1、 MIL-PRF-1/422J 2 July 2004 SUPERSEDIING MIL-PRF-1/422H 12 October 1998 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, CATHODE RAY TYPES 7YP1, 7YP2, AND 7YP7 This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The requirements for acquiring the elec
2、tron tube described herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Electrostatic deflection and focus, square face, five beam. DIMENSIONS AND PIN CONNECTIONS: See figure 1. ABSOLUTE RATINGS: Parameter: Ef Ec1 Eb1 Eb2 Eb3 ed Rg Zd Ehk Eb3/Eb2 Unit: V V dc V dc V
3、 dc V dc v Meg Meg V dc Ratio Maximum: 6.9 -200 1,650 3,850 7,700 1,250 1.5 1.0 see note 1 180 2.0 see note 2 Minimum: 5.7 0 - - - - - - - - - - - - - - - - - - - - - - - - Test conditions: see note 3 6.3 Adjust focus 2,000 4,000 - - - - - - 1.0 - - - 2.0 _ GENERAL: Qualification - Required. Prior t
4、o shipment, 7YP2 tubes shall be electrically burned-in on a 100 percent basis. These tubes shall be operated at standard operating conditions with 5 microamperes direct current applied to each gun for a period of 48 hours. During this 48 hour period, the tube shall be turned off for 30 minutes (allo
5、wed to cool) and then turned on to continue burn-in at least 4 times. Following burn-in, each tube shall be tested in accordance with the following MIL-STD-1311 tests: Method Test Method Test 5201 Voltage breakdown 5241 Grid-cutoff voltage 5206 Gas “cross” 5251 Grid No. 1 leakage current 5223 Modula
6、tion 5251 Anode No. 2 leakage current 5231 Spot displacement (leakage) 5201 Electrode current (Anode No. 1) Those tubes which fail any of these tests shall not be shipped. Visual inspections shall be made to ensure that all JAN 7YP2 CRTs are failure free from arcing for continuous and intermittent o
7、perational testing during all manufacturing and acceptance testing. Pressure test method 1141 shall be performed, except 30 pounds per square inch (PSI) absolute pressure shall be applied in lieu of 45 PSI absolute, on a 100 percent basis prior to shipment for the JAN 7YP2 tube only. Only those tube
8、s meeting the acceptance criteria for this test shall be shipped. When a P2 CRT screen is specified, the phosphors shall be in compliance with Electronic Industries Alliance TEPAC Publication, TEP 116-B, Optical Characteristics of Cathode Ray Tubes. AMSC N/A FSC 5960 INCH-POUND Provided by IHSNot fo
9、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/422J 2TABLE I. Testing and inspection. Inspection Method MIL-STD-1311 Notes Conditions Symbol Limits Min Limits Max Unit Conformance inspection, part 1 Voltage breakdown Voltage breakdown (electrostatic types) Gas
10、 “cross” Bulb, screen and faceplate quality Light output Modulation Spot position (electrostatic deflection) Spot displacement (leakage) Grid cutoff voltage Grid No. 1 leakage current Anode No. 2 leakage current 5201 5201 5206 5106 5221 5223 5231 5231 5241 5251 5251 - - - - - - 6, 11 - - - 11 11 - -
11、 - 8 - - - - - - - - - - - - Ib3 = 50 A dc P1 screen; Ib3 = 50 A P2 screen; Ib3 = 50 A, for 7YP2 only Ib3 = 50 A dc - - - - - - - - - - - - Light Light Ec1 - - - - - - Ec0 Ic1 Ib2 - - - - - - - - - - - - 25 25 - - - - - - - - - -90 - - - - - - - - - - - - - - - - - - - - - - - - 55 16 10 -50 3 10 -
12、- - - - - - - - - - - ftL ftL V dc mm mm V dc A dc A dc Conformance inspection, part 2 Screens Type P2 Type P7 Type P7 Heater current Electrode current (anode No. 1) Electrode current (cathode) Base alignment (electrostatic types) Trace and bulb alignment (rectangular electrostatic types) Side termi
13、nal alignment (electrostatic types) 5221 1301 5201 5201 5101 5101 5101 11, 13 11, 13 11, 13 - - - - - - - - - - - - - - - - - - Ib3 = 50 A dc 3D4; base key 1D2 trace and bulb wall with contact button 3D4 D1(1) D1(5) G5:1 Ib Ib1 Ik - - - - - - - - - 360 400 4 540 -15 - - - - - - - - - - - - - - - - -
14、 - - - - 660 +10 1,000 - - - 3 - - - cB cB cB mA A dc A dc - - - Degrees - - - See notes at end of table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/422J 3TABLE I. Testing and inspection -Continued. Inspection Method MIL-STD-1311 Not
15、es Conditions Symbol Limits Min Limits Max Unit Conformance inspection, part 2 - Continued Side terminal and base alignment Neck and base alignment (electrostatic types) Line width “A” (electrostatic deflection) Line width “B” (electrostatic deflection) Focusing voltage at Ib = 25 A direct current D
16、eflection factor Deflection factor Heater-cathode leakage current Angle between traces Trace alignment Base pin solder depth Secureness of base, cap or insert Permanence of marking 5101 5101 5226 5226 5246 5248 5248 5251 5101 - - - 1111 1101 1105 - - - - - - 7 - - - 9 10 - - - - - - 12 - - - 15 - -
17、- Base key, collar index pin Ib3 = 25 A dc Ib3 = 25 A dc 1D2 3D4 Sample size shall be 1 percent of lot (lot = 1 months production) For qualifications only. - - - - - - Width Width Eb1 DF DF Ihk - - - - - - - - - - - - - - - - - - - - - - - - - - - 450 68 27 - - - 88 - - - - - - - - - - - - - - - - -
18、 - 0.65 0.80 650 80 37 15 92 - - - 0 failures - - - - - - - - - - - - mm mm V dc V dc/in. V dc/in. A dc Degrees - - - - - - - - - - - - Conformance inspection, part 3 Life test Life-test end points: Modulation Line width “A” Line width “B” Pressure (implosion) Vibration - - - - - - 5223 5226 5226 11
19、41 5111 14 - - - - - - - - - 5 5 Group C; t = 500 hours; Ib3 = 25 A dc Ib3 = 40 A dc Ib3 = 18 A dc Ib3 = 18 A dc For qualification only. - - - Ec1 Width Width - - - Width - - - - - - - - - - - - - - - - - - - - - 55 0.65 0.80 - - - 1.0 - - - V dc mm mm - - - mm See notes at end of table I. Provided
20、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/422J 4TABEL I. Testing and inspection -Continued. Inspection Method MIL-STD-1311 Notes Conditions Symbol Limits Min Limits Max Unit Conformance inspection, part 3 - Continued Direct-interelectrode capa
21、citance Neck and bulb alignment (electrostatic types) Stray light emission (conventional types) Cathode illumination Deflection-factor uniformity Interaction factor Shock Base material insulating quality 1331 5101 5216 5216 5248 5250 5115 1216 4, 5 5 5 5 5 5 5 5 k to all g1 to all D1 to D2 D3 to D4
22、D1 to all D2 to all D3 to all D4 to all Eb2 = 3,850 V dc; Eb3 = 7,700 V dc For qualification only 1D2 3D4 For qualification only For qualification only Ck Cg1 C1D2 C3D4 CD1 CD2 CD3 CD4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF1422J2004ELECTRONTUBECATHODERAYTYPES7YP17YP2AND7YP7PDF

链接地址:http://www.mydoc123.com/p-692063.html