1、 REVISIONS LTR DESCRIPTION DATE APPROVED Prepared in accordance with ASME Y14.100 REV STATUS OF PAGES REV PAGES 1 2 3 4 5 6 7 8 9 10 PMIC N/A PREPARED BY Fred W. Lester DESIGN ACTIVITY DLA LAND AND MARITIME COLUMBUS, OH Original date of drawing 9 July 13 CHECKED BY Kurt L. Anderson TITLE FUSE, INSTR
2、UMENT, SUBMINIATURE APPROVED BY Michael A. Radecki SIZE A CODE IDENT. NO. 037Z3 DWG NO. 13031 REV PAGE 1 OF 10 AMSC N/A 5920-2013-E01 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG
3、 NO. 13031 REV PAGE 2 1. SCOPE 1.1 Scope. This drawing describes the requirements for a family of subminiature instrument type fuses for use in overcurrent protection. 1.2 Part or Identifying Number (PIN). The complete PIN shall be as follows: 13031 -001 A Drawing number Dash number (see table II) C
4、haracteristic (see 3.5) 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. W
5、hile every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and
6、handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-15160 - Fuses, Instru
7、ment, Power, and Telephone, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts. MIL-STD-1285 - Marking of Electrical and Electronic Parts. (Copies of these documents are available online at http:/quicksearch.dla.mil/ or
8、 https:/assist.dla.mil or from DLA Document Services, Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents are thos
9、e cited in the solicitation or contact. JEDEC SOLID STATE TECHNOLOGY ASSOCIATION J-STD-020D.1 - Moisture/Reflow sensitivity Classification for Nonhermetic Solid State Surface Mount Devices. (Copies of this document are available online at http:/www.jedec.org/ or from JEDEC, 3103 North 10thStreet, Su
10、ite 240-S, Arlington, VA 22201-2107.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exe
11、mption has been obtained. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13031 REV PAGE 3 3. REQUIREMENTS 3.1 Interface and physical dimensions. The individual item requirement
12、s shall be as specified herein and in table I and table II. 3.2 Operating temperature range. The operating temperature range shall be -55C to +125C. 3.3 Moisture sensitivity level. The moisture sensitivity level shall be level 1 in accordance with J-STD-020D.1. 3.4 Materials. This fuse shall have a
13、ceramic body with silver plated caps. 3.5 Electrical characteristics and other requirements. Each PIN (see 1.2) shall include a suffix representing either characteristic A or B. These characteristics are described in table I. 3.6 Voltage rating. See table II. 3.7 Current rating. See table II. 3.8 Di
14、mensions and configurations. See figure 1. 3.9 Current-carrying capacity. Current-carrying capacity shall be in accordance with MIL-PRF-15160 and table I. 3.10 Overload interrupt. Overload interrupt shall be in accordance with MIL-PRF-15160 and table I. Provided by IHSNot for ResaleNo reproduction o
15、r networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13031 REV PAGE 4 Ltr mm Inches Min Max Min Max A 5.90 6.30 0.232 0.248 B - .145 - 0.006 C 2.44 2.94 0.096 0.116 D - 6.86 - 0.270 E - 3.15 - 0.124 F - 1.96 - 0.077 G - 2.95 - 0
16、.116 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. FIGURE 1. Design and dimensions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 D
17、WG NO. 13031 REV PAGE 5 TABLE I. Characteristics. Characteristic Rating (percent) Opening time A 100 4 hours, minimum A 200 10 seconds, maximum (.62 ampere to 10 ampere) A 200 30 seconds, maximum (12 ampere to 15 ampere) B 100 4 hours, minimum B 200 1 second, minimum 1 minute, maximum TABLE II. Fuse
18、 dash number and applicable characteristics. DLA Land and Maritime drawing PIN 13031- Current rating (amperes) Configuration Voltage rating AC short circuit interrupt 125 volts ac 125 volts dc 001 1/16 A 125 50 A 50 A 002 8/100 A 125 50 A 50 A 003 1/10 A 125 50 A 50 A 004 1/8 A 125 50 A 50 A 005 16/
19、100 A 125 50 A 50 A 006 2/10 A 125 50 A 50 A 007 1/4 A 125 50 A 50 A 008 315/1000 A 125 50 A 50 A 009 3/8 A 125 50 A 50 A 010 3/8 B 125 50 A 50 A 011 4/10 A 125 50 A 50 A 012 1/2 A 125 50 A 50 A 013 1/2 B 125 50 A 50 A 014 63/100 A 125 50 A 50 A 015 3/4 A 125 50 A 50 A 016 3/4 B 125 50A 50 A 017 8/1
20、0 A 125 50 A 50 A 018 1 A 125 50 A 50 A 019 1 B 125 50 A 50 A 020 1 1/4 A 125 50 A 50 A 021 1 1/2 A 125 50 A 50 A 022 1 1/2 B 125 50 A 50 A 023 1 6/10 A 125 50 A 50 A Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHI
21、O SIZE A CODE IDENT NO. 037Z3 DWG NO. 13031 REV PAGE 6 TABLE II. Fuse dash number and applicable characteristics - continued. DLA Land and Maritime drawing PIN 13031- Current rating (amperes) Configuration Voltage rating AC short circuit interrupt 125 volts ac 125 volts dc 024 2 A 125 50 A 50 A 025
22、2 B 125 50 A 50 A 026 2 1/2 A 125 50 A 50 A 027 2 1/2 B 125 50 A 50 A 028 3 A 125 50 A 50 A 029 3 B 125 50 A 50 A 030 3 15/100 A 125 50 A 50 A 031 3 1/2 A 125 50 A 50 A 032 3 1/2 B 125 50 A 50 A 033 4 A 125 50 A 50 A 034 4 B 125 50 A 50 A 035 5 A 125 50 A 50 A 036 5 B 125 50 A 50 A (72 volts, dc) 03
23、7 6 3/10 A 125 50 A 50 A 038 7 A 125 50 A 50 A 039 7 B 72 50 A 50 A (72 volts, dc) 040 8 B 72 50 A 50 A (72 volts, dc) 041 10 A 125 35A 50 A 042 12 A 125 50 A (65 volts dc) 50 A (65 volts dc) 043 12 B 72 50 A 50 A (72 volts, dc) 044 15 A 125 50 A (65 volts dc) 50 A (65 volts dc) 3.11 Short circuit i
24、nterrupt. Short circuit interrupt shall be in accordance with MIL-PRF-15160 and table II. 3.12 Solderability. Solderablility shall be in accordance with MIL-STD-202, method 208. 3.13. Insulation resistance (after opening). Insulation resistance (after opening) shall be in accordance with MIL-STD-202
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG130312013FUSEINSTRUMENTSUBMINIATUREPDF

链接地址:http://www.mydoc123.com/p-688746.html