1、June 2008DEUTSCHE NORM English price group 27No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.140.40!$O Vcis the vol
2、ume in cubic metres (m3)that has actually flowed through the meter 3.1.8 external leak tightness leak tightness of the gas carrying components of the gas meter with respect to the atmosphere 3.1.9 flag single alphabetic character on the index giving a visual signal of significant events and/or chang
3、e(s) in the operation of the meter 3.1.10 galvanic connection/interface hard wired serial connection or pulse output from the meter 3.1.11 index all that which is viewed through the index window, including the display 3.1.12 index window(s) area(s) of transparent material through which the index can
4、 be read 3.1.13 maximum error shift maximum mean error shift at any of the tested flow rates 3.1.14 maximum working pressure upper limit of the working pressure for which the meter has been designed, as declared by the manufacturer and marked on the index or the data plate 3.1.15 mean error arithmet
5、ic mean of consecutive errors of indication at a flow rate 3.1.16 measuring element part of the meter which produces an electrical signal proportional to the gas flow rate DIN EN 14236:2008-06 EN 14236:2007 (E) 12 3.1.17 memory element which stores digital information 3.1.18 meter case complete mete
6、r, not casing only 3.1.19 meter class class to which a meter belongs, according to the metrological requirements of this European Standard, i.e. class 1,5 or class 1,0. 3.1.20 meter cover rigid enclosure on the front of the meter made either wholly of transparent material, or of opaque material prov
7、ided with index window(s) 3.1.21 normal conditions of operation conditions referring to the meter operating: at a pressure up to the maximum working pressure (with or without a flow of gas); within the range of flow rates; within the ambient temperature range; within the gas temperature range; with
8、the distributed gas 3.1.22 operating mode method (sample frequency and timing) of obtaining volume flow measurements 3.1.23 optical port serial data port using an infra-red transmitter and receiver 3.1.24 pressure absorption difference between the pressure measured at the inlet and outlet connection
9、s of the meter whilst the meter is operating 3.1.25 pressure measuring point permanent fitting on the meter outlet enabling a direct measurement of the outlet pressure to be obtained 3.1.26 range of mean errors difference between the minimum and maximum mean errors over a specified flow range 3.1.27
10、 regression line straight line, generated using a statistical method, to give a graphical representation of a set of results DIN EN 14236:2008-06 EN 14236:2007 (E) 13 3.1.28 register electronic device comprising both memory and display, which stores and displays information 3.1.29 segment individual
11、 part of a display which is able to show a portion of a character 3.1.30 starting flow rate lowest flow rate at which the meter is able to indicate a volume of gas passed 3.1.31 temperature conversion device device which converts the measured volume to a corresponding volume at base gas temperature
12、3.1.32 test house organisation used to perform prescribed tests on meters, in accordance with this standard 3.1.33 thermal cut-off valve heat sensitive valve used to cut off the flow of gas to the meter if the ambient temperature rises above a predetermined level for a specified time 3.1.34 ultrason
13、ic gas meter gas meter that uses ultrasound and that is designed to measure, memorise and display the fuel gas volume that has passed through it 3.1.35 ultrasonic transducer device used to generate and detect the ultrasound signals within the meter 3.1.36 working pressure pressure of the gas at the
14、inlet of the meter 3.2 Symbols 3.2.1 D outside diameter of the pipe in millimetres (mm) 3.2.2 g acceleration due to gravity, in metres per square second (m s-2) 3.2.3 MPE maximum permissible error, in percent (%) 3.2.4 pmaxmaximum working pressure DIN EN 14236:2008-06 EN 14236:2007 (E) 14 3.2.5 Qmax
15、 maximum flow rate, specified in cubic metres per hour (m3/h) for which the meter has been designed 3.2.6 Qmin minimum flow rate, specified in cubic metres per hour (m3/h) for which the meter has been designed 3.2.7 Qr overload flow rate, the highest flow rate at which the meter operates for a short
16、 period of time without deteriorating 3.2.8 Qstart lowest flow rate at which the meter is capable of registering the passage of gas, as declared by the manufacturer 3.2.9 Qt transitional flow rate, occurring between the maximum and minimum flow rates at which the flow rate range is divided into two
17、zones, the upper zone and the lower zone NOTE Each zone has a characteristic maximum permissible error 3.2.10 tbbase gas temperature 3.2.11 tb,ibase gas temperature for meters declared suitable for differential temperature and intermittent operation 3.2.12 Ti temperature at meter inlet 3.2.13 tm amb
18、ient temperature of the meter 3.2.14 tg gas temperature range of the meter 3.2.15 tsp specified centre temperature for a temperature converted meter 4 Normal operating conditions 4.1 Flow range The values of maximum flow rates and those corresponding values of the upper limits of the minimum flow ra
19、tes shall be those given in Table 1. DIN EN 14236:2008-06 EN 14236:2007 (E) 15 Table 1 Flow range QmaxUpper limits of Qminm3/h m3/h 2,5 0,016 4 0,025 6 0,040 10 0,060 The definitions of the meter classifications applicable in this European Standard are given in Table 2. Table 2 Flow rate ranges by m
20、eter classification Class Qmax/QminQmax/QtQr/Qmax1,5 150 10 1,2 1,0 150 5 1,2 4.2 Maximum working pressure The manufacturer shall declare the maximum working pressure of the meter and this pressure shall be marked on the index or data plate of the meter. This pressure shall not exceed 0,5 bar. 4.3 T
21、emperature range Unless otherwise stated, all temperatures given in this document shall be measured to within 1 C. All meters shall be capable of meeting the requirements for a minimum ambient temperature range of -10 C to +40 C (see 5.14), a minimum gas temperature span of 40 K and a storage temper
22、ature of -20 C to +60 C. The gas temperature range shall be within the ambient temperature range. The manufacturer shall declare the gas temperature range and the ambient temperature range. The manufacturer can declare a wider ambient temperature range using a minimum temperature of -10 C, -25 C or
23、-40 C and a maximum temperature of 40 C, 55 C or 70 C and/or a wider storage temperature range. The meter shall be capable of meeting the requirements over this declared wider range. If the manufacturer declares that the meter is resistant to high ambient temperatures, the meter shall also be capabl
24、e of meeting the requirements of the heat resistance test and shall be marked accordingly (see 7.2.1 and 9.1). DIN EN 14236:2008-06 EN 14236:2007 (E) 16 4.4 Range of gases 4.4.1 Test gases The manufacturer shall specify the range of gases for which the meter is suitable, from Table 3. Table 3 Gas gr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINEN142362008ULTRASONICDOMESTICGASMETERSENGLISHVERSIONOFDINEN14236200806 超声波 家用 煤气表 PDF

链接地址:http://www.mydoc123.com/p-667097.html