《ECA 502-A-1989 Recommended Practice for Measurement of X-Radiation from Non-Raster-Scanned Direct-View Cathode Ray Tubes《从Non-Raster-Scanned直接查看阴极射线管中泄露的X射线测量的推荐实践》.pdf》由会员分享,可在线阅读,更多相关《ECA 502-A-1989 Recommended Practice for Measurement of X-Radiation from Non-Raster-Scanned Direct-View Cathode Ray Tubes《从Non-Raster-Scanned直接查看阴极射线管中泄露的X射线测量的推荐实践》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、- - EIA 502-A 89 W 3234600 0071943 2 = L. -3 tiGEEis ANSI/ EIA-502-A-198 9 APPROVED: February 9, 1989 O a I Cu O ln I w 0 EIA STANDARD Recommended Practice for Measurement of X-Radiation from Non-Raster-Scanned -Direct-View Cathode Ray Tubes EIA-502-A MARCH 1989 ELECTRONIC INDUSTRIES ASSOCIATION ENG
2、INEERING DEPARTMENT _ EIA 502-A Bq 3234600 0073944 4 . NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting th
3、e purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publication
4、s, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA members, whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adop
5、tion may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Recommended Standard or Publication. This EIA Standard is considered to have international standard
6、ization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable
7、regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. Copyright 1989 Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 1722 E
8、ye Street, N.W. Washington, D.C. 20006 PRICE: $10.00 All rights reserved Printed in U.S.A. .- EIA 502-A 9 3234b00 0073945 b a EIA-502-A RECOMMENDED PRACTICE FOR MEASUREMENT OF X-RADIATION FROM NON-RASTER-SCANNED DIRECT-VIEW CATHODE RAY TUBES TABLE OF CONTENTS Parasraph 1.0 2.0 3.0 4.0 5.0 6.0 7.0 PU
9、RPOSE 1.1 Scope APPARATUS 2.1 X-Radiation Detection Instruments 2.2 Test Equipment CALIBRATION TEST CONDITIONS 4.1 Tube Position 4.2 External Components 4.3 Warm-up 4.4 Display 4.5 Reference Anode Current 4.6 Limiting Conditions SEARCH PROCEDURE 5.1 Initial Display Size and Position 5.2 Tube Electri
10、cal Conditions 5.3 Search Areas 5.4 Final Display Size and Position MEASUREMENT PROCEDURE 6.1 Principal X-Radiation Measuring 6.2 Hypothetical Cabinet 6.3 Measurement REPORT instrument Positioning Paqe 1 1 2 2 3 4 4 6 6 7 7 8 8 8 9 9 9-10 EIA 502-A 89 E 3234600 007194b 8 TABLE OF CONTENT (Contd) Pas
11、e FIGURES : 1A: Display Size and Position A (Rectangular-Screen CRT) 1B: Display Size and Position A (Circular-Screen CRT) 2A: Display Positions (Bl, B2, B3, B4) (Rectangular-Screen CRT) 2B: Display Position (Bl, B2, B3, B4) (Circular- Screen CRT) 3: Hypothetical Cabinet aa 12 13 a4 15 ELA 502-A 89
12、3234b00 0073947 T EIA-5 O 2 -A Page 1 RECOMMENDED PRACTICE FOR MEASUREMENT OF X-RADIATION FROM NON-RASTER-SCANNED DIRECT-VIEW CATHODE RAY TUBES (From EIA Standards Proposal No. 2149, formulated under the cognizance of EIA JT-32 Committee on Electron Tube Safety.) 1.0 PURPOSE The purpose of this Stan
13、dard is to obtain the x-radiation characteristics of non-raster-scanned direct-view data display cathode ray tubes in order to predict the levels emitted by tubes when electrical characteristics of the application are known. 1.1 Scope This test method applies to the measurement of x-radiation emitte
14、d from non-raster-scanned direct-view cathode ray tubes. For some applications the test procedures described in Recommended Standard EIA-501, IlRecommended Practice for the Measurement of X-Radiation from Raster-Scanned Direct-View Data Display Cathode Ray Tubes,“ or EIA-503, IIRecommended Practice
15、for Measurement of X-Radiation from Direct-View Television Picture Tubes, It may be more appropriately used than those described herein. CAUTION SAFETY CONSIDERATIONS Measuring instruments should be properly grounded. Caution should be taken to avoid shock hazard, particularly in the vicinity of the
16、 anode connection and the voltage metering systems. Safety equipment should be worn at times during the measurement procedure. X-ray film badges should be worn in accordance with established plant safety practices for monitoring radiation dosage. I EIA 502-A 9 m 3234600 L187II948 II m EIA- 5 02 -A P
17、age 2 2.0 APPARATUS 2.1 X-Radiation Detection Instruments 2.1.1 Search Instruments A rapid response instrument, designed to detect low energy x-radiation, is recommended te locate the position of instruments such as the Texas Nuclear Model 2652; the Johnson TV X-1; or the Victoreen Model 491). Thin
18、window ion chamber survey meters may also be used. See EIA-Consumer Products Engineering Bulletin No. 3, tvMeasurement Instrumentation for X-Radiation from Television Receiverstt. maximum radiation. (Examples: G-M tube 2.1.2 X-Radiation Measuring Instrument The principal x-radiation measuring instru
19、ment shall comply with the requirements of Title 21, Code sf Federal Regulations (CFR), Chapter I, Subchapter J, Section 1020.10, subparagraph (6)- (2), and with EIA Consumer Products Engineering Bulletin No. 3 (CPEB-3). The instrument shall provide x-radiation measurements (mR/h) in the range of th
20、e applicable limit. The x-radiation sensitive volume shall have a cross section parallel to the external surface of the hypothetical cabinet with an area of 10 cm2 and no dimension larger than 5 cm . Measurements deviations due te instruments imprecision, energy dependence and other sources of error
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECA502A1989RECOMMENDEDPRACTICEFORMEASUREMENTOFXRADIATIONFROMNONRASTERSCANNEDDIRECTVIEWCATHODERAYTUBES

链接地址:http://www.mydoc123.com/p-704045.html