1、AMSC N/A FSC 2910 INCH-POUND A-A-59535A 9 December 2013 SUPERSEDING A-A-59535 2 February 2000 COMMERCIAL ITEM DESCRIPTION PUMP, FUEL, ELECTRICAL: 12 AND 24 VOLT DC The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This
2、commercial item description (CID) covers the general requirements for pump, fuel, electrical: 12 and 24 volt DC. Pump, fuel, electrical: 12 and 24 volt DC covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION/PART OR IDENTIFICATION NUMBER (PIN). This CID uses a c
3、lassification system which is included in the PIN as shown in the following example (see 7.1). AA59535 - 001 CID number Type code 2.1 CID codes for types: CID code 001 = type I (12 VDC nominal) CID code 002 = type II (24 VDC nominal) Beneficial comments, recommendations, additions, deletions, clarif
4、ications, etc., and any data that may improve this document should be sent to: DLA Land and Maritime, ATTN: VAI, P.O. Box 3990, Columbus OH 432183990, or email fluidflow.dla.mil. Since contact information can change you may want to verify the currency of the address information using the ASSIST Onli
5、ne database at https:/assist.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59535A 2 3. SALIENT CHARACTERISTICS. 3.1 Interface and physical dimensions. Pump, fuel, electrical: 12 and 24 volt DC supplied to this CID shall be as specifie
6、d herein. 3.1.1 Envelope. The external dimensions of the pump shall conform to the envelope dimensions shown on figure 1. 3.1.2 Fuel filter. The pump shall incorporate a fuel filter to protect the fuel supply system. The filter shall be removable for cleaning without demounting the pump. 3.1.3 Inlet
7、 and outlet connections. The inlet and outlet connections shall be threaded to interface with the mating threaded part. Internal threads shall be 0.1250 - 27 NPT (American National Standard Taper Pipe Threads) and external threads shall be 0.2500 - 18 NPT. If internal threads are used on the pump, a
8、 threaded adapter shall be provided with external threads of 0.2500 - 18 NPT. The adapter shall not protrude from the pump body more than 0.5 inches. 3.1.4 Electrical connector and cable. The electrical connector shall be as shown on figure 1. The electrical connector shall withstand a pull of not l
9、ess than 60 pounds. The mated connector shall not require more than 30 pounds to separate from its mate at a temperature of -55 degrees Fahrenheit (F). The cable shall conform to MIL-DTL-13486 type I, class A, or equal. When necessary, part or all of the cable may conform to MIL-DTL-13486 type II, c
10、lass A, or equal, provided that a separate cable ground is used. Cables shall exit the pump within or before the area marked “CABLE CLEARANCE” shown on figure 1. Both the cable and the cable ground shall be external to the pump body and shall be located within the cable clearance area shown on figur
11、e 1. The cable shall be flexible down to -55 F. The junction between the connector and cable shall be waterproof. The boot attached to the power cable shall be made of rubber ASTM D2000 M5BC 610 A14E034F19 Z1 (Z1 is method B of C12) in accordance with ASTM D2000, or equal. 3.2 Performance. 3.2.1 Fue
12、l compatibility. The pump shall be capable of operating with the following fuels: a. Diesel fuel oil, grades 1-D and 2-D, conforming to ASTM D975. b. Diesel fuel oil conforming to A-A-52557. c. Jet A-1 turbine fuel conforming to ASTM D1655. 3.2.2 Output. The output of each pump type shall equal or e
13、xceed the applicable performance curve shown on figure 2 when operated at temperatures between 65 and 75 F. The pump fuel flow, at any given pressure, shall be not less than 67% of the value shown in figure 2 in ambient temperatures ranging from -55 to +65 F. 3.2.3 Electrical. The pump shall operate
14、 within the voltage range listed in table I. The negative terminal of the pump shall be connected to ground. The load current shall not exceed 1.75 amperes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59535A 3 TABLE I. DC voltage. Pump type N
15、ominal voltage Minimum voltage Maximum voltage I 12 6 18 II 24 18 30 3.2.4 Electromagnetic interference suppression. Conducted emissions and radiated emissions on power leads shall not exceed the values shown on figures 3 and 4, respectively. 3.2.5 Dry operation. The pump shall be capable of withsta
16、nding dry pumping operation for a period of not less than 4 hours without evidence of damage or impairment of performance. 3.2.6 Dry prime. The pump shall be capable of commencing and maintaining fuel pumping operation from a dry condition with the fuel source not less than 2.5 feet below the bottom
17、 of the pump. 3.2.7 Endurance. The pump shall maintain a delivery versus pressure relationship not less than that specified in 3.2.2 for a period of not less than 3,000 hours. 3.3 Materials. Materials shall conform to the manufacturers materials specifications for pumps. Asbestos, cadmium, and radio
18、active materials defined by Title 10, Code of Federal Regulations (CFR), Part 40, and other radioactive material in which the radioactivity is greater than 0.002 microcuries per gram or 0.01 microcuries total activity, shall not be incorporated into the pump assembly. 3.4 Environmental conditions. 3
19、.4.1 Storage temperature. The pump shall operate after being stored at temperatures ranging from 65 to +160 F. 3.4.2 Vibration resistance. The pump shall show no evidence of damage or leakage and shall meet the output requirements of 3.2.2 when subjected to a simple harmonic motion with an amplitude
20、 of not less than 0.03 inch at a frequency range of 10 to 55 Hz along each of the three mutually perpendicular axes. 3.4.3 Shock resistance. The pump shall show no evidence of damage or leakage and shall meet the output requirements of 3.2.2 when subjected to sawtooth wave shocks (see figure 5) of 2
21、5 gravity units (g) with a nominal duration of 18 milliseconds along each of the three mutually perpendicular axes. 3.4.4 Corrosion resistance. The pump shall resist corrosion resulting from exposure to salt fog . 3.4.5 Fungus resistance. The pump shall be non-nutritive for fungus growth. 3.5 Recycl
22、ed, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cyc
23、le costs. 3.6 Workmanship. Pump, fuel, electrical: 12 and 24 volt DC shall be processed in such a manner as to be uniform in quality and shall be free from other defects that will affect life, serviceability, or appearance. Provided by IHSNot for ResaleNo reproduction or networking permitted without
24、 license from IHS-,-,-A-A-59535A 4 4. REGULATORY REQUIREMENTS. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with 23.403 of the Federal Acquisition Regulation (FAR). 5. PRODUCT CONFORMANCE PROVISIONS. 5.1 Product conformance. The pro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAAA59535A2013PUMPFUELELECTRICAL12AND24VOLTDCPDF

链接地址:http://www.mydoc123.com/p-687505.html