DIN 51750-2-1990 Sampling of liquid petroleum products《液态石油产品的取样》.pdf
《DIN 51750-2-1990 Sampling of liquid petroleum products《液态石油产品的取样》.pdf》由会员分享,可在线阅读,更多相关《DIN 51750-2-1990 Sampling of liquid petroleum products《液态石油产品的取样》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、UDC 665.61.7 : 662.753 : 621.892 : 620.113 DEUTSCHE NORM December 1990 I I Part 2 Prfung von Minerallen; Probenahme; flssige Stoffe Supersedes March 1984 edition. In keeping with current practice in standards published by the International Organization for Standardization (SO), a comma has been used
2、 throughout as the decimal marker. See Explanatory notes for connection with IS0 3170 : 1988 published by the International Organization for Standardization (ISO) and ASTM D 4057-88 published by the American Society for Testing and Materials (ASTM). Dimensions in mm For general tolerances, accuracy
3、grade g as specified in DIN 7168 shall apply 1 This standard describes methods of sampling crude oils and liquid petroleum products (e.9. engine fuels, special boiling point spirits and white spirits, fuel oils, kerosene and liquid lubricants), as well as pasty and solid petroleum products (e.g. lub
4、ricating greases, petroleum jelly and paraffins) which can be liquefied by heating without that changing their composition. It does not cover bituminous binders (cf. EN 58). lubricating oils in internal combustion engines (cf. DIN 51 574), and liquefied natural gas (cf. DIN 51 610). General informat
5、ion on the sampling of petroleum products is provided in DIN 51 750 Part 1. Scope and field of application 2 Apparatus 2.1 Samplers l) Samplersasdescribedinsubclauses2.1.1 to2.1.5are to be selected as a function of the type and size of container from which the sample is to be taken, the brand and gr
6、ade of product to be tested and the type of sample to be collected. To collect samples from group A petroleum products of hazard categories I and Il2), only sampling bottles or bomb- type samplers shall be used that are made entirely (.e. including lifting cord, suspension rod) of an anti-static mat
7、erial or from a material from which sparks cannot be drawn unintentionally (e.g. copper or copper-zinc alloys). During sampling such equipment shall be connected to the container by a metal-to-metal joint. Considerable amounts of electric charge may have accu- mulated in liquid stored in freshly fil
8、led tanks. In such I) Information on sources of supply can be obtained from DIN-Bezugsquellen fr normgerechte Erzeugnisse im DIN Deutsches Institut fr Normung e.V Burggrafen- Strae 6, D-1000 Berlin 30. 2, For hazard categories, see subclause 2.1 of DIN 51 755, March 1974 edition. cases, samples shal
9、l be taken only after the static charge has dissipated (which may take several hours). See clause 4 for further details on the use of samplers. Care shall be taken to ensure that the samplers and their fittings are clean and dry and do not come into contact with possible sources of contamination (cl
10、eaning rags, dust, etc.) and moisture (rain) during sampling. Note. Cleaning wool shall not be used in sections of a plant where group A products of hazard categories I and II are handled. i+ 35 Figure 1. Sampling tube Continued on pages 2 to 5 Beuth Verlag GmbH, Berlin, has the exclusive right of s
11、ale for German Standards (DIN-Normen). DIN 57 750 Part 2 Engl. Price group 6 06.92 Sales No. O106 Page 2 DIN 51 750 Part 2 110 7 Figure 2. Type A thief A-A Centring plate, developed ,19- Spring steel, 1 mm thick B- B Figure 3. Type B thief 2.1.1 Sampling tubes Sampling tubes, asshown in figure 1, ar
12、e tubesof sufficient length and tapered at top and bottom, with an internal diameter of approximately 25 mm. 2.1.2 Thief lubes 2.1.2.1 Type A thief A type A thief, as shown in figure 2, is a tube with a handle at the top, which is connected to a disc at the bottom used to close it via a tension spri
13、ng and a rod. The spring ensures that the thief is completely sealed when the handle is raised and locked in position by turning it through 90. 2.1.2.2 Type B thief A type B thief, as shown in figure 3, consists of a sampling cylinder (4) and a tubular extension (6) of a suitable length, an internal
14、 rod (2) and two disc-type pistons (5) which act as guides and seals, a conical stopper (1) and chain fittings (7 and a), a ring at the bottom end (3) serving to protect the cylinder. 2.1.3 Sampling bottles Sampling bottles may either have the form of a weighted metal beaker, as shown in figure 4, o
15、r of a glass bottle of any type and a weighted metal cage, as shown in figure 5. The bottle (or the cage) and the stopper are attached to a cord which allows the bottle to be lowered to the desired depth in a container. Instead of a cord, a metal rod may be attached to the bottle, but an additional
16、cord shall then be attached to the stopper. The rod shall be connected to the tank by a metal-to-metal joint. See subclause 2.1 for type of metal to be used. A beaker is to be used when collecting samples to deter- mine the vapour pressure, to prevent decanting losses. 3 wire handle Wire lugs Figure
17、 4. Weighted beaker (dimensions given by way of example) DIN 51 750 Part 2 Page 3 Lifting cord 3 to 5 in diameter Hinged flap for retaining Cage accommodating the sampling bottle, Figure 5. Bottle fitted in cage 2.1.4 Bomb-type sampiers Bomb-type samplers, as shown in figure 6, are made of metal as
18、specified in subclause 2.1, with a lug to which a cord is attached permitting the sampler to be lowered to any desired depth in a container, another lug being pro- vided on the rod-and-stopper assembly, to which another cord can be attached for raising and lowering the stopper. 2.1.5 Scoops Scoops s
19、hall be of normal commercial type, with a capacity of about 0,5 1. 2.2 Sample containers For storing the sample collected, a clean, dry, sealable container (e.g. glass bottle, steel can, type-approved plastic spare fuel can bearing a test number) shall be used. If the liquid is readily volatile (.e.
20、 has a Reid vapour pressure of more than 1,12 bar; cf. DIN 51 754), the sample container shall be cooled in ice to prevent evaporation losses. A separate sample container shall be used for each sample. 3 Preparations for sampling 3.1 If the stability of the product to be tested is poor at low temper
21、atures, the bulkshall be heated to about 10 OC above the pour point specified in IS0 3016. 3.2 If the storage tank is provided with a bottom drain valve, any water which may have separated from the product shall be discharged and its quantity recorded. Note that the aqueous bottom layer in petrol ma
22、y be a mixture of water and alcohols. Lug for cord Lug for cord to stoppet attaching -_. IV 4 80 -I Figure 6. Bomb-type sampler (dimensions given by way of example) 3.3 The contents of barrels or other small containers shall be thoroughly mixed before sampling. Where a layer of free water has collec
23、ted in a barrel and cannot be removed, the barrel shall be raised on one side approxi- mately 20 cm and left in this oblique position for not less than half an hour beforesampling, so as to permitthe water and any contaminants to settle. Next, the spot sample shall be taken from the level above the
24、sediments. 3.4 Samplers and sample containers shall be prepared as described in subclauses 2.1 and 2.2. 4 Procedures 4.1 Collecting spot samples 4.1.1 Method using a sampling tube (cf. figure 1) This method is particularly suitable for sampling from smaller containers, such as barrels, drums, etc. T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN5175021990SAMPLINGOFLIQUIDPETROLEUMPRODUCTS 液态 石油 产品 取样 PDF

链接地址:http://www.mydoc123.com/p-658642.html