1、I A-A-53727 65 m 3937774 0032474 7 m .-. - A-A-53 9 27 22 June 1989 COMMERCIAL ITEM DESCRIPTION INFUSOR, PRESSURE, BLOOD-INTRAVENOUS BAG The General Services Administration has authorized the use of this commercial item description. This commerical item description covers expendable pressure infusor
2、s suitable for use with intravenous bags of 500 mi and 1000 mi capacity. Salient characteristics: General. Shall be an expendable pressure infusor bag for use with invasive blood pressure monitoring and intravenous infusion procedures. Infusor shall be suitable for use in an operating room environme
3、nt. Style, design and dimensions. The infusor bag shall be in accordance with Figure 1. Material. Infusor shall be a polyurethane coated nylon bag with an attached white netting (mesh) pocket of polyester material to enclose a blood or medication bag of the capacity shown on Figure 1. Construction.
4、Netting shown on Figure 1 shall allow visualization of enclosed bag contents. The braided polyester strap shall be provided to suspend the infusor. The piston type pressure gauge shall be provided at the bottom of the bag with a pressure range of O to 400 mm of Hg for measuring the bladder air press
5、ure. The gauge shall be color-coded and numerically marked to indicate infusor air pressure. Pressure markings shall be at least three in number and shall be provided at O mm Hg, 150 mm Hg and 300 mrn Hg. The gauge shall be clearly visible from 360 degrees. fabricated of ABS plastic with an acetal p
6、iston. Gauge body shall be The bladder and inflation blub shall be connected with approximately 15 inches of vinyl tubing. The inflation bulb shall be fabricated of rubber material and shall be furnished with metal valves fabricated of corrosion-resisting material tio allow the bag to be inflated. T
7、h stopcock shall be used to lock and release the bladder pressure and shall be fabricated of a polycarbonate body, polyethylene stem and an ABS cap. to withstand an air pressure of 600 mm Hg without leakage or other damage. The strap shall withstand a force of 6 lbs. without breaking, fraying, pulli
8、ng free from the bag or other damage. Force shall be applied to the strap,away from and on the longitudinal axis of the bag. The air system shall be designed AMSC N/A FSC 6515 DISTRIBUTION STATEMENT A. Approved for public release; d-istribution is unlimited. /- Y THIS DOCUMENT CONTAINS i“ PAGES. Pro
9、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-* 1“ A-A-5329 7 Workmanship. The infusors shall be free from efects which detract rom their appearance or impair their serviceability. Infusors shall be cet? from cuts, tears, discoloration or other damage
10、. - Unit. Each (EA) One infusor, as specified, constitutes one unit. Quality Assurance Provisions. contract or purchase orer, the contractor is responsible for the performance of all inspection requirements as specified herein. Except: as otherwise epecified in the contract or purchase ordec, the co
11、ntractor may use his own or any facilities suitable for the pexformance of the inspection requirements specifie herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set orth in the specification where euch inspections are deeme necessary t
12、o assure supplies an services eonform to prescribed requirements. Responsibility or Inspection. Unless otherwise specified in the Records. Records of examinations and tests performed by or for the contractor ehaZ1 be maintained by the contractor and made avaiLabLe to the Government upon the Governme
13、nts request, at any time, or from time to time, during the performance of the contract and for a period of thiee years after delivery of the supplies to which such records xslate. Znspeetion. Inspection, as used herein, is define8 as both examination (such as visual or auitory invescigation without:
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA539271989INFUSORPRESSUREBLOODINTRAVENOUSBAG 静脉 血液 袋子 压力 PDF

链接地址:http://www.mydoc123.com/p-701695.html