy of measu
19、ring instruments 8 Preparation of cells and batteries for testing . 9 Capacity test 9 Test of suitability for floating battery operation . 11 Endurance in discharge-charge cycles 12 Endurance in overcharge 12 Charge retention test 13 Short-circuit current and internal resistance determination 13 Tes
20、t sequence 15 Cell and battery markings . 15 Information to be included on the cell or monobloc package . 16 Recommended information for the battery room . 16 Marking of polarity 16 Annex A (informative) Recommended tests 17 Annex ZA (normative) Normative references to international publications wit
21、h their corresponding European publication . 20 Figure 1 . Discharge characteristic U =AI) . 14 Figure 2 . Typical test circuit 15 Table 1 . Test sequence recommended for type tests . 15 Table A.l . Recommended use of tests for stationary battery applications . 18 Table A.2 . Recommended use of test
22、s appropriate to types of stationary cells and batteries . 19 Page 4 EN 60896-112003 STATIONARY LEAD-ACID BATTERIES - Part 11: Vented types - General requirements and methods of tests 1 Scope and object This part of IEC 60896 is applicable to lead-acid cells and batteries which are designed for serv
23、ice in fixed locations (.e. not habitually to be moved from place to place) and which are permanently connected to the load and to the d.c. power supply. Batteries operating in such a p p I i ca t i o n s a re ca I I e d “s ta t i o n a r y batter i e s I. Any type or construction of lead-acid batte
24、ry may be used for stationary battery applications. This part 11 of the standard is applicable to vented types only. The object of this standard is to specify general requirements and the main characteristics, together with corresponding test methods associated with all types and construction modes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN60896112003ENSTATIONARYLEADACIDBATTERIESPART11VENTEDTYPESGENERALREQUIREMENTSANDMETHODSOFTESTS 固定 式铅酸

链接地址:http://www.mydoc123.com/p-719114.html