DIN 5034-6-2007 Daylight in interiors - Part 6 Simplified determination of suitable dimensions for rooflights《室内日光照明 第6部分 采光天窗配合尺寸的简易测定》.pdf
《DIN 5034-6-2007 Daylight in interiors - Part 6 Simplified determination of suitable dimensions for rooflights《室内日光照明 第6部分 采光天窗配合尺寸的简易测定》.pdf》由会员分享,可在线阅读,更多相关《DIN 5034-6-2007 Daylight in interiors - Part 6 Simplified determination of suitable dimensions for rooflights《室内日光照明 第6部分 采光天窗配合尺寸的简易测定》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 February 2007DEUTSCHE NORMDIN-Normenausschuss Lichttechnik (FNL)DIN-SprachendienstEnglish price group 9No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale f
2、or German Standards (DIN-Normen).ICS 91.160.10!%Adn“2306575www.din.deDDIN 5034-6Daylight in interiors Part 6: Simplified determination of suitable dimensions for rooflights,English translation of DIN 5034-6:2007-02Tageslicht in Innenrumen Teil 6: Vereinfachte Bestimmung zweckmiger Abmessungen von Ob
3、erlichtffnungen inDachflchen,Englische bersetzung von DIN 5034-6:2007-02Lumire naturelle lintrieur Partie 6: Dtermination simplifie de dimension convenable de lucarnes,Traduction anglaise de DIN 5034-6:2007-02SupersedesDIN 5034-6:1995-06www.beuth.deDocument comprises 13 pages11.15 DIN 5034-6:2007-02
4、 2 A comma is used as the decimal marker. Contents Page Foreword . 3 Introduction 4 1 Scope . 4 2 Normative references . 4 3 Symbols . 5 4 Daylight factor . 6 5 Simplified assumptions . 7 5.1 Obstructions 7 5.2 Transmittance . 7 5.3 Reduction factor for frames, sash bars, etc. . 7 5.4 Dirt 8 5.5 Ref
5、lectance of internal room surfaces . 9 6 Calculation of auxiliary parameters 9 6.1 Effect of rooflight wells 9 6.2 Effect of the shape of rooflights 10 6.3 Effect of finite room dimensions . 10 7 Calculation of the necessary rooflight rough opening area 12 Bibliography . 13 Figures Figure 1 Schemati
6、c overview for the explanation of uniformities g1and g26 Figure 2 Reduction factor keto account for the effects of the light well at different angles of inclination Wand a reflectance of the well walls of S= 0,55 in relation to the well index w 8 Figure 3 Overview of the geometric parameters of a ro
7、oflight well . 10 Figure 4 Corrections a and b to account for the finite room length a and width b in relation to angles aand b, which are given by the ratio of one-half the room length or width to the distance between the working plane and the ceiling 11 Figure 5 Example showing the dimensions nece
8、ssary for determining corrections for finite room lengths and widths . 11 Tables Table 1 Relation between reduction factor k2 and dirt load on the glazing (guidance values) according to DIN 5034-3 . 8 Table 2 Reduction factor k4to account for the shape of rooflights . 10 DIN 5034-6:2007-02 3 Forewor
9、d This standard has been prepared by the Normenausschuss Lichttechnik (FNL) (Lighting Technology Standards Committee). DIN 5034 consists of the following parts under the general title Daylight in interiors: Part 1: General requirements Part 2: Principles Part 3: Calculation Part 4: Simplified method
10、 of determining window sizes in dwellings Part 5: Measurement Part 6: Simplified determination of suitable dimensions for rooflights Amendments This standard differs from DIN 5034-6:1995-06 as follows: a) errors in Equations (5), (7), (16) and Figure 3 have been corrected. b) specifications have bee
11、n revised and brought up-to-date with current developments (e.g. the withdrawal of DIN 5035-1 and DIN 5035-2 and replacement/partial replacement by DIN EN 12464-1 and DIN EN 12665). Previous editions DIN 5034-6: 1995-06 DIN 5034-6:2007-02 4 Introduction Rooflights have been used in flat or slightly
12、sloping roofs for many years to illuminate especially large spaces with daylight. At present, no photometric or physiological-optical requirements on the size of rooflights and their distribution in the roof or ceiling are known. However, the many years of experience in the use of rooflights especia
13、lly in rooms with great depths allow statements to be made regarding the effective dimensioning and arrangement of rooflights. This standard describes a suitable calculation method for this purpose. NOTE The term “rooflight” includes, for example, different types of individual rooflights, continuous
14、 rooflights, and shed lights, including those in sawtooth roofs. 1 Scope This standard is intended to allow a fast, approximate sizing of the appropriate ratio of transparent surfaces to the total ceiling space in rooms with rooflights. The numerous parameters influencing the dimensioning of rooflig
15、hts are largely eliminated by specifying representative default values in Clause 5, making a comparison of various rooflight shapes possible and allowing the approximation of roof constructions that is often sufficient in practice. DIN 5034-3 describes a method for the precise calculation of illumin
16、ation provided by daylight in rooms with rooflights. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includin
17、g any amendments) applies. DIN 5034-3, Daylight in interiors Part 3: Calculation DIN 18032-1, Sports halls Halls and rooms for sports and multi-purpose use Part 1: Planning principles DIN V 18599-4, Energy efficiency of buildings Calculation of the net, final and primary energy demand for heating, c
18、ooling, ventilation, domestic hot water and lighting Part 4: Net and final energy demand for lighting DIN EN 410, Glass in building Determination of luminous and solar characteristics of glazing DIN EN 12464-1, Light and lighting Lighting of work places Part 1: Indoor work places DIN EN 12665, Light
19、 and lighting Basic terms and criteria for specifying lighting requirements DIN 5034-6:2007-02 5 3 Symbols AOL,iarea of i rooflight rough openings =niAA1iOL,OLsum of the areas of rooflight rough openings a room length aOLclear length of rooflight rough opening aSclear length of rooflight well b room
20、 width bOLclear width of rooflight rough opening bSclear width of rooflight well D daylight factor Daverage daylight factor DHsky component of the daylight factor Dmaxmaximum value for the daylight factor Dminminimum value for the daylight factor OLDaverage daylight factor for rooms with rooflights
21、according to practical experience DRinternally reflected component of the daylight factor Eaoutside horizontal illuminance by an overcast sky without obstructions mE maintained illuminance according to DIN EN 12464-1 g1uniformity of the illumination with daylight; DDgmin1= g2uniformity of the illumi
22、nation with daylight; maxmin2DDg = h clear height of room hNheight above the working plane (see Figure 3) hSheight of rooflight well k1reduction factor for frames, sash bars, etc. k2reduction factor for dirt accumulation k3reduction factor for light incidence that is not normal to the surface k4redu
23、ction factor for shape of rooflights kereduction factor for geometry of the rooflight well n number of rooflights w well index Fangle of inclination of the transparent area to the horizontal Wangle of inclination of the wall of the rooflight well to the horizontal a reduction factor to take account
24、of a finite room length b reduction factor to take account of a finite room width aangle given by the ratio of half the room length to the distance between the working plane and the ceiling DIN 5034-6:2007-02 6 bangle given by the ratio of half the room width to the distance between the working plan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN503462007DAYLIGHTININTERIORSPART6SIMPLIFIEDDETERMINATIONOFSUITABLEDIMENSIONSFORROOFLIGHTS 室内 日光 照明

链接地址:http://www.mydoc123.com/p-658239.html