ECA EIA-364-90-2013 TP-90 Crosstalk Ratio Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems.pdf
《ECA EIA-364-90-2013 TP-90 Crosstalk Ratio Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-90-2013 TP-90 Crosstalk Ratio Test Procedure for Electrical Connectors Sockets Cable Assemblies or Interconnection Systems.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-90 Crosstalk Ratio Test Procedure for Electrical Connectors, Sockets, Cable Assemblies or Interconnection Systems EIA-364-90 January 2000 EIA-364-90 ANSI/EIA-364-90-2000 (R2013) Approved: January 13, 2000 Reaffirmed: January 28, 2013 NOTICE EIA Engineering Standards and Publications
2、 are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Ex
3、istence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those othe
4、r than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, no
5、r does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the
6、 EIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine
7、 the applicability of regulatory limitations before its use. Created under Standards Proposal No. 3404 and reaffirmed under Standards Proposal No. 5253.04 under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards). Published by Electronic Components Industry Associa
8、tion 2013 Engineering Department 2214 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a l
9、icense agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-877-413-5184), International (303-397-7956) i Clause 1 CONTENTS Introduction Page11.1 Scope 11.2 Object . 11.3 Definitions 12 Test resources . 22.1 Equipment 22.2 Fixture 33 Test
10、specimen . 43.1 Description . 44 Test procedure 54.1 Method A, time domain . 54.1.1 General . 54.1.2 Insertion technique . 54.1.3 Reference fixture technique 64.1.4 Specimen crosstalk measurement . 64.2 Method B, frequency domain . 74.2.1 General . 74.2.2 Insertion technique . 74.2.3 Reference fixtu
11、re technique 84.2.4 Specimen crosstalk measurement . 95 Details to be specified 95.1 All tests . 95.2 Time domain only 105.3 Frequency domain only 106 Test documentation 11ii CONTENTS (continued) Table Page 1 Recommended measurement system rise time (including fixture and filtering) 6 Figure 1 Wavef
12、orm . 11 A.1 Technique diagram . A-1 A.2 Single-ended terminations A-2 A.3 Differential (balanced) terminations A-3 A.4 Example of far end crosstalk with balanced terminations see figure A.3.a (2nd) and figure A.3.b for Zo = 100 A-4 Annex A Normative . A-1 B Informative . B-1 EIA-364-90 Page 1 TEST
13、PROCEDURE No. 90 CROSSTALK RATIO TEST PROCEDURE FOR ELECTRICAL CONNECTORS, SOCKETS, CABLE ASSEMBLIES OR INTERCONNECT SYSTEMS (From EIA Standards Proposal No. 3404, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards) 1 Introduction 1.1 Scope This procedure applies to
14、 interconnect assemblies, such as electrical connectors, sockets and cable assemblies. 1.2 Object This standard describes test methods for measuring the magnitude of the electromagnetic coupling between driven and quiet lines of an interconnect assembly. Both time domain (method A) and frequency dom
15、ain methods (method B), single-ended and differential transmission, and insertion and reference fixture techniques are described. 1.3 Definitions 1.3.1 Drive signal For the time domain method, the drive signal is a step waveform. For the frequency domain method, the drive signal is sinusoidal. 1.3.2
16、 Crosstalk ratio The ratio of the signal coupled (induced) into the quiet signal conductor or conductor pair to the magnitude of the signal in the driven conductor or conductor pair. Both signals shall have the same units of either voltage or current, and the ratio may be expressed as percent or dB.
17、 1.3.3 Near end crosstalk ratio (NEXT) The crosstalk ratio calculated on the quiet line at or in proximity to the sending (signal source) end of the driven line. This is the ratio of the near end quiet line signal amplitude to the near end driven line signal amplitude. EIA-364-90 Page 2 1.3.4 Far en
18、d crosstalk ratio (FEXT) The crosstalk ratio calculated on the quiet line at or in proximity to the receiving (destination) end of the driven line. This is the ratio of the far end quiet line signal amplitude to the near end driven line signal amplitude. 1.3.5 Measurement system rise time Rise time
19、measured with fixture in place, without the specimen, and with filtering (or normalization). Rise time is typically measured from 10% to 90% levels. 1.3.6 Specimen environment impedance The impedance presented to the specimen signal conductors by the fixture. This impedance is a result of transmissi
20、on lines, termination resistors, attached receivers or signal sources, and fixture parasitics. 1.3.7 Step amplitude The voltage difference between the 0% and 100% levels, ignoring overshoot and undershoot, as indicated in figure 1. 1.3.8 Isolation standard A reference fixture without a test specimen
21、 and with identical crosstalk characteristics as the test fixture. This fixture may or may not be part of the test board. 1.3.9 Termination (electronics usage) An impedance connected to the end of a transmission line, typically to minimize reflected energy on the line. 2 Test resources 2.1 Equipment
22、 2.1.1 Method A, time domain 2.1.1.1 A step generator is used on the driven line and an oscilloscope monitors the quiet line. In a differential application both shall be able to process differential signals. Typically, this means complementary outputs with provision for amplitude and skew adjustment
23、, and dual inputs with a display of the difference and sum. Filtering or normalization shall be available for varying the rise time. A time domain reflectometer (TDR) is usually used. EIA-364-90 Page 3 NOTE - The test professional should be aware of limitations of any math operation(s) performed by
24、an instrument, (e.g. normalization or software filtering). 2.1.1.2 Probes Probes, when used, shall have suitable rise time performance and circuit loading characteristics (e.g. resistance and capacitance). 2.1.2 Method B, frequency domain A network analyzer is preferred. When greater dynamic range i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA364902013TP90CROSSTALKRATIOTESTPROCEDUREFORELECTRICALCONNECTORSSOCKETSCABLEASSEMBLIESORINTERCONNECTIONSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-704330.html