《EN 3661-006-2006 en Aerospace series - Circuit breakers single-pole temperature compensated rated current 20 A to 50 A - Part 006 With polarized signal contact - Bus bar version - .pdf》由会员分享,可在线阅读,更多相关《EN 3661-006-2006 en Aerospace series - Circuit breakers single-pole temperature compensated rated current 20 A to 50 A - Part 006 With polarized signal contact - Bus bar version - .pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 3661-006:2006Aerospace series Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A Part 006: With polarized signal contact Bus bar version Product standardThe European Standard EN 3661-006:2006 has the status of a British StandardICS 49.060g49g50g3
2、g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 3661-006:2006This British Standard was published under the authority of the Standards Policy and Strat
3、egy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 50008 4National forewordThis British Standard was published by BSI. It is the UK implementation of EN 3661-006:2006.The UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic
4、 technology, to Panel ACE/6/-/5, Aerospace Protection for electrical systems.A list of organizations represented on ACE/6/-/5 can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct app
5、lication.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 3661-006August 2006ICS 49.060English VersionAerospace series - Circuit breakers, single-pole, temperatu
6、recompensated, rated current 20 A to 50 A - Part 006: Withpolarized signal contact - Bus bar version - Product standardSrie arospatiale - Disjoncteurs unipolaires compenss entemprature, intensits nominales 20 A 50 A - Partie 006: Avec contact de signalisation polaris - Version pourbarres bus - Norme
7、 de produitLuft- und Raumfahrt - Schutzschalter, einpolig,Temperaturkompensiert, Nennstrme von 20 A bis 50 A -Teil 006: Mit polarisiertem Signalkontakt -Sammelschienenversion - ProduktnormThis European Standard was approved by CEN on 5 June 2006.CEN members are bound to comply with the CEN/CENELEC I
8、nternal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN memb
9、er.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are
10、 the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and Uni
11、ted Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3661-006:2006:
12、E2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Dimensions and mass.4 4 Characteristics.6 5 Designation 10 6 Rated current code 11 7 Delivery codes11 8 Marking .11 9 Technical specification .11 EN 3661-006:20063 Foreword This European Standard (EN 3661-006:2006) has been prepared by
13、the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of the member countries of A
14、SD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standards shall be withdrawn at the latest by February 2007. Attention
15、 is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
16、following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
17、 Spain, Sweden, Switzerland and the United Kingdom. EN 3661-006:20064 1 Scope This standard specifies the characteristics of single-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between 55 C and 125 C and at
18、 an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single push button (actuator), with delayed action “trip-free“ tripping with a polarized signal contact which is open when main contacts are closed, and inversely. They are connected on supply side by means of bus-
19、bar. They will continue to function up to the short-circuit current. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced do
20、cument (including any amendments) applies. EN 3155-016, Aerospace series Electrical contacts used in elements of connection Part 016: Contacts, electrical, male, type A, crimp, class S Product standard. EN 3661-001, Aerospace series Circuit breakers, single-pole, temperature compensated, rated curre
21、nt 20 A to 50 A Part 001: Technical specification. EN 3841-305, Aerospace series Circuit breakers Test methods Part 305: Short-circuit performance. EN 6113, Aerospace series Circuit breaker, connecting and attachment hardware.1)TR 6083, Aerospace series Cut-outs for installation of electrical compon
22、ents.2)MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III, class 2, composition C.3)MIL-I-81969/14C, Installing and removal tools, connector electrical contact, type III, class 2, composition B.3)MIL-S-19500, Semiconductor device, diode, silicon, fast recovery.3)FED
23、-STD-595B, Colors used in Government Procurement. 3 Dimensions and mass 3.1 Dimensional characteristics The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be adhered to. Dimensions are in millimetres. See Figure 1. 1) Published as AECMA Pres
24、tandard at the date of publication of this standard. 2) Published as AECMA Technical Report at the date of publication of this standard. 3) Published by: Department of Defense (DOD), the Pentagon, Washington D.C. 20301 USA. EN 3661-006:20065 1155323M12 x 0,75 10,4 0,43 min.2 0,3482519,5 max.34 max.4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN36610062006ENAEROSPACESERIESCIRCUITBREAKERSSINGLEPOLETEMPERATURECOMPENSATEDRATEDCURRENT20ATO50APART006WITHPOLARIZEDSIGNALCONTACTBUSBARVERSIONPDF

链接地址:http://www.mydoc123.com/p-711118.html